Installation Indications, functions and options MessagesOperation and function
2.2 Electrical connection
WARNING! Electric shock!
Upon opening the housing, live parts are exposed!
ÎAlways disconnect the device from power supply before
opening the housing!
ATTENTION! ESD damage!
Electrostatic discharge can lead to damage to electronic compo-
nents!
ÎTake care to discharge properly before touching the in-
side of the device!
Note:
Connecting the device to the power supply must always be the last step
of the installation!
Note:
It must be possible to disconnect the device from the mains at any time.
ÎInstall the mains plug such that it is accessible at any time.
ÎIf this is not possible, install a switch that can be accessed.
Do not use the device if it is visibly damaged!
4HEPOWERSUPPLYOFTHEDEVICEMUSTBEx6^x(Z!TTACHmEXIBLE
cables to the housing with the enclosed strain relief and the corresponding screws.
The controller is equipped with 1 semiconductor relay to which a load such as a
pump, a valve, etc. can be connected:
• Relay 1
18 = Conductor R1
17 = Neutral conductor N
13 = Grounding terminal
The mains connection is at the following terminals:
19 = Neutral conductor N
20 = Conductor L
12 = Grounding terminal
The terminals marked PWMARECONTROLOUTPUTSFORAHIGHEFlCIENCYPUMP
7 = PWM -
8 = PWM +
Speed control of a HE pump is possible via a PWM signal.The pump has to be con-
nected to the relay as well as to the PWM output of the controller. Power supply
to the HE pump is effected by switching the relay on or off.
VBus®
IP 20
T2A
220 ... 240 V~
50-60 Hz
Temp. Sensor Pt1000
S1 S2 S3 PWM R1VBus
1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 20
N N L
R1 1 (1) A 220 ... 240V~
DeltaSol BS HE
mains terminals
Fuse
load terminals
sensor terminals grounding
terminals
Connect the temperature sensors (S1 to S3) to the corresponding terminals
with either polarity:
1 / 2 = Sensor 1 (e. g. collector sensor)
3 / 4 = Sensor 2 (e. g. store sensor)
5 / 6 = Sensor 3 (e. g. store sensor top)
2.3 Data communication / Bus
The controller is equipped with the VBus®for data transfer and energy supply
to external modules.The connection is to be carried out at the terminals marked
VBus (any polarity).
One or more VBus®modules can be connected via this data bus, such as:
• DL2 Datalogger
• DL3 Datalogger
Furthermore, the controller can be connected to a PC or integrated into a network
via the VBus®/USB or VBus®/LAN interface adapter (not included).
Note:
More accessories on page 20.