Joinwit JW3213 Series User manual

1
User Manual
PON Optical Power Meter
JW3213 Series
Version:V2.20

1
Contents
Notes ---------------------------------------------------- 2
1.Standard Configuration --------------------------------- 1
2.Overview ----------------------------------------------- 3
3.Technical Specifications-------------------------------- 6
4.Instruction -------------------------------------------- 7
5.Trouble shooting -------------------------------------- 21
6.Maitanance -------------------------------------------- 22
7.Warranty & Servicing ---------------------------------- 22
Appendix I ---------------------------------------------- 24

2
Notes
Icon Meaning:
In this manual will appear some text with the below icon,The meaning as
follows:
Warning:Improper behavior and operation, to prevent any wrongdoing and
harm.
Note:Due to the improper operation may cause harm to the human body or product, so
special note to warn the user.Please make sure that!
Important note:To identify the key information, general notes, noun explanation or
reference information, etc.
WEEE Sigh:This product or component part (s) shall not be considered as a general
garbage dump, please according to your area on waste treatment method for disposal of such
products.
About Battery
This series of products are different types used in power supply or have a different way. There are
disposable alkaline batteries, or rechargeable batteries. Do not mixture
of different types or different capacity of battery, prohibited to charge a
rechargeable battery.
About Storage
When product long-term deposit or do not use, please remove products within the battery stored
separately, in order to avoid battery leakage caused by instrument
damage.
To prevent electric shock, please do not open the product case, must
be the company authorized by a qualified professional personnel for
repair; Do not expose this product in the rain or damp environment, so
as to avoid fire or click on the occurrence of danger!
Due to the laser can cause the big harm to eyes,please do not look
directly into the laser output when you use the tester.

3
Chapter 1 Standard Configuration
Please refer to the following models corresponding to the standard
configuration, check whether your product accessories is complete, if lack of
any items, please contact the dealer as soon as possible!
Model
JW3213 Series Pon Optical Power Meter
Items
Title
Quantity
1
JW3213 tester
1unit
2
User Manual
1pc
3
USB
1pc
4
Soft CD
1pc
5
1.5VAA Battery
3pc
Chapter 2 Overview
JW3213 Series PON Optical Power Meter target at the FTTx application and
maintenance. This power meter is able to simultaneously test and estimate the
signals of the voice, data and video. It is an essential and ideal tool for the
construction and maintenance of the PON projects.
Features:
(1).It can experiment at Voice, data and video signal synchronous measurement and
display on BPON/EPON/GPON.
(2)Providing simultaneous measurement for all three wavelengths on the fiber (1490nm,
1550nm,1310nm )
⑶Used in Burst mode measurement of 1310nm upstream.
⑷.Use the software connect with PC, setting the threshold, data transfer, and calibration
the wavelength.

4
⑸.USB communication port enables data transfer to a PC.1000measurement items can
be saved in JW3213 PON power meter or computer for data review.
⑹ . With optical power meter module,include850 、1300、1310、1490、1550、
1625sixs(JW3213AP,JW3213Awithout850nmwavelength); With visual fault locator
module
(JW3213andJW3213AV)
⑺.Optical power meter and VFL with one port.(onlyJW3213A)
⑻.Optional Chinese/English display.
⑼.Offers up to 10 different threshold sets in total,Three status LEDs represent different
optical signal conditions of Pass, Warn and Fail respectively.
⑽.10 minutes Auto-off function can be activated or deactivated
⑾.Good key design,high sensitivity, greatly reducing the volume and weight of the tester.
⑿.Different models corresponding to different function, according to own use to
choose .
Chapter 3 Technical Specifications
3.1 PON module:
PON module:
JW3213
JW3213
A
JW3213
AV
JW3213A
P
1310 upstream measurement
Pass Zone(nm)
1260nm~1360nm
MeasurementRange(dBm
)
-40dBm~+10dBm
Input power(max)
15dBm
Isolation@1490/1550(dB)
>40dB
Burst mode measurement
error
<±0.5dB
1490 downstream measurement
Pass Zone(nm)
1470nm~1505nm
MeasurementRange(dBm
)
-40dBm~+10dBm
Input power(max)
15dBm
Isolation@1310/1550(dB)
>40dB
1550 downstream measurement
Pass Zone(nm)
1535nm~1570nm

5
MeasurementRange(dBm
)
-40dBm~+20dBm
Input power(max)
25dBm
Isolation@
(1310/1490nm)
>40dB
Measurement Accuracy
Connatural
uncertainty(dB)
±0.5dB
Linearity(dB)
±0.1dB
Passing through insertion
Loss(dB)
<1.5dB
General Information
Detector Type
InGaAs
Optical Connector
FC/SC/ST Interchangeable/2.5 universal
adapter
Fiber Type
SM 9/125um
Measurement Unit
dB/dBm/xW
Resolution (dB)
0.01dB
Operation Voltage(V)
DC 3.3V~5.5V
Power Supply
3pc1.5V battery
Continuously Operation
time (h)
PON:
90h
PON:90h
OPM:100h
VFL:50h
PON :
90h
VFL:50h
PON:90h
OPM:100h
Operation
Temperature(℃)
-10℃~60℃
Storage temperature(℃)
-25℃~70℃
Weight(kg)
423g
425g
424g
424g
Note: The operation time of the battery are all for the instrument that do not turn on
backlight, if the backlight turn on the operation time will be shorted.
3.2 Normal Optical Power Meter Module::
Normal Optical Power
Meter
JW3213②
JW3213A
JW3213AP
Measurement Accuracy

6
Connatural
uncertainty(dB)
None
±0.5dB
Linearity(dB)
±0.1dB
Measurement
Range(dBm)
-70dBm~+6dBm
General Information
Measurement Unit
None
dB/dBm
Resolution (dB)
0.01dB
Calibration
Wavelength(nm)
1300/1310/
1490/1550/1625
850/1300/1310/
1490/1550/1625
Detector Type
InGaAs
Optical Connector
FC/SC/ST Interchangeable/2.5 universal
adapter
②:JW3213do not have the OPM module
3.3VFL Module:
VFL
JW3213③
JW3213A
JW3213AV
Output power
None
>0.5mW
Wavelength
650nm
Optical
Connector
FC/SC/STInterchangeable/2.5
universal adapter
Fiber Type
SM/MM
③:JW3213 without VFL module.

7
Chapter 4 Instruction
JW3213 / JW3213A two models are different between functions and the
form, detailed in this chapter, please check carefully.
1.Describtion
1- OLT/VIDEO:1490nm/1550nm Down Stream
2- ONT:1310nmUp Stream Port(1310nm)
3- VFL or OPM Port
4- Display
5- ONT1310nmUp Stream Port LEDs
6- OLT1490nm/1550nm Down Stream LEDs
1
2
3
4
5
6
7
8
11
9
10
12
13
14

8
7- Video signal LEDs (1550nm)
8- AUTOpower/off key
9-UPIn the first interface, switch visual fault location model(VFL)
10- ENTER: Confirmation the function selection and saving the data.
11- MENU: PON/CW Power meter module Option
12- DOWM,In the first interface,Switch betweenVFL in continuous light
(the CW) and pulse light (HZ)
13- CANCEL:Function cancel
14- USB PORT
④:Only JW3213A and JW3213AV up/down keys for VFL function
PON Online test connection diagram
OLT PON Interface optical power test configuration diagram
OLT
ONT
……
Data Networks Analyser
IXIA/Smartbits
Fiber
Fiber
Optical Splitter

9
ONT The sensitivity test configuration diagram
Data Communication
Run the CD,install USB driver software CP210x_VCP_Win2K_XP_S2K3.exe.
Then install dotNetFx40_Full_x86_x64.exe.
Connect JW3213 PON power meter to the computer’s port using the provided
USB cable,Open the software as shown in below figure:
Upload the data
OLT
ONT
……
Data Networks Analyser
IXIA/Smartbits
Fiber
Optical Splitter
1490nm
1310nm
Lamda Multiplexer
Variable Optical
Attenuator

10
(1)Open the JW3213PON power meter,first of all click “connect”,connect
JW3213PON power meter to the computer(Click“English”to set the language
of the operation interface to be English )
(2)choose “Upload Data”,click “Upload Test Data”sign,the saved data can
be read on the computer, and saved as a file format.
(3)click the“Delete Test Data” button or“Clear Test Data”to delete the data.
Threshold Setting:
Click“Upload threshold value”icon to read the threshold.

11
From the toolbar, select “Threshold Set”, and right click the Threshold to
type or modify the threshold value.
Calibration
Choose “Calibration”tab, the user can perform user self-calibration
operation also can choose “Factory Reset”mode. For example, the
current optical power at 1310nm is -10dBm, type -10dBm in the text box
of input standard power, and click Calibration tab, then finished the
calibration operation at 1310nm wavelength.
Power ON/OFF
1.Power ON
Press for about two seconds to make the unit power on,Enter
into the PON power meter function , the unit displays as shown in below
figure:

12
As shown in above figure, the LCD will display simultaneously three
wavelengths of 1310nm upstream measurement and 1490nm,1550nm
downstream measurements. When optical signal is present under test,
the optical channel will display power levels in dBm, when optical signal
is not available, then the optical channel will display “LOW”. “ ”indicates
10 minutes auto-off function is activated.The unit will turn itself off after
10 minutes of idle time. Press to close 10 minutes auto-off.
2.Power Off
Press key for about two seconds,to turn off the unit.
PON Power Meter module
PON power meter can simultaneously measure the PON network upstream signals
of 1310 nm, 1490 nm downstream data signal and descending video signal output power
of 1550 nm
After open the instrument, Press to enter into menu operation, Press
“ ” to exit
Press“ ”or“ ”to choose the following settings, and press
“”to choose the function.

13
Use“or ”to choose the required threshold value,(The
thresholds rang and name have already set in the software, and also
download to the instrument, please check with the user manual of Chapter
6 data communication), For example choose threshold and name it as “a”
and press“ ”.
Press“ ” back to the testing menu.
Clean the tested optic cable, connect with OLT/VIDEO port and ONT port,
(SC type connector), noted with the optic adaptor type, the optical adaptor

14
will be break, and the tested value will be faulty if the un-matched adaptor
connected
Pay attention to the type of the measured optical fiber connectors, does not match the
type of access instrument, may damage the instrument output optical fiber connector,and can not
get the true result.
1310nm,upstream, 1490nm, 1550nm downstream, and 3 wavelength measurement at the same
time.
Eg.: The selected threshold name is “a”(-10dBm,-20dBm,-30dBm). The
measured result displayed: -11dBm (Optical power) at 1310nm upstream
measurements shown in above figure, as it is within -10dBm (Pass
threshold)~-20dBm(Warning threshold), therefore, it means the optical
signal in Pass status and the LED at 1310nm will light up with green color:
If the measured result is between -20~-30dBm, it means the optical signal
in Warn status and the LED at 1310nm will light up with yellow color which
means the optical signal may got problems but still can be used; If the
measured result is out of the range of thresholds, i.e greater than -10dBm
or smaller than -30dBm, then it means the optical signal got problems, the
LED at 1310nm will light up with red color. The same process be used at
1490 and 1550nm wavelengths.

15
Press“ ”, there will displaying saving on the screen, check with the
upper pic. The data recording series No.is 0002. press“ ” saving, and
“ ” for cancel, and the saving recording can be checked in the “data
view” under “historical data” Menu.
After finish the testing work, keep the connect port clean, so cover the
dusty-cap once finish the work.
Instructions for Normal Optical Power Meter Function⑤
Press button to open the instrument, use “ ” button and
;to choose the Optical Power Meter measurement, then press
“ ” to enter into the selected function. or Button in this
case, is to choose the wavelength. Instrument only provide the test of 850nm、
1300nm、1310nm、1490nm、1550nm、1625nm,display “-70dBm”when without
light.
Take 1310nm measurement for example:
Connect with the tested optic fiber
Clean the optic Fiber end-face, and connect with the PIN port on the
instrument (SC/ FC/ST adaptor), noted with the type of the optic fiber adaptor,
the non-matched connecting will make the damage of the connector on the
instrument and also make the faulty of the measuring result.
E.g.: 1310nm measurement, after connect with the optic fiber, it will displaying
-20dBm, press“ ”, set the -20dBm as the reference value, and it will also

16
display relative value (dB), see as following:
In order to get the loss between the two measurements, do another time
testing under the first relative output power. The relative value will be
calculated automatically. For example the second time testing of 1310nm
output power is -35dBm, the relative output power will be -15dBm.(relative
output power=absolute output power-reference value -15dBm=-35.00dBm-
(-20.00dBm)see as following:
After finishing testing, cover the dusty cap to keep the optical connector
port to be clean.
⑤:JW3213&JW3213AVwithout this function.
VFL module⑥
During the event or break point checking of the short distance optic fiber
and pigtails we can use the VFL function.
First of all, Clean the optic Fiber end-face, and connect it them the VFL
port (FC adaptor), after open the instruments, press “ ” to activate this
function, then can see the visual laser at the breaking point or the end of the
pigtails. Press “ ” to shift the CW and the Hz wavelength. And press
Ref
Absolute value
Relative value

17
again to close this function.
⑥:JW3213&JW3213AP without this function.
Other function instruction:
PON Power Meter:
Relative output power measurement:
As per requirements of measurement to select the different wavelengths
and Ref settings, relative power=testing value-Ref value. Press
or to select the different wavelengths, Press“ ” to change
the Ref value as shown in below figure
Threshold Selection
It offers up to 10 different threshold sets in total. There are three status LEDs in
the front panel and each light indicator has three conditions of colors which
represent different signal status as below:
Green---Represents Pass
Yellow---Represents Warning
Red----Represents Fail
Behind“ThreshSel”displays selected threshold setting order number from 1~10,
and behind “Name”displays selected threshold name, press or
REF
RELATIVE
VALUE

18
to select the corresponding shresholds. With using JW3213.exe software to
modify the values range and names of thresholds (Detailsas explained in term
5-Data Communication.)
⑦:Threshold Selection just can be use English or figure,can not use Chinese.
Switches of measurements units
Measure the output power of the fiber use dBm or Xw, Press “ ” with
and to choosethe measurements units, press “ ” to
exit and cancel the current operation as shown in below figure。
Switches of language
There are two language English and Chinese to Choose, Press“”
and to select “Language” option, Press “ ” to exit
Status
LEDs-JW3213

19
and cancel the current operation.
Time setting
In item 5 have “Time Setting”Press and select the “Time
Set”option, and press to change year-month-date-time
respectively as shown in below figure,use and to change
the digits. After setting, press “ ” to confirm.Press “ ” to exit
and cancel the current operation.
This option is designed to review and delete saved measurements data.
Press “ Menu” to enter into menu operation, using with and
to highlight “History Data” option. There are three options in
History data:
This manual suits for next models
3
Table of contents
Other Joinwit Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Tektronix
Tektronix TPS2PWR1 user manual

twintex
twintex LCR Series Operation manual

McCrometer
McCrometer Field Mag 3000 Quick start installation guide

Agilent Technologies
Agilent Technologies U2300A Series user guide

FW Murphy
FW Murphy TDX6 Installation and operation instructions

Nikon
Nikon Forestry Pro II instruction manual