Joyonway PB554 User manual

Simplified operation
instruction
PB554
V1.0

If pump 1 is single speed pump, then the key will be used to control the on and
off of pump 1. If pump 1 is double speed, then keep pressing the key, it will
switch from low speed pump, high speed pump to off. The sequence is low speed
pump-> high speed pump-> off.
Short-cut key pump 1:
Light has two modes. In on/off mode, pressing the key can turn on and off the
light. In RGB mode, it has 9 statuses of auto color change, red, green, yellow,
blue, purple, cyan, white and off. User can switch among these statues by
pressing the key.
Shortcut key light:
Press this key to turn the main interface upside down. And the direction of
navigation key will be changed accordingly.
Short-cut key ofScreen Invert:
WARNING
1. Please connect power strictly accoding
to the SPA power data plate.
2. Please do not turn the SPA power on
until the water reaches water level line
inside the tub.
WARNING
Please set time and date
before using the SPA
control system.
(pump) jet 1
light
navigation key (down)
navigation key (up)
navigation key (left)
navigation key (right)
confirm
Screen Invert 1

2
Press “ ” in the main interface to go to the function operation interface.
In the function operation interface, the icon will be shown in bigger size if the
cursor is on it. Press“ ”to move the cursor to the“ ”. Press “ ”to
move the cursor to the selected (bigger size) icon.if cursor selects “ ”,
press“ ”to go back to the main menu.
In the function operation interface, press“ ”
or“ ”to move the different function icons to
the middle of the screen(to select the icons). The
corresponding name and working status of the
function will be showed in the upside of the
screen, press“ ”to switch the working status
of the controlled function.
Move the cursor to setting icon“ ”. Press“ ” to enter into set interface.
In the set interface, the character will be highlighted if the cursor is on it. Press
“ ” or“ ” to move the cursor location. Press“ ” to enter into the
second level interface of the chosen function or change its status.
When the manual heating function is started, there will be a heating icon“ ”
added in the function operation interface. User can start heating function in the
function operation interface manually. When the manual heating function is
turned off, the icon will disappear.
Set interface:
Manual Heating:
When the green cursor is on“ ”or“ ”,
press“ ”to set the time period as “on” or
“off”. Press“ ”to enter into time setting. In
time setting, press“ ” to move the cursor.
Press“ ”and“ ”to operate time setting.
Press“ ”and“ ” to exit the time editing
and the cursor will move back to the left side.
Heating time
When the time setting is finished, press“ ”to return and store the setting.
1 2

Manual Cpump
When the manual cycle pump is started, there
will be a cycle pump icon ” ” added in the
function operation interface. User can start
cycle pump manually in function operation
interface. The icon will disappear when the
manual cycle pump function is turned off.
When the system is set in timing water cycle
mode, its on/off and time setting are the same
as the time setting of timing heating.
Mode
PB554 control panel can store four different
modes. Mode can store the states of pump,
blower, ozone, heater, and backlight brightness.
How to store the setting: In“ ”, move
the cursor to the items need to be saved and
press“ ”. If the square on the right side of
the item is solid, then it indicates the current
mode is stored.
How to select the mode stored: In“ ”,
press“ ”in turn to select the stored the
modes.
>Mode
Temp. unit
Temperature unit can be set as ℃
or ℉ .
>Mode
Filter time
Attention:
all the time setting is based on the system time. So user need to keep the system
time accurate before operate the time period setting.
3

Auto lock
The auto lock starting time can be set as “off”, 30S“, “1 min” or “3min”.
When the lock function is started, press continuously ” ” for 3S till “Auto
lock” disappears, and the panel is unlocked. in the function operation
interface.
Brightness
Backlight brightness range is 1-16.
Date & time
In ” ”, date and time can be
set. If the control system is off power, the
correct time setting can be kept for a few days.
>Date & Time
Ozone
OZone has two modes: auto and manual
Ozone can be set as auto start or manual start.
In manual start mode, there will be an icon
“ ”added. User can star t the ozone
generator manually in the function operation
interface.
Temprature setting
The temperature setting range is 50 ℉ to 104 ℉ (10 ℃ to 40 ℃). In Set->
Temperature, press“ ”and“ ”to set the value of the temperature. The
value will be automatically stored after exiting the menu.
4

When some problems occur requiring users' attention, the alarming information will be
displayed on the control panel. If several problems occur at the same time, the
alarming information will be displayed in turn. Below is an example:
Below is the detailed description of the control system alarming information:
Alarming information
display position
Temperature sensor disconnected
Control system detects the temperature
sensor is disconnected. Please check the
connection of temperature sensor to the
system. And replace it with a new one if
necessary. ower the system. If the problem
remains, please contact technical support.
Temperature sensor short circuit display
Control system detects the temperature
sensor is short circuited. Please check the
temperatu re sensor and its connection .
Replace it with a new one if necessary.
F1:TEMPERATURE SENSOR
DISCONNECTED
F2:TEMPERATURE SENSOR
SHORTCIRCUIT
Temperature is too high
Reason: the system detects the temperature
sensor's temperature being too high. This can
happen when the heater is on, and there is no
water in the heating pipe or the water flow is too
slim. Action: please ensure there is water in the
SPA tub. If the problems occur frequently, please
contact technical support.
F3:TEMPERATURE IS
TOO HIGH
5

Auto reset thermo switch open
I t i n d i c a t e s t h a t t h e h e a t i n g p i p e
temperature is too high. This may happen
when heater is started and there is no water
in heating pipe or water flow is too slim.
Action: Please ensure there is water in the
SPA tub. If the problem occurs frequently,
please contact for technical support.
Manual-reset thermo switch open
It indicates the heating pipe temperature is
too high. Please contact technical support.
F6:MANUAL-RESET
THERMOSWITCH OPEN
Eeprom (main Board Memory) Error
Please disconnect the power and wait for 10
se c o nds to rep o wer the syste m . If th e
problem remains, please contact technical
support.
F8:EEPROM(MEMORY)
ERROR
F5:AUTO-RESET
THERMOSWITCH OPEN
Temperature is too low
Control system detects temperature sensor's
temperature being too low. Please pay attention
to freezing problem.
F4:TEMPERATURE IS
TOO LOW
F9:SYSTEM SETTINGS
ERROR
System setting error display
Reason: After power connection, the system
reads the system configuration verification to be
incorrect from EEPROM (main board memory).
Action: please disconnect the power and wait for
10 s ec on ds to rep ow er the system. I f th e
pr ob le m remai ns , pl ea se cont ac t t ec hn ic al
support.
6

Shenzhen Joyonway Electronics & Technology CO.,LTD.
ADD:4F,Section C,Building B6,China Merchants Guangming Science Park,
Guanguang Road 3009,Guangming New District,Shenzhen, China
TEL +86 (755) 26010705 26010708:
Sale Tel 26554068 26010859:+86 (755)
Oversea sales (+86) 13925211653:
China sales (+86) 13602626203:
FAX 26010704:+86 (755)
P.C. 518106:
WEB www. .com:joyonway
E-mail sale1@ .com:joyonway
Oversea TEL: (+86) 13510031501
E-mail: service1@joyonway.com
China TEL: (+86) 13510031581
AFTER-SALES SERVICE:
Table of contents
Other Joyonway Control System manuals
Popular Control System manuals by other brands

Next Wave Automation
Next Wave Automation Digital Duplicator manual

Veeder-Root
Veeder-Root TLS-300 Operator's quick guide

Uponor
Uponor Climate Control-Multifunction installation guide

Avanza
Avanza aSL.1503 aSmart Lite installation manual

Exhausto
Exhausto VEX200 series Basic instructions

Auper
Auper Eclipse 784 B Quick user guide