Kaden KD Series User manual

Kaden Wired Controller Manual | 1
Wired
Controller
Manual
DUCTED AIR CONDITIONER
KD24 | KD36 | KD42 | KD48 | KD60
KD Series

2| Kaden Wired Controller Manual
1. Safety Precautions 3
2. Installation Accessories 4
3. Installation Method 5
4. Specification 8
5. Features and Functions 9
6. Display Screen 10
7. Buttons 11
8. Operation 12
9. Timer Functions 14
10. Weekly Timer 15
11. Fault Alarms 18
Important note:
Read this manual carefully before installing
or operating your new air conditioning unit.
This manual gives detailed description of the
precautions that should be followed during operation.
Make sure to save this manual for future reference.
Table of Contents

Kaden Wired Controller Manual | 3
Read Safety Precautions Before Installation
Read the safety precautions carefully before installing the unit. Stated below are important safety issues that must
be obeyed:
1. Safety Precautions
Means improper handling may lead to personal death or severe injury.
Means improper handling may lead to personal injury or property loss.
WARNING
• Please ensure a professional installs the unit.
• Installation by other persons may lead to incorrect installation, electric shock or fire. Adhere to this installation manual.
CAUTION
• Do not install the unit in a place vulnerable to leakage of flammable gases. Leaking flammable gases around the
controller can result in fire.
• Do not operate with wet hands or let water enter the wired controller. Otherwise, electric shock may occur.
• The wiring should adapt to the wired controller current. Otherwise, electric leakage or over heating may occur and
result in fire.
• The specified cables shall be used in the wiring. No external force should be applied to the terminal.
This may result in damaged wiring and/or overheating which can create a fire hazard.

4| Kaden Wired Controller Manual
2. Installation Accessories
Select the installation location
Don’t install in areas that contain oil, vapor or sulfureted gas, otherwise, this product can deform which could permanently damage
the product.
1. Please confirm that you have all the following parts.
No. Name Qty. Remarks
1 Wired controller 1
2Wired controller manual 1
Kaden Wired Controller Manual | 1
Wired
Controller
Manual
DUCTED AIR CONDITIONER
KD24 | KD36 | KD42 | KD48 | KD60
KD Series
3 Screws 3 M4X20 (for mounting on the wall)
4Wall plugs 3 For mounting on the wall
5 Screws 2 M4X25 (for mounting on switch box)
6Plastic screw bars 2 For fixing on switch box
7 The connective wires group-1 1 Optional
8 The connective wires group-2 1 Connect to mainboard
9 Battery 1
2. Prepare the following assemblies on the site.
No. Name Qty. (embedded into wall)
1 Switch box 1
2Wiring tube (insulating sleeve and tightening screw) 1
Preparation before installation
1. This manual explains the installation requirements for the wired controller. Please refer to the wiring diagram of this installation
manual to wire the wired controller to the indoor unit.
2. The wired controller operates in a low voltage loop circuit. Do not directly contact the cable of 220V commercial electricity or
of 380V high voltage, and don’t wire this kind of wire in the loop; wiring clearance between configured tubes should be at the
range of 300~500 or above.
3. The shielded wire of the wired controller must be grounded reliably.
4. Upon completing the wired controller connection, do not use a mega to detect the insulation.
5. The connective cable of the wired controller should not be longer than 20 meters.
Precautions

Kaden Wired Controller Manual | 5
3. Installation Method
120
122
18.5
83.5
46
62
1. Wired controller size
2. Wiring principle sketch
red
black
yellow
brown
red
black
yellow
brown
Insert of the
mainboard CN40
Wired controller Indoor unit mainboard
4-Core Shield Cable,
the length is dictated by installation
-----------------------------------
-----------------------------------
-----------------------------------
-----------------------------------
3. Wiring figure
Mainboard
4-core shielding wire
The connective wires group-1
The connective wires group-2
CN40
• Connect the female joint of wires group from the mainboard with the male joint of connective wires group.
• Please connect the other side of connective wires group with the male joint of wires group leads from the wired controller.

6| Kaden Wired Controller Manual
4. Remove the upper part
of the wired controller
Insert a slotted screwdriver into the slots in the lower part of the
wired controller (2 places), and remove the upper part of the
wired controller.
NOTICE
The PCB is mounted in the upper part of the wired
controller. Be careful not to damage the board with
the slotted screwdriver.
Slots
5. Fasten the back plate of the wired controller
For exposed mounting, fasten the back plate on the
wall with the 3 screws (M4×20) and plugs.
For flush-mounting, fasten the back plate on the switch
box with 2 screws (M4×25) and fasten it on the wall with
1 screw (M4×20).
NOTICE
Put on a flat surface. Be careful not to distort the back plate of the wired controller by overtightening the mounting screws.
Back plate
Screws (M4×20)
Switch box
Back plate
Screw (M4×20)
Screws (M4×25)
6. Battery installation
• Put the battery into the installation site and make sure the
positive side of the battery is in accordance with the positive
side of installation site. (See figure opposite.)
• Please set the time during first operation. Batteries in the
wired controller can fail during a power failure. When power
is restored, if the time displayed is not correct, it means the
battery is dead and requires replacing.

Kaden Wired Controller Manual | 7
7. Wiring
A. In regards to wiring outlets,
there are four options.
Three need cutting.
CAUTION
• Avoid water ingress into the wired controller, use trap
and putty to seal the connectors of wires during wiring
installation.
• During installation, leave some length of the connecting
wires for convenient maintenance, when the controller
needs to be removed from its location.
Top side
wire outlet
Left side
wire outlet
Right side
wire outlet
Bottom side
wire outlet
Line groove
Line groove
Line groove
Line groove
Cutting place
of top side
wire outlet
Cutting place
of left side
wire outlet
Cutting place
of right side
wire outlet
B. Shielded wiring
diameter of wall hole
:
Φ20mm
Embedded switch
box wiring
Wiring
hole
Wiring through the wall
Wall hole and wiring hole
Putty
Putty
Putty
Trap
Trap
Trap

8| Kaden Wired Controller Manual
8. Reattach the upper part of the
wired controller
After adjusting the upper case click it into place; avoid clamping
the wiring during this process.
Note
All the pictures in this manual are for explanation
purpose only.
Your wired controller may be slightly different.
In this case the actual shape shall prevail.
4. Specification
Input voltage Ambient temperature Ambient humidity
DC 5V/DC 12V -5~43ºC RH40%~RH90%

Kaden Wired Controller Manual | 9
5. Features and Functions
POWER
MODE FAN SPEED
TIMER SWING SWING FOLLOW ME
DELAY/DAY OFF CONFIRM BACK COPY
Features
• Mode: Auto – Cool – Dry – Heat – Fan
• Fan speed: Auto/Low/Med/High
• Timer ON/OFF
• Temp setting
• Weekly timer
• Follow me
• Child lock
• LCD display
• Clock
• Infrared remote receiver (on some models)
Function
• LCD display.
• Malfunction code display: Displays error codes.
• 4-way wire layout design, no raised part at back, more
convenient to place the wires and install the device.
• Room temperature display.
• Weekly Timer.

10 | Kaden Wired Controller Manual
6. Display Screen
1 2 3 4 5
6
7
8
9
10
12 11
1. Operation mode
2. Fan speed
3. Faceplate function
4. Follow me function
5. Turbo mode
6. ºC / ºF
7. Temperature display
8. Lock
9. Room temperature
10. Clock display
11. On/Off timer
12. Timer display

Kaden Wired Controller Manual | 11
7. Buttons
1
2
3
4
5
6
7
89
10
POWER
MODE FAN SPEED
TIMER SWING SWING FOLLOW ME
DELAY/DAY OFF CONFIRM BACK COPY
11
1. POWER
2. MODE
3. Adjust
4. FAN SPEED
5. FOLLOW ME/TURBO MODE
6. TIMER
7. DELAY/DAY OFF
8. CONFIRM
9. BACK
10. COPY
11. Infrared remote receiver (on some models)

12 | Kaden Wired Controller Manual
8. Operation
Set the current day and time
Remote signal receiving function
The wired controller can be a remote signal receiving device,
you can use the wireless remote controller to control the
air-conditioner through the wired remote controller when the
system has been powered on.
1. Press the TIMER button for 3 seconds or more.
The timer display will flash.
TIMER
3. The day setting is finished and the time setting is ready
to set after pressing TIMER button or if you don’t press a
button in 10 seconds.
TIMER
5. The setting is done after pressing TIMER button
or if you don’t press a button in 10 seconds.
TIMER
2. Press the button “+” or “–” to set the day.
The selected day will flash.
4. Press the button “+” or “–” to set the current time.
Press repeatedly to adjust the current time in 1-minute
increments. Press and hold to adjust the current
time quickly.
ex.Monday AM 11:20
To start/stop operation
Press the POWER button.
Operation lamp
Air conditioner ON: Lit brightly
Air conditioner OFF: Not lit
POWER
To set the operation mode
Mode setting
Press the MODE button to set the mode.
MODE
Room temperature
Press the button “+”or “–” to set the room temperature.
Indoor Setting Temperature Range: 17~30ºC
Lower Higher
Fan speed setting
Press the FAN SPEED button to set the fan speed. (This button
does not work when in Auto or Dry mode.)
FAN
SPEED

Kaden Wired Controller Manual | 13
Room temperature sensor selection
Press the FOLLOW ME button to select whether the room
temperature is detected at the indoor unit or the wired controller.
When the Follow Me function indicator appears ,
the room temperature is detected at the wired controller.
FOLLOW
ME
Indoor Unit
Turbo Mode
Press and hold the FOLLOW ME button for 5 or more seconds.
The unit will enter TURBO MODE. Please note that TURBO
MODE does not work in heating mode.
When TURBO MODE is activated the icon mark appears.
FOLLOW
ME
TURBO
Child lock function
Press the button “+” and “–” simultaneously for 3 seconds
to activate the child lock function and lock all buttons on
the wired controller. Press the buttons again for 3 seconds
to deactivate the child lock function.
When the child lock function is activated, the icon
mark appears.
Keypad tone setting
Press the button “BACK” and “COPY” simultaneously for 3
seconds to close the keypad tone.
Press the buttons again for 3 seconds to open the keypad tone.
BACK COPY
Press and hold and buttons together for 3 seconds,
this will alternate the temperature display between ºC and ºF.
°C & °F scale selection
(on some models)
SWING SWING
Left-Right swing
Pressing the button will not do anything. This button is
irrelevant for your air-conditioner.
SWINGSWING
Up-Down airflow direction
and swing
Pressing the button will not do anything. This button is
irrelevant for your air-conditioner.
SWING SWING

14 | Kaden Wired Controller Manual
9. Timer Functions
WEEKLY timer
Use this timer function to set operating times for
each day of the week.
On timer
Use this timer function to start air conditioner
operation. The timer operates and air conditioner
operation starts after the time has passed.
Off timer
Use this timer function to stop air conditioner
operation.The timer operates and air conditioner
operation stops after the time has passed.
On and Off timer
Use this timer function to start and stop air
conditioner operation.The timer operates and air
conditioner operation starts and stops after the
time has passed.
To set the On or Off TIMER
To set the On and Off TIMER
1. Press the TIMER button to select the or .
2. Press the CONFIRM button and the Clock display
will flash.
3. Press the button “+” or “–” to set the time. After the time
is set, the timer will start or stop automatically.
4. Press the CONFIRM button again to finish.
No display
TIMER
1. Press the TIMER button to select the button.
TIMER
CONFIRM
2. Press the CONFIRM button and the Clock display
will flash.
CONFIRM
5. Press the CONFIRM button to finish.
CONFIRM
CONFIRM
3. Press the button “+” or “–” to set the time of On timer,
and then press the CONFIRM button to confirm.
CONFIRM
4. Press the button “+” or “–” to set the time of Off timer.
ex.Off timer set at 6:00PM

Kaden Wired Controller Manual | 15
10. Weekly Timer
TIMER
CONFIRM
Press the TIMER button to select the button and then
press the CONFIRM button to confirm.
1. Weekly timer setting
Press the button “+” or “–” to select the day of the week and
then press the CONFIRM button to confirm the setting.
CONFIRM
2. Day of the week setting
Press the button “+” or “–” to set the time of On timer and
then press the CONFIRM button to confirm the setting.
CONFIRM
ex.Tuesday time scale 1
Up to 4 timer settings can
be saved for each day of
the week.It is convenient if
the WEEKLY TIMER is set
according to the user’s life style.
3. ON timer setting of timer setting 1
Press the button “+” or “–” to set the time of Off timer and then
press the Confirm button to confirm the setting.
CONFIRM
4. Off timer setting of timer setting 1
5. Different timer settings can be set
by repeating steps 3 to 4.
6. Other days in one week can be
set by repeating steps 2 to 5.
Note
• In the weekly timer setting you can return to the previous
step by pressing the BACK button.
• The time of the timer setting can be deleted by pressing
the DAY OFF botton
• The current setting will be restored and withdrawn
automatically when there is no operation for 30 seconds.

16 | Kaden Wired Controller Manual
WEEKLY timer operation
To deactivate WEEKLY TIMER function
Press the TIMER button while disappears from the
LCD screen.
To activate WEEKLY TIMER function
Press the TIMER button while is displayed on the
LCD screen.
TIMER
To turn off the air conditioner during the weekly timer
1. If you press the POWER button once and quickly, the air
conditioner will turn off temporarily. And the air conditioner
will turn on automatically until the time of On timer.
Example: If you press the POWER button once and quickly
at 10:00, the air conditioner will turn on at 14:00.
2. When you press the POWER button for 2 seconds, the air
conditioner will turn off completely.
ON OFF ON OFF
8:00 12:00 14:00 17:0010:00
To set the DAY OFF (for a holiday)
4. The DAY OFF can be set for other days by repeating
steps 2 and 3.
1. During the weekly timer, press the CONFIRM button.
CONFIRM
2. Press the button “+” or “–” to select the day in the week.
Note
• To cancel: Follow the same procedures as those for
setup.
• The DAY OFF setting is cancelled automatically after the
set day has passed.
3. Press the DAY OFF button to set the DAY OFF.
DELAY/DAY OFF
ex.The DAY OFF is set for Wednesday
The mark is hidden
5. Press the BACK button to go back to the weekly timer.
BACK

Kaden Wired Controller Manual | 17
DELAY function Copy the setting from one day
to another day.
During the weekly timer, pressing the DELAY button once,
displays .
Pressing this button twice, displays and wait 3 seconds
to confirm. It means the unit will override 1 hours.
Pressing this button three times, displays and wait
3 seconds to confirm. It means the unit will override 2 hours.
DELAY/DAY OFF
Example: If you press the DELAY button to select at 18:05,
the air conditioner will delay to turn off to 20:05.
A timer made once can be copied to another day of the week.
The setting of the selected day of the week will be copied.
The effective use of the copy mode ensures ease of making
other timer settings.
1. During weekly timer, press the CONFIRM button.
2. Press the button “+” or “–” to select the day to copy from.
3. Press the COPY button, the letters “CY” will be shown on
the LCD screen.
4. Press the button “+” or “–” to select the day to copy to.
5. Press the COPY button to confirm.
6. Other days can be copied by repeating steps 4 and 5.
7. Press the Confirm button to confirm the settings.
8. Press the Back button to go back to the weekly timer.
CONFIRM
COPY
COPY
Example: Copied the setting
of Monday to Wednesday
The mark flashes quickly
CONFIRM
BACK

18 | Kaden Wired Controller Manual
11. Fault Alarms
If the system does not properly operate, investigate according to the following procedures.
No. Malfunction & Protection Define Display Digital Tube
1 Error of communication between wired controller and indoor unit F0
2 The faceplate is abnormal F1
Please check the error display of the indoor unit and read the unit owners manual if other error codes appear.

Kaden Wired Controller Manual | 19
Notes

20 | Kaden Wired Controller Manual
kadenair.com.au
Other manuals for KD Series
3
This manual suits for next models
5
Table of contents
Other Kaden Controllers manuals