The shipping crate contains the following items:
• Electromagnetic meter assembly with
grounding wire attached
• Converter cable (attached to meter)
• Signal converter
• Grounding rings (anged meters only)
• Ground wires (2) (anged meters only)
• User manuals for both the sensor and
converter
When uncrating the Field Mag, any damage due to
rough or improper handling should be reported
to the transportation rm and McCrometer. If for
any reason it is determined that the unit or parts
of the unit should be returned to the factory,
please contact McCrometer for clearance prior to
shipment. Each unit must be properly crated to
prevent any further damage. The factory assumes
no responsibility for equipment damaged in
return shipment due to improper packaging.
1. Check Shipping Crate Contents
2. Check Serial Numbers
3. Pipe Run Requirements
4. Sensor Position and Location
The converter and sensor are supplied as a
matched system. Verify the meter serial numbers
on both the converter and sensor match. This will
insure a properly calibrated system.
The tag on the side of the converter has the
converter model number, the converter serial
number and the meter serial number, which is
calibrated to the converter. An example is shown
below.
The meter needs to be located a minimum
distance before and after ow disturbances,
such as elbows, pumps, partially opened valves,
and changes in pipe diameter. The uneven ow
created by these obstructions can vary with each
system.
The minimum distance is measured in pipe
diameters(D).Toensureaccuracy locatethe sensor
upstream and downstream of ow disturbances
as follows:
2D upstream / 1D downstream
IMPORTANT
Verify the meter serial numbers on both
the converter and sensor match. This will
insure a properly calibrated system. The meter
serial number is located on a plate on the body
of the sensor, and the converter serial number
and the meter serial number are located on a
label on the side of the converter. Insure the
meter serial number on the sensor and the
converter tags match.
Pipe Diameters
For proper accuracies any 90 or 45 degree elbows,
valves, partially opened valves etc. should be
placed not closer than two pipe diameters
upstream and one pipe diameter downstream.
Flow Direction
It is very important to install the ow meter relative
to the ow of the water. There is a sticker on the
Field Mag that indicates the direction of ow.
Sensor Orientation
The following installation recommendations
should be followed (see next page):
30126-62 Rev. 1.0 | 02JAN2024
Page 2