Kallista P19300 Assembly instructions

Installation and Care Guide
Single-Handle Bath and Shower Valves
Français, page “Français-1”
Español, página “Español-1”
P19300
089585-2-BE

IMPORTANT INSTRUCTIONS
READ AND SAVE FOR THE
CONSUMER
WARNING: Risk of scalding or other severe injury.
•Before completing installation, the installer must set the
maximum water temperature setting of this valve to minimize the
risks associated with scalding hazards according to ASTM F 444.
•Do not install a shut-off device on either outlet of this valve. The
installation of any such device may create a cross-flow condition
at the valve and affect the water temperature.
•Factors that change the temperature of the water supplied to the
valve, such as seasonal water temperature changes, and water
heater replacement or servicing, will change the maximum water
temperature supplied by the valve and may create a scalding
hazard. The pressure-balanced valve will not compensate for
changes in the water supply temperature; adjust the maximum
water temperature setting of this pressure-balanced valve when
such changes occur.
•Pressure-balanced valves may not provide protection against
scalding if there is a failure of other temperature-limiting devices
elsewhere in the plumbing system.
NOTICE: Only apply silicone-based lubricants to these valves. Do
not use petroleum-based lubricants. Petroleum-based lubricants will
harm the O-rings, seals, and plastic components.
The installer is responsible for installing the valve and adjusting the
maximum water temperature of this pressure-balanced valve
according to instructions.
This valve meets or exceeds ANSI A112.18.1 and ASSE 1016.
If you do not understand any of the installation or temperature
adjustment instructions in this document, in the United States please
contact our Customer Care Center at 1-888-4-KALLISTA.
PEX connections are designed for use with any ASTM F 1807
compliant copper crimp rings and ASTM F 887 compliant PEX tubing.
These fittings are not compatible with ASTM F 1960 cold expansion
fittings with PEX reinforcing ring assemblies.
089585-2-BE 2 Kallista

IMPORTANT INSTRUCTIONS (cont.)
The PEX fittings on this valve have been third party certified by CSA using the following: Sioux Chief 1/2” copper
crimp ring and CSA certified VANGUARD VANEX®1/2” PEX potable tubing. Crimps were made using a Sioux Chief
1/2” crimp tool in accordance with the Sioux Chief instructions.
PEX connections are designed for use with any ASTM F 1960
compliant cold expansion retaining rings and ASTM F 887 compliant
PEX tubing. These fittings are not compatible with ASTM F 1807
copper crimp reinforcing ring and PEX tubing assemblies.
The PEX fittings on this valve have been third party certified by CSA using the following: WIRSBO AQUAPEX 1/2”
potable tubing, Uponor ProPEX 1/2” cold expansion retaining rings and the Uponor ProPEX Hand Expander tool in
accordance with the Uponor Instructions.
IMPORTANT NOTICE TO INSTALLERS! Please fill in the blanks in
the information box below. Retain this Guide for future reference.
NOTICE TO HOMEOWNERS! This device has been preset by
_______________________ of _______________________________ to
ensure a safe maximum temperature. Any change in the setting may
raise the discharge temperature above the limit considered safe, and
lead to scalds.
Date: ______________
Tools and Materials
Before You Begin
CAUTION: Risk of personal injury. The water temperature
should never be set above 120°F (49°C).
Strap Wrench
Sealant Tape
SolderPEX Crimp Tool
(Optional)
Hex Wrench
Hacksaw or
Tubing Cutter
Cold
Expansion Tool
Kallista 3 089585-2-BE

Before You Begin (cont.)
NOTICE: Use only 1/2″(5/8″OD) copper pipe (type L or M)
between the valve and bath spout. Using other materials may cause
back pressure and result in water flowing from the showerhead and
bath spout at the same time.
NOTICE: Some installations require valve trim roughing-in
dimensions different from those shown in this guide. Refer to the
valve trim specification sheet to confirm dimensions.
NOTICE: Do not force the handle in any direction. Forcing the
handle will damage the valve.
Observe all local plumbing and building codes.
Shut off the main water supply.
Kallista reserves the right to make revisions in the design of
faucets without notice, as specified in the Price Book.
089585-2-BE 4 Kallista

Roughing-In
Thin Wall
2-3/4" (70 mm)
Thick Wall
2-3/4" (70 mm) –
3-1/2" (89 mm)
2-1/16"
(52 mm)
2-1/16"
(52 mm)
2x4
Bracing
4" (102 mm)
7" (178 mm) –
18" (457 mm)
[10" (254 mm)
Recommended]
72" (1829 mm) –
78" (1981 mm)
To Floor (Typical)
48" (1220 mm)
To Floor
Shower Only
Bath/Shower
2x4
Bracing
Kallista 5 089585-2-BE

1. Prepare the Valve
IMPORTANT! The internal components of the valve will only need
to be removed for back-to-back installations (reversed valve only) or
installations that require soldering of connections.
NOTE: Only valves with stops will include the stop assembly.
Installations Requiring Soldering
Remove the plaster guard (not shown).
Remove internal valve components as shown and set aside.
Back-to-Back Installations
Remove the plaster guard (not shown).
For the reversed valve, remove internal components as shown
and set aside. The stop assembly does not need to be removed if
soldering is not needed.
Stop
Assembly
089585-2-BE 6 Kallista

2. Position the Valve and Route Piping
Install Support Framing
NOTE: The position of the 2x4 bracing is dependent on the
thickness of your finished wall. Refer to the ″Roughing-In″Section.
Determine the valve location and install 2x4 bracing behind the
valve plate.
Install bracing at the showerhead and bath spout installation
locations.
Route Piping and Connect the Supplies
IMPORTANT! Do not use multiple elbows on the bath spout outlet.
Use 1/2″NPT threaded adapters or solder 1/2″copper directly to
the outlet.
Install 1/2″piping and elbows to the showerhead and bath spout
outlets. Use sealant tape on all threaded connections.
Secure the piping to the framing.
Connect the water supplies using 1/2” copper, CPVC, or PEX
components.
Hot Supply Cold Supply
1/2" Pipe
Nipple
Cap
Sealant
Tape
2x4
Bracing
Kallista 7 089585-2-BE

Position the Valve and Route Piping (cont.)
Solder all needed connections.
Temporarily install 1/2” pipe nipples to the elbows so they will
extend at least 2” (51 mm) beyond the finished wall.
Install caps to both pipe nipples.
089585-2-BE 8 Kallista

3. Back-To-Back Installation
NOTICE: Do not install the valve body upside down.
Route the supplies and install the valves. Refer to the roughing-in
illustration for your installation.
NOTE: One valve will have reversed supply connections, hot
supply to ″COLD″inlet and cold supply to ″HOT″inlet.
Connect the water supplies as shown. Use sealant tape on all
threaded connections.
Install 2x4 bracing behind the plate (not shown).
Cold Supply
Hot Supply
Reversed
Valve
Kallista 9 089585-2-BE

4. Reassemble the Valve
Slowly open the main water supply and flush the system before
assembling the internal components.
Turn off the water supply.
Reinstall the stop assembly (if present) and the pressure balancing
unit.
Reinstall the cap assembly with the tab oriented up.
For reversed valves in back-to-back installations: reinstall the
cap assembly with the tab oriented down.
Install the collar and secure with the screws.
Stop
Assembly Tab Up
Reversed Valve Only
Tab Down
089585-2-BE 10 Kallista

5. Flush the System
Remove the cap from one of the pipe nipples.
Turn the valve stem clockwise to the full open position.
Turn on the hot and cold water supplies. Check for leaks.
Turn the valve stem counterclockwise to close.
Reinstall the cap.
Repeat for the second pipe nipple.
Reinstall the cap.
Cap
Valve Stem
Kallista 11 089585-2-BE

6. Install the Finished Wall
Thick Wall
NOTE: The plaster guard can be used as a guide for marking the
cutout.
Cut a 5-9/16″(141 mm) hole in the wall material.
Install the finished wall material.
Leave the plaster guard in place at this time.
Finished
Wall
Ø 5-9/16"
(141 mm)
Ø 5-9/16"
(141 mm)
2-3/4" (70 mm) –
3-1/2" (89 mm)
089585-2-BE 12 Kallista

7. Install the Finished Wall
Thin Wall
Twist the dome of the plaster guard to separate it from the outer
ring. Discard the outer ring.
Slide the dome over the valve stem.
NOTE: The plaster guard dome can be used as a guide for marking
the cutout.
Cuta4″(102 mm) hole in the wall material.
For Valves with Stops: Using the holes in the valve backing plate
as a guide, cut openings for the stops.
Secure the wall material to the valve backing plate at the
locations shown.
Leave the plaster guard dome in place at this time.
2-3/4" (70 mm)
Wall
Material
Discard.
45˚
1-9/16" (40 mm)
1-9/16"
(40 mm)
Ø 4-1/2"
(114 mm)
Drywall
Screws
Ø 4"
(102 mm)
Kallista 13 089585-2-BE

Temperature Limiting Adjustment
CAUTION: Risk of personal injury. The water temperature
should never be set above 120°F (49°C).
Turn the valve stem clockwise to the full open position. Allow the
water to run for several minutes.
Using a thermometer, check the water temperature.
Turn off the water.
Minor Temperature Adjustment
Using a hex wrench, turn the setscrew clockwise to lower the
temperature and counterclockwise to raise the temperature.
Recheck the water temperature.
Major Temperature Adjustment
Remove the O-ring and collar from the valve stem.
Slowly turn the valve stem until the water temperature is 120°F
(49°C) or less.
Leave the water running at the desired maximum temperature
and reinstall the collar with the setscrew positioned against the
tab.
Turn off the water.
Reinstall the O-ring.
Collar
O-Ring
Setscrew
Minor Adjustment
Valve Stem Major Adjustment
Tab
089585-2-BE 14 Kallista

Warranty
FIVE-YEAR LIMITED WARRANTY
All Kallista products carry Kallista’s five-year limited warranty unless
otherwise noted.*
Kallista products are warranted to be free of defects in material and
workmanship for five years from the date of installation.
Kallista will, at its election, repair, replace, or make appropriate
adjustment where Kallista inspection discloses any such defects
occurring in normal usage within five (5) years after installation.
Kallista is not responsible for removal or installation costs. Damages
due to improper handling, installation or maintenance are not
considered manufacturing defects and are not covered by this
warranty. This warranty is valid for the original consumer purchaser
only. Use of in-tank toilet cleaners will void the warranty.
To obtain warranty service, contact your Kallista Authorized
Showroom.
IMPLIED WARRANTIES INCLUDING THAT OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE ARE EXPRESSLY LIMITED IN DURATION TO THE
DURATION OF THIS WARRANTY. KALLISTA AND/OR SELLER
DISCLAIMS ANY LIABILITY FOR SPECIAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES.
Some states/provinces do not allow limitations on how long an
implied warranty lasts, or the exclusion or limitation of special,
incidental or consequential damages, so these limitations and
exclusions may not apply to you. This warranty gives you specific
legal rights. You may also have other rights which vary from
state/province to state/province.
This is Kallista’s exclusive written warranty.
* Kallista’s Hampstead and Stafford vitreous products, stainless steel
accessories, and wooden accessories carry a one-year Limited Warranty.
Kallista 15 089585-2-BE

Service Parts
77759
Cap
Pressure
Balancing Unit
O-Ring
O-Ring
O-Ring
O-Ring Collar Screw
Plate
A
21980
79478
1095944
77585
29296
500520
42043
Collar
75740
73933
**Finish/color code must be specified when ordering.
Cap
71933
A
A
P19300-WS-NA
Cap
Stop
1083638
71933
P19300-00-NA
P19300-BB-NA
O-Ring
1086745
P19300-US-NA
Cap
71933
Stop
77148
A
089585-2-BE 16 Kallista

Guide d’installation et d’entretien
Baignoire à une poignée et vannes de douche
INSTRUCTIONS IMPORTANTES
LIRE ET CONVERSER POUR LE
CONSOMMATEUR
AVERTISSEMENT: Risque de brûlures ou d’autres
blessures graves.
•Avant de commencer l’installation, l’installateur doit régler la
température maximale de l’eau de ce régulateur afin de réduire
au minimum les risques associés aux dangers de brûlures selon la
norme ASTM F 444.
•Ne pas installer de dispositif d’arrêt sur les sorties de ce
régulateur. L’installation d’un tel dispositif peut créer une
condition de débit croisé au niveau du robinet et peut modifier la
température de l’eau.
•Les facteurs qui changent la température de l’eau fournie à ce
robinet, tels que les changements de température d’eau
saisonniers, et le remplacement ou l’entretien du chauffe-eau,
changeront la température maximale de l’eau fournie par la
vanne et pourront présenter un danger de brûlures. Le robinet à
pression autorégularisée ne compense pas les changements de
température de l’eau fournie; lorsque de tels changements ont
lieu, régulariser la température maximale de l’eau de ce robinet à
pression autorégularisée.
•Les robinets à pression autorégularisée peuvent ne pas assurer
une protection contre les brûlures en cas de défaillance d’autres
dispositifs de limitation de température installés ailleurs sur le
réseau de plomberie.
AVIS: Seuls des lubrifiants à base de silicone peuvent être appliqués
sur ces vannes. Ne pas utiliser de lubrifiants à base de pétrole. Des
lubrifiants à base de pétrole endommageront les joints toriques, les
joints et les composants en plastique.
Kallista Français-1 089585-2-BE

INSTRUCTIONS IMPORTANTES (cont.)
L’installateur est responsable de l’installation du robinet et du
réglage de la température maximale de l’eau de ce robinet à pression
autorégularisée conformément aux instructions.
Ce robinet répond aux exigences des normes ANSI A112.18.1 et ASSE
1016 ou les dépasse.
Si les instructions d’installation ou de réglage de la température
fournies dans le présent document ne sont pas bien comprises,
contacter notre centre de service clientèle aux États-Unis à
1-888-4-KALLISTA.
Les raccords PEX sont conçus pour être utilisés avec les bagues de
compression en cuivre conformes à la norme ASTM F 1807 et toute
tuyauterie PEX conforme à la norme ASTM F 887. Ces raccords ne sont
pas compatibles avec les raccords d’expansion ASTM F 1960 avec
ensembles de bagues de renforcement PEX.
Les raccords PEX de cette vanne on été certifiés par une tierce partie, par la CSA, en utilisant ce qui suit: Bague de
compression Sioux Chief 1/2” en cuivre et tuyauterie potable VANGUARD VANEX®1/2” PEX certifiée CSA. Les
compressions ont été fabriquées en utilisant un outil de sertissage Sioux Chief 1/2” conformément aux instructions de
Sioux Chief.
Les raccords PEX sont conçus pour être utilisés avec les bagues de
retenue à expansion à froid conformes à la norme ASTM F 1960 et à la
tuyauterie PEX conforme à la norme ASTM F 887. Ces raccords ne sont
pas compatibles avec la bague de renforcement de sertissage ASTM F
1807 en cuivre ou les ensembles de tuyauterie PEX.
Les raccords PEX de cette vanne on été certifiés par une tierce partie, par la CSA, en utilisant ce qui suit: Tuyauterie
potable WIRSBO AQUAPEX 1/2”, bagues de retenue à expansion à froid Uponor ProPEX 1/2” et l’outil d’expansion
manuel Uponor ProPEX conformément aux instructions d’Uponor.
AVIS IMPORTANT AUX INSTALLATEURS! Remplir les vides dans
la boîte d’information ci-dessous. Conserver ce guide pour référence
future.
AVIS AUX PROPRIÉTAIRES! Ce dispositif a été pré-réglé par
_______________________ de _______________________________ pour
assurer une température maximale sécurisée. Toute modification de ce
réglage peut augmenter la température d’évacuation au-delà de la
limite considérée comme étant sécuritaire et causer des brûlures.
Date: ______________
089585-2-BE Français-2 Kallista

INSTRUCTIONS IMPORTANTES (cont.)
Outils et matériaux
Avant de commencer
ATTENTION: Risque de blessures. La température de l’eau
ne doit jamais être réglée à une température supérieure à
120°F (49°C).
AVIS: Seulement utiliser un tuyau en cuivre de 1/2″(Dia. ext. 5/8″)
(type L ou M) entre la vanne et le bec de la baignoire. L’utilisation
d’autres matériaux pourrait créer une surpression et résulter en un
écoulement d’eau simultané en provenance du bec de la pomme de
la douche et de la baignoire.
AVIS: Certaines installations exigent que les dimensions de
raccordement de la garniture de robinetterie soient différentes de
celles indiquées dans ce guide. Se reporter à la fiche de
spécifications de la garniture de robinetterie pour confirmer les
dimensions.
AVIS: Ne pas forcer la poignée dans une quelconque direction. Le
robinet subira des dommages si la poignée est forcée.
Respecter tous les codes de plomberie et de bâtiment locaux.
Couper l’alimentation en eau principale.
Clé à sangle
Ruban
d'étanchéité
SouderOutil d'assertissage
PEX (Optionnel)
Clé hexagonale
Scie à métaux
ou coupe tubes
Outil d'expansion
de froid
Kallista Français-3 089585-2-BE

Avant de commencer (cont.)
Kallista se réserve le droit d’effectuer des modifications dans le
design des robinets sans avis préalable, tel que spécifié dans le
catalogue des prix.
089585-2-BE Français-4 Kallista
Table of contents
Languages:
Other Kallista Control Unit manuals