JP AG Series User manual

JP FLUID CONTROL
AG-5 series
Electric actuator
1
AG-5 series actuator www.jpfluidcontrol.com
Model
AG-550-A
AG-550-B
Response time
13s
13s
Voltage
100-230V AC ±10%
24 AC/DC ±10% (AC/DC automatically
detected)
Utility frequency
50/60Hz
50/60Hz
Torque (Max.)
50Nm
50Nm
Current (Max.)
0.45A
1.2A
Current (Nom.)
0.13A
0.25A
Resolution
0.6°
0.6°
Housing material
Powder coated aluminum
Powder coated aluminum
Seal material
NBR
NBR
Ambient temperature range
-10°C to max. 50°C
-10°C to max. 50°C
ISO 5211 flange
F03, F05 and F07. 9, 10 and 12mm
thread depth respectively
F03, F05 and F07. 9, 10 and 12mm thread
depth respectively
Duty cycle
S2 30Min
Properties
14 x 14 Star connection
IP67 weather proof rating for housing
Manual override lever for safety-control
Cable entry: 2 x ½” PF
Two auxiliary limit switches for position feedback
1W space heater
101,6 x 120,6 x 128,6 mm L x W x H
•Torque 50Nm
•Open/Close 13s
•ISO 5211 F03/F05/F07
•Manual override
•Position indicator
•Position feedback
The AG-series is a range of
high-quality quarterturn actuators
to control the position of valves
with an ISO 5211 flange of type
F03, F05 and F07. The actuator
can deliver 50Nm in a fast and
smooth operation. The dome
indicator provides a clear visual
inspection of the valve position.
The actuator features a manual
override and 2 auxiliary limit
switches for position feedback.
Figure 1. AG-5 Actuator.

JP FLUID CONTROL
AG-5 series
Electric actuator
2
AG-5 series actuator www.jpfluidcontrol.com
Safety Instructions
General Safety Instructions
Please read the safety instructions carefully before installation, use or maintenance.
•The actuator only complies protection class IP67 (according to IEC 60529), if the device is properly
connected.
•Improper use may be hazardous.
•This product is not a safety device and may not be used as such.
•Never put your hands/body parts or other objects into ports of mounted valves. The rotating motion can
cause serious injuries or damages.
•Correct transport, proper storage and installation, and proper use and maintenance, are essential for
reliable and error-free operation. The product may not function properly as a result of dirt, wear, damage
(for example, by dropping) or improper use. Therefore, the product should not be used in applications
where a malfunction can cause danger or damage.
•Check the compatibility of the valve, temperature and other operating conditions with the materials and
specifications of the product. It is the responsibility of the user to select the right product for the
application.
•Never exceed the limits for torque, temperature or voltage as indicated on the product and/or in the
technical documentation.
•It is not allowed to change the construction of this device.
•Beware of electric shock, burnings or other injuries when working with electrical equipment.
•It is recommended to install the actuator in a dry environment. In moist environments, make sure that no
moisture can penetrate the actuator. Make sure the actuator is not in contact with or in the vicinity of
flammable materials. Ensure that the product is protected from frost. Frost may damage the product
and/or block the moving parts, causing the electric ball valve to malfunction.
•Maintenance may only be performed when the system is not pressurized, electrically disconnected and
cooled down.
•Turn off the power supply before performing any work on the actuator to prevent the risk of electrical
shock and to prevent activation of the actuator.
•The product is only safe when properly installed and operated by qualified persons.
•Ensure a controlled commissioning after installation or maintenance.
•Improper installation can permanently damage the actuator or lead to dangerous situations.
Compliance
The actuators are CE marked and comply with the LVD Directive (2006/95/EC) and EMC Directive
(2004/108/EC), provided that the cables and connectors are properly connected.
Intended Use
The AG-5-actuator can be applied to rotary type valves that require quarter-turn operation, such as 2-way or 3-
way ball valves and butterfly valves. Common applications include ventilation, heating systems, solar water
heaters, irrigation systems and industrial equipment.
Duty Cycle
The AG-5-series can be used for continuously for 30 minutes (S2 30 min according to IEC 60034-1), after this
period the actuator must cool down to ambient temperature. High loads and long operating times may reduce
the lifespan of the actuator.

JP FLUID CONTROL
AG-5 series
Electric actuator
3
AG-5 series actuator www.jpfluidcontrol.com
Identification
The following figure shows an example of the type plate of the actuator. Observe the specifications and the
connection diagram before using the product.
Components
Figure 2: Components of the AG-5-Series Actuator.
Working conditions
It is recommended to install the actuator in a dry and ventilated environment to prevent overheating and entry
of moisture. Moreover, the ambient temperature should lie in the operating temperature range of -10 °C up to
50 °C. The actuator may only be used to control valves that require a maximum torque of 50Nm. Please note
that the operating torque strongly depends on medium type, pressure, temperature and period of standstill.
Break away torque can increase the maximum torque requirement!

JP FLUID CONTROL
AG-5 series
Electric actuator
4
AG-5 series actuator www.jpfluidcontrol.com
Step-by-step installation guide
Do not use sharp objects while opening the box. Make sure the actuator is disconnected from
any electricity before following the installation guide.
1
Carefully open and unpack the box.
2
Loosen the four Captive Bolts of the Terminal Block chamber (Figure 3) and the four captive bolts of
the housing cover (Figure 4).
Figure 3: Captive bolts to remove.
Figure 4: Removing the cable glands.
3
Remove the terminal block chamber cover, the housing cover and the cable glands.
4
Insert a suitable cable through the Cable Gland.
5
Remove the terminal block from the Terminal block chamber.
The wires should be connected to the terminal block (Figure 1), according to the wiring
diagram (Figure 5 a/b).

JP FLUID CONTROL
AG-5 series
Electric actuator
5
AG-5 series actuator www.jpfluidcontrol.com
Electrical wiring
Figure 5: Wiring diagram (3 point connection) for the AG-550 models. The minimally required wiring for operation is
shown in the green box.
6
AG –550 –A (100-240VAC): Connect terminal 2 to the power supply, connecting terminal 4 to the
power supply closes the actuator, connecting terminal 5 to the power supply opens the actuator.
AG –550 –B (24V AC/DC): Connect terminal 2 to the positive terminal of the power supply.
Connecting terminal 4 to the negative terminal of the power supply closes the actuator, connecting
terminal 5 to the negative terminal of the power supply opens the actuator.
Never use the piping to ground the electrical equipment.
Always connect the ground, which is provided with a residual current device at voltages above 50 volts.
7
Connect the ground to terminal 1 (Figure 5a & b).

JP FLUID CONTROL
AG-5 series
Electric actuator
6
AG-5 series actuator www.jpfluidcontrol.com
Feedback (optional)
Always apply a load (max. 5A) in the feedback circuit to prevent permanent damage. Always apply
the correct polarity/phasing. The limit switches share a common source, do not use different power
supplies on both limit switches at the same time. Terminal 7, 8, 9 & 10 must have the exact same
polarity, voltage & frequency when both are being used.
8
AG-550-A/B: The position of the limit switches can be measured by the terminal pairs 8&10 (closed) and/or
9&10 (open).
Limit switch closed position (pair 7&10): Connect terminal 7 to a signal indicator that is connected to a
load and connect terminal 10 to the same load.
Limit switch open position (pair 9&10): Connect terminal 9 to a signal indicator that is connected to a
load and connect terminal 10 to the same load
Mounting
In order for the mechanical indicator the show the correct position of the valve, the actuator
and the valve have to be aligned. Hence, both should be either in the open or in the closed
position.
10
Align the position of the valve and the actuator. That is, open or close both the actuator and the valve
The actuator may be installed in any position, but it is recommended to install the actuator in a
vertical position, with the position indicator facing upwards. This reduces the probability of moisture
entering the actuator. When the electric ball valve is mounted at an angle, it is recommended to
deviate maximally 90° from the vertical position. Ensure that drops cannot slip along the cable and
enter the actuator. See figure 8 for a visual explanation.
The actuator can be mounted to valves with a flange according to ISO 5211 type F03, F05 or F07.
For valves with a shaft of 9x9mm or 11x11mm, an enclosed adapter can be used. The valve must be
fixed to the actuator by four bolts of M5 (type F03), M6 (type F05) or M8 (type F07).
11
Mount the actuator to the valves with the appropriate flange.
Play between actuator and valve may damage the valve or the actuator and/or reduce its
performance.
12
Remount the Terminal Block chamber cover and the housing cover with the Captive Bolts (figure 3).
Figure 8: Mounting angle actuator and ISO 5211 mounting flange.

JP FLUID CONTROL
AG-5 series
Electric actuator
7
AG-5 series actuator www.jpfluidcontrol.com
Actuator Setting and Configuration
Manual override
Always disconnect the power supply before using the manual override. Do not use excessive
force when shifting the lever and lever wheel to prevent damage.
1
Shift the lever on the bottom of the actuator from “auto” to “manual” to set the actuator to manual
override, a small “wiggle” of the lever wheel might be necessary to shift the lever (Figure 9).
2
Fold the gripping rod from the lever wheel (Figure 9).
Figure 9: Manual Operation.
3
Rotate the lever wheel until the actuator has reached the desired position.
Make sure the lever wheel is disconnected from the gears when electrically operating the
actuator (lever at “auto” position).
4
When finished, shift the bottom lever back to the original position and wiggle the lever wheel
until a click is heard, this is to couple the gears to the motor. Test to see if the gear is re-coupled
to the motor by turning the lever wheel and inspecting the valve position. If the valve does not move
the gears are re-connected to the motor. Fold the gripping rod back in the lever wheel.

JP FLUID CONTROL
AG-5 series
Electric actuator
8
AG-5 series actuator www.jpfluidcontrol.com
Limit Switch Adjustment
The limit switch cams can be adjusted to the desired angle. The standard setting is such that ball valves are
fully closed or fully opened. For special applications the cam position may be altered by loosen the locking bolt
(6), adjusting the cam to the right angle and locking the locking bolt again.
The angle may be altered only for a few (<10) degrees since the actuator has a limited range.
Disposal
The removal of the product should be performed in accordance with the applicable laws. Keep in mind the
media that are still present in the valve.
This manual can be downloaded from www.jpfluidcontrol.com. Modifications reserved. This document has been prepared with
great care. JP Fluid Control assumes no responsibility for any errors that may appear in this document. No rights can be derived
from this document.
Component
F I
1
Close Limit Switch
2
Auxiliary Close Limit Switch
3
Auxiliary Open Limit Switch
4
Open Limit Switch
5
Close Limit Switch Cam
6
Locking M4 Bolt
7
Open Limit Switch Cam
Figure 10: Limit Switch Adjustment.
1
2
3
4
5
6
7
This manual suits for next models