manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. K-PO
  6. •
  7. Measuring Instrument
  8. •
  9. K-PO RS-101 User manual

K-PO RS-101 User manual

This manual suits for next models

6

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTRUCTION MANUAL
INTRODUCTION
This SWR & POWER meter is a highly accurate RF meter for measuring Forward/Reverse Power, and VSWR
Main Features
1. Large meter display for ease of reading
2. Forward RF power readings (switchable to indicate either average power or Peak Envelope Power [PEP]
for SSB and AM transmitters)
3. Reverse RF power reading
4. VSWR ratio
5. Illuminated meter
6. Convenient control layout for ease operation
SPECIFICATION
MODEL RS-101 RS-102 RS-402 RS-502
Frequency Range 1.8 - 60 MHz 1.8 - 200 MHz 125 - 525 MHz 1.8 - 525 MHz
Power Range 0 - 3 KW
Power Scale 30/300/3KW
Maximum Power 3 KW
Minimum Power for SWR
Input/Output Impedance
Input/Output Connectors
Insertion Loss
Testing Function
Dimension (W/H/D) mm
Weight (Net) 780 g 790 g 800 g 950 g
Accessories
KBC import / export, Argonstraat 6, 6718 WT Ede, The Netherlands
www.k-po.com
Accuracy Low Range (PEP) +/- 15%
Accuracy High Range (PEP) +/- 10%
SWR/WATT METER
Model : RS-101, RS-102, RS-402, RS-502
0 - 200 W
5/20/200W
200W
(AVG) +/- 10%
(AVG) +/- 5%
1 W
190 x 85 x 135 mm
Operation Manual, 13.8 DC Wire
50 OHM
M (N option for RS-502)
Less than 0.1 dB
Fwd/Rev Power, PEP, SWR
<FRONT PANEL> <FRONT & REAR PANEL>
1. Meter Display : Indicates FWD/REV power in watts and VSWR ratio
2. Function Switch : Select FWD/REV power, SWR SET, and SWR
3. Range Switch : Selects RF power range of 5/20/200W, 30/300/3KW
4. SWR SET Knob : Sets full scale deflection when measuring VSWR
5. AVG/PEP knob (elliptical push button) : Selects Average or PEP RF
Power readings
<REAR PANEL> 6. Meter Zero Adj.: Mechanical adjustment for meter needle
7. TX Connector : Coax connector to transmitter 50 ohm RF output.
8. ANT Connector : Coax connector to 50 ohm antennna system.
9. 13.8V DC connection (via power supply) for meter LED illumination.
10. HF, VHF/UHF band switch : available on RS-502 only
11& 12. 2nd pair of TX/ANT connector : available on RS-502 only.
<FORWARD POWER MEASUREMENT>
1. Set the FUNCTION switch to FWD
<INSTALLATION> 2. Set the radio transceiver to transmit mode and read the scale
corresponding to the Power Range selected.
Transmitter SWR Meter 3. When the AVG/PEP button is 'out', the meter reads average RF power
When the button is 'depressed', the meter reads Peak Envelope Power
for use with SSB and AM transmissions. In this mode, there will be a
slow rise and decay time.
<REVERSE POWER MEASUREMENT>
DC power supply This measure the reverse power on the coaxial cable between transceiver
and antenna. The rest the settings are the same as that of
<OPERATION> < FORWARD POWER MEASUREMENT>
Transmitter Forward
<VSWR MEASUREMENT>
1. Set the radio transceiver to transmit mode and Function Switch to SWR SET
2. Slowly turn the SWR SET control knob clockwise until meter pointer is
at meter full scale
3. Set Function Switch to "SWR" position whilst still transmitting, the
meter will indicate VSWR ratio. (Note : handheld and mobile have H/L
range, when using 'H' range, read the upper SWR dial. Using 'L' range,
SWR Meter read the lower SWR dial)
[CAUTION]
Transmitter Reverse 1.Since the meter movement is very sensitive, avoid excessive vibration or
mechanical shock to the meter
2. Watch the absolute maximum power could be applied to the meter by
different models you bought.
3.The meter must never be reverse connected. Always observe the correct
connections to transmitter and antenna as indicated on the rear sockets
4.Do not expose the meter to excessive temperatures, high humidity, or
strong magnetic fields
SWR Meter
Ver. 20220301
KBC import / export, Argonstraat 6, 6718 WT Ede, The Netherlands
www.k-po.com