Manual KDT.qxd 17/06/2004 13:47 Page 1
14
ENG
Dear client:
Congratulations on your choice. We are sure
that this modern, functional and practical
appliance, made with top quality materials,
will fully satisfy your needs.
Please read every section of this
INSTRUCTIONS MANUAL before using your
kitchen hood for the first time, to ensure
maximum performance from the appliance
and to avoid breakdowns, which may be
caused by incorrect use, as well as to allow
any minor problems to be solved.
Store this manual, as it will provide useful
information about your kitchen hood at all
times and will also help other people to use it.
• Please be aware of current local
regulations with reference to domestic
electrical fittings and gas eduction.
• Verify that the tension and frequency of the
network match those indicated on the label
located inside the kitchen hood.
• The appliance must be connected to the
network using a break switch with a
universal cut off and minimum contact
separation of 3 mm.
• Once the kitchen hood has been installed,
ensure that the mains cable to the network
is not in contact with any live metal edges.
• Avoid connecting the appliance to
conductors used as exits for fumes
produced by a non-electric energy source,
e.g.: boilers, chimneys, etc.
• If the extractor fan is going to be used
simultaneously with equipment powered by
a non-electric energy source, e.g.: gas
cookers, the room must have sufficient
ventilation.
• Excessive fat accumulation in the kitchen
hood and metal filters is a fire risk and may
also cause dripping, therefore the inside of
the kitchen hood and the metal filters must
be cleaned at least once a month.
• The lower part of the kitchen hood must be
fitted at least 50 cm. over electric hobs and
65 cm. over gas or mixed hobs. FOLLOW
THE HOBS´ MANUFACTURER'S
MINIMUM RECOMMENDATIONS.
• Never leave gas hobs lit if not covered by a
container. The fat accumulated in the filters
may drip or catch fire when the
temperature increases.
• Avoid cooking under the kitchen hood if the
metal filters are not fitted, e.g.: while they
are being cleaned in the dishwasher.
• You must not produce flames under the
kitchen hood.
• Disconnect the appliance before any
interior manipulation, e.g. during cleaning
or maintenance.
• We recommend the use of gloves and to
be extremely careful when cleaning the
kitchen hood's interior.
• Your kitchen hood is designed for domestic
use and only for extraction and purification
of fumes produced during food
preparation. It will be your responsibility if it
is used for other purposes, which may be
dangerous. The manufacturer cannot
accept responsibility for damage caused
by improper use of the appliance.
• For repairs please contact the nearest
KÜPPERSBUSCH Technical Assistance
Service, and always use genuine spare
parts. Repairs or modifications carried out
by unqualified personnel can cause
malfunctions or may damage the
appliance, putting your safety in danger.
Safety Instructions
Manual KDT.qxd 17/06/2004 13:47 Page 14
15
ENG
Index
Page
Description of the appliance 15
Instructions for use 15
Programming timer 15
Cleaning and maintenance 16
Problem solving 16
Sizes and specifications 17
Accessories supplied 18
Installation 18
Active charcoal filters 18
AAn electronic programmer device with
TOUCH CONTROL technology to
control speed, light, programming and
power indicators in use as well as filter
saturation.
BMetal filters.
CLamp with two bulbs - 20 W (G-4).
D, E Vertically adjustable tubecovers.
Switch on the extractor fan a few minutes
before you start to cook in order to ensure that
a steady air flow has been established before
fumes appear.
Allow the extractor fan to run for several
minutes after you have finished cooking
(between 3 to 5 minutes) in order to expel all
the grease from the outlet duct. This prevents
the return of grease, smoke and smells.
Proceed as follows:
1) Turn the kitchen hood on and choose the
required speed. Press "timer". Suction
indicators 1, 2 and 3 will start to flash.
2) Select the required time by pressing the
increase and decrease speed selectors.
There is a variation of 10 in 10 minutes.
(Min.= 10 min.; Max.= 30 min.)
3) Once the required time has been selected,
press "timer" again to memorise the
program. The speed indicator in use will
start to flash.
4) Intensive suction cannot be programmed
as it has a set length of 10 minutes.
Clean the filters when the saturation indicator lights
up. (See page 16, Filter cleaning section).
Once you have cleaned the filters, and with the
hood turned off, press the increase and decrease
speed buttons at the same time for 3 seconds and
the indicator will switch itself off.
Instructions for use
Description of the appliance
Programming timer
You may control the kitchen hood by
operating the controls as shown in the
diagram.
Minimum speed
Medium speed
Maximum speed
Extra fan
Filter saturation
indicators
Timer
Reduce speed
Increase speed
On-Off
Power indicator
Filter saturation indicators
Manual KDT.qxd 17/06/2004 13:47 Page 15
16
ENG
During cleaning and maintenance work,
make sure the safety instructions set out
on page 14 are complied with.
• If your kitchen hood is made from stainless
steel, use proprietary cleaners mentioned
in the product instructions.
• If your hood has aluminium finish, use
lukewarm water and a neutral soap.
• Never use metallic scourers, nor abrasive
or corrosive products.
• Dry the kitchen hood using a cloth that
does not produce fibres.
To remove the filters from their fittings, press
lightly on the locks and then pull them off.
The metal filters can be cleaned by soaking
them in hot water with neutral detergent until
the fat dissolves and then rinsing them under
the tap or using special anti-grease products.
They can also be washed in a dishwasher. In
this case, it is advisable to stack them
vertically to avoid food residues to stick to
them.
Cleaning in a dishwasher with aggressive
detergents or polish may damage the metallic
surface (blackening it), although this will not
affect its fat retention capacity.
Once clean, leave them to dry off and then fit
them onto the kitchen hood.
Fig. 2 (Page 19)
Proceed as follows:
• Remove the metal filters.
• Loosen the screws (B) to dismount the
cover top (A).
• Dismount the support (C) by loosening the
screws (D).
• Change the broken/burnt out lamp (E).
Maximum lamp power is 20 W (G-4).
• Mount the supports again (C) and (A).
• Fit the metal filters.
Cleaning and maintenance
_________________________________________________________
Problem solving
Proceed with the following checks before calling the Technical Service:
Problem Possible cause Solution
The extractor fan does not work. The mains cable is not connected to the
network.
There is no current in the network.
Connect mains cable to the network.
Provide current to the network.
The kitchen hood does not extract
sufficiently or vibrates.
Filters are saturated with fat.
Obstruction in the air exit conduct.
Change or clean the active charcoal and/or metal
filters, as the case may be.
Remove the obstruction.
The lamps do not light up. The lamps are blown.
The lamps are slack.
Change the lamps.
Tighten the lamps.
Cleaning the hood body
Cleaning the metal filters
Changing light bulbs
Manual KDT.qxd 17/06/2004 13:47 Page 16
17
ENG
Sizes and specifications
AC 220 - 240 V 50 Hz
Tec. Cod. ES11042072KPMDT
F .Nr**********
Made in Europe
Technical Code
Network Tension
(V)
Network
Frequency (Hz)
Lights / Motor Power
(W)
Motor
Volume
ES11042072KPMDT 220 - 240 50 2 x 20/ 250
800 m3/h
KÜPPERSBUSCH reserves the right to make changes and corrections to its products
as it deems necessary, without altering their basic characteristics.
Manual KDT.qxd 17/06/2004 13:47 Page 17
18
ENG
1 150/ 120 mm reduction.
2 Supports for tubecover.
2 Supports hall.
6 Wall plugs (Ø8 x 40).
6 Long bolts (Ø5 x 45).
4 Wall plugs (Ø6 x 30).
4 Long bolts (Ø4 x 30).
2 Washers (Ø6,4 x Ø18).
2 Washers (Ø6,4 x Ø12).
2 Screws (Ø3,9 x 13).
4 Screws M4 x 12.
2 Clips.
Fig. 1 (Page 19)
On installing the kitchen hood make sure
that the Safety Instructions set out on page
14 are complied with.
To obtain optimum performance, the external
duct must not be more than FOUR METRES
LONG, have no more than two 90° angles and
its diameter must be at least Ø120.
1) Trace and drill the points for fitting the wall
plugs onto the wall (P) (Ø8 x 40) and (J) (Ø6 x
30).
2) Attach the Supports (O) to the wall using the
long bolts (Q) (Ø5 x 45) and the support (H)
with the long bolts (I) (Ø4 x 30), as in figure 1.
3) Hang the kitchen hood onto the mounted
supports (O). Straighten the appliance by
tightening the long bolts (L) (M4 x 12).
4) Remove the metal filters. Loosen the screws
(X) to dismount the cover top (W). Trace the
location of the long bolts (S) (Ø5 x 45).
5) Take the kitchen hood off.
6) Drill into the wall and fit the wall plugs (R)
(Ø8 x 40).
7) Hang the kitchen hood; tighten the screws
(M) (M4 x 12) with the washers (A3) (Ø6,4 x
Ø12) and the long bolts (S) (Ø5 x 45) with the
washers (T) (Ø6,4 x Ø18).
8) Mount the cover top again (W). Fit the metal
filters.
9) Mount the tubecovers, attaching the lower
one to the support (H) as per the detail in figure
1. Lift the upper tubecover up to the desired
height and mark its shape on the wall. Remove
the tubecovers.
10) Fit the clips (F) to the support (C).
11) Centre the support (C) around the shape
marked; trace and drill the fixing points for the
wall plugs (E) (Ø6 x 30). Attach the support (C)
with the long bolts (D) (Ø4 x 30).
12) Fit the part (B) if the inner tube (not
supplied) is Ø120.
13) Attach the inner tube with a clamp (not
supplied) to (B) or on to the motor's air outlet
vent as the case may be.
14) Once the inner tube is fitted, fit the lower
tubecover around the extractor fan outlet and
attach the upper tubecover with the screws (G)
(Ø3,9 x 13).
When exterior gas extraction is not possible,
then the kitchen hood may be set to purify the
air by recycling it through active charcoal
filters.
The active charcoal filters have an active life of
between three to six months, depending on
the individual conditions of use. These filters
cannot be washed nor regenerated. They must
be replaced once their useful life comes to an
end.
Fig. 3 (Page 19)
1) Remove the metal filters. Loosen the screws
(J) to dismount the cover top (I).
2) Put the filters into the lateral draught section
of the motor making the holes in the filters
match up (A) with the pivots (B) of the motor
carcass. Turn as indicated in the diagram.
3) Mount the support again (I). Fit the metal
filters.
4) Remove the tubecovers (E). Use the wall
plugs and the previously installed upper
tubecover's support (G) long bolts (D) to fix
diffuser (C) into the wall.
5) Connect the diffuser base (C) to the motor
exit via the inner tube (not supplied). Use
clamps (Not supplied). Fit the tubecovers (E)
again.
Active charcoal filters (Optional)
Installation
Accesories supplied
Manual KDT.qxd 17/06/2004 13:47 Page 18
19
ENG
333
MIN 500
MIN 650
77
38 38
FIG. 1
FIG. 2 FIG. 3
Manual KDT.qxd 17/06/2004 13:48 Page 19

Other Küppersbusch Ventilation Hood manuals

Küppersbusch DX ISLA User manual

Küppersbusch

Küppersbusch DX ISLA User manual

Küppersbusch EM6-EM10 Quick setup guide

Küppersbusch

Küppersbusch EM6-EM10 Quick setup guide

Küppersbusch IKD9350.0 Quick setup guide

Küppersbusch

Küppersbusch IKD9350.0 Quick setup guide

Küppersbusch EDD9960.OGE Technical manual

Küppersbusch

Küppersbusch EDD9960.OGE Technical manual

Küppersbusch IKD3700.0 Quick setup guide

Küppersbusch

Küppersbusch IKD3700.0 Quick setup guide

Küppersbusch HI981420 Operation manual

Küppersbusch

Küppersbusch HI981420 Operation manual

Küppersbusch CSW6870 0 Series Operation manual

Küppersbusch

Küppersbusch CSW6870 0 Series Operation manual

Küppersbusch Hood User manual

Küppersbusch

Küppersbusch Hood User manual

Küppersbusch 55 cm User manual

Küppersbusch

Küppersbusch 55 cm User manual

Küppersbusch KD 9200.2 E Operation manual

Küppersbusch

Küppersbusch KD 9200.2 E Operation manual

Küppersbusch KD 646.1 E Operation manual

Küppersbusch

Küppersbusch KD 646.1 E Operation manual

Küppersbusch EDIP 633... Quick setup guide

Küppersbusch

Küppersbusch EDIP 633... Quick setup guide

Küppersbusch EDIP 644.0 Quick setup guide

Küppersbusch

Küppersbusch EDIP 644.0 Quick setup guide

Küppersbusch LB6700.0E Quick setup guide

Küppersbusch

Küppersbusch LB6700.0E Quick setup guide

Küppersbusch Hood User manual

Küppersbusch

Küppersbusch Hood User manual

Küppersbusch KD 8950.0 Technical manual

Küppersbusch

Küppersbusch KD 8950.0 Technical manual

Küppersbusch IKD 9420.0 GE-CN Operation manual

Küppersbusch

Küppersbusch IKD 9420.0 GE-CN Operation manual

Küppersbusch EDIP 6400.1 E Quick setup guide

Küppersbusch

Küppersbusch EDIP 6400.1 E Quick setup guide

Küppersbusch IKD 908.1 Quick setup guide

Küppersbusch

Küppersbusch IKD 908.1 Quick setup guide

Küppersbusch EKD 10650.0E-84 User manual

Küppersbusch

Küppersbusch EKD 10650.0E-84 User manual

Küppersbusch KD 9570.2 J Operation manual

Küppersbusch

Küppersbusch KD 9570.2 J Operation manual

Küppersbusch KD 9420.0 GE-CN Operation manual

Küppersbusch

Küppersbusch KD 9420.0 GE-CN Operation manual

Küppersbusch D633.1 Quick setup guide

Küppersbusch

Küppersbusch D633.1 Quick setup guide

Küppersbusch EMA1008.0E User manual

Küppersbusch

Küppersbusch EMA1008.0E User manual

Popular Ventilation Hood manuals by other brands

Broan Best IS170 specification

Broan

Broan Best IS170 specification

Zephyr Essentials ZAN-E30CBS Use, care and installation guide

Zephyr Essentials

Zephyr Essentials ZAN-E30CBS Use, care and installation guide

Pelgrim OWA305 Series Instructions for use

Pelgrim

Pelgrim OWA305 Series Instructions for use

ELICA Mini Om Instruction on mounting and use

ELICA

ELICA Mini Om Instruction on mounting and use

Remus 0105 088115 Installation instruction

Remus

Remus 0105 088115 Installation instruction

Electrolux EFC216V user manual

Electrolux

Electrolux EFC216V user manual

Refsta OPERA Installation, operating and maintenance instructions

Refsta

Refsta OPERA Installation, operating and maintenance instructions

Bompani bocr904 instruction manual

Bompani

Bompani bocr904 instruction manual

Zline 432-30 Installation guide and user's manual

Zline

Zline 432-30 Installation guide and user's manual

Lapetek LUNA-X Service, installation and care manual

Lapetek

Lapetek LUNA-X Service, installation and care manual

Miele DA 7000 D Operating and installation instructions

Miele

Miele DA 7000 D Operating and installation instructions

Novy Salsa 6500 installation instructions

Novy

Novy Salsa 6500 installation instructions

Pkm KH-60KHSX instruction manual

Pkm

Pkm KH-60KHSX instruction manual

Beko CWB 9700 X user manual

Beko

Beko CWB 9700 X user manual

LE MARQUIER 60 ORIGINAL ADELA V2 instructions

LE MARQUIER

LE MARQUIER 60 ORIGINAL ADELA V2 instructions

Smeg SHR900X user manual

Smeg

Smeg SHR900X user manual

Venduro TA 60-100 manual

Venduro

Venduro TA 60-100 manual

NuTone NW830SS Installation use and care manual

NuTone

NuTone NW830SS Installation use and care manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.