Kamic Installation ZEUS4-VD User guide

ZEUS4-VD
VOICE & SMS GSM ALARM
COMMUNICATOR
INSTALLER’S MANUAL
V 1.0

ZEUS-VD INSTALLER’S MANUAL
TABLE OF CONTENTS
1FOR YOUR SAFETY.............................................................................................................................................1
2FEATURES .............................................................................................................................................................2
3DESCRIPTION.......................................................................................................................................................3
4PURPOSE AND APPLICATION..........................................................................................................................4
5START UP...............................................................................................................................................................5
6LED DISPLAY........................................................................................................................................................6
7CONNECTING DIAGRAM ..................................................................................................................................7
8VOICE MESSAGES – RECORD & PLAY..........................................................................................................8
8.1 RECORDING MODE.....................................................................................................................................................................8
8.2 PLAY.......................................................................................................................................................................................8
9ZEUS4-VD PROGRAMMING MODE.................................................................................................................9
9.1 PROGRAMMING TELEPHONE NUMBERS -TN ...............................................................................................................9
9.1.1 TN remote programming by SMS ............................................................................................................10
9.2 PROGRAMMING INPUT STATUS -IN..............................................................................................................................10
9.2.1 IN parameter remote programming by SMS.............................................................................................11
9.3 DELAY BEFORE DIAL –DD .....................................................................................................................................................11
9.3.1 DD remote programming by SMS............................................................................................................12
9.4 INPUT FILTER PARAMETR –ID.......................................................................................................................................13
9.4.1 Programming table to define the value of the input filter .........................................................................13
9.4.2 ID parameter remote programming by SMS.............................................................................................13
9.5 PROGRAMMING OUTPUT STATUS -OS ..........................................................................................................................14
9.5.1 Programming table for output status.........................................................................................................14
9.5.2 OS remote programming by SMS.............................................................................................................14
9.6 DIRECT ALARM OUTPUT –OD........................................................................................................................................15
9.6.1 Programming table for OD – direct alarm output.....................................................................................15
9.6.2 OD remote programming by SMS............................................................................................................16
9.7 INPUTS AND TELEPHONE NUMBERS LINKING...........................................................................................................16
9.7.1 Programming table for linking the inputs and telephone numbers – LN..................................................16
9.7.2 LN remote programming by SMS ............................................................................................................17
9.8 MAIN POWER LOST AND TELEPHONE NO.LINKING –LN5 .......................................................................................17
9.8.1 Programming table for the MAIN POWER LOST and telephone numbers linking.................................18
9.8.2 LN remote programming by SMS ............................................................................................................18
9.9 LOW BATTERY AND TELEPHONE NO.LINKING –LN6 ...............................................................................................18
9.9.1 Programming table for LOW BATTERY and telephone numbers linking...............................................18
9.9.2 LN6 remote programming by SMS ..........................................................................................................19
9.10 MAIN POWER LOST FILTERLTER PARAMETR -MAIN ..........................................................................................19
9.10.1 Programming table for “MAIN POWER LOST” filter – MAIN..............................................................19
9.10.2 “MAIN POWER LOST” filter remote programming by SMS.................................................................19
9.11 CLIP FUNCTION PARAMETER –TC ................................................................................................................................20
9.11.1 Programming table to define the CLIP functions – TC ............................................................................20
9.11.2 TC parameter remote programming by SMS............................................................................................21
9.12 INPUT TIME WINDOW –IT ..........................................................................................................................................21

ZEUS-VD INSTALLER’S MANUAL
9.12.1 The input time window remote programming by SMS.............................................................................21
9.13 INPUT TRIGGER COUNTER BEFORE BLOCK -AR ..................................................................................................23
9.13.1 The input trigger counter before block remote programming by SMS.....................................................23
9.14 SECURITY LEVEL -SL..................................................................................................................................................24
9.14.1 Programming table for security level definition – SL...............................................................................24
9.14.2 SL parameter remote programming by SMS............................................................................................24
9.15 PRE-PAY CARD CREDIT AND VALIDITY INFORMATION.....................................................................................25
9.15.1 Programming pre pay card credit and validity string................................................................................25
9.15.2 CC parameter for remote programming....................................................................................................25
9.16 ZEUS4-VD SET-UP PARAMERTERS...........................................................................................................................26
9.16.1 Set-up parameters programming by SMS.................................................................................................27
9.17 SMS MESSAGES EDITOR.............................................................................................................................................28
9.17.1 Alarm messages remote editing by SMS command..................................................................................28
10 ZEUS4-VD DTMF REMOTE COMMANDS.....................................................................................................29
10.1 DTMF REMOTE COMMAND TABLE ..........................................................................................................................29
11 PRINT-OUT OF THE PARAMETERS..............................................................................................................30
11.1.1 Receive all parameters (PALL).................................................................................................................30
11.1.2 Receive telephone numbers (PTN)...........................................................................................................30
11.1.3 Receive links (PLN)..................................................................................................................................30
11.1.4 Receive input parameters (PIN)................................................................................................................30
11.1.5 Receive input filter value (PID)................................................................................................................30
11.1.6 Receive delay before dial value (PDD).....................................................................................................30
11.1.7 Receive clip identification functions (PTC)..............................................................................................30
11.1.8 Receive access telephone numbers (PSL).................................................................................................31
11.1.9 Receive output parameters (POS).............................................................................................................31
11.1.10 Receive link for local alarm output (POD)...............................................................................................31
11.1.11 Receive all programmed SMS messages (P#) ..........................................................................................31
11.1.12 Receive the power level on the unit (PPWR)............................................................................................31
11.1.13 Receive set up parameters value (PPA)....................................................................................................31
11.1.14 State of the credit for the PRE-PAY CARD.............................................................................................31
11.1.15 State of the outputs (PORC) .....................................................................................................................32
12 CHECKING AND CHANGING THE SYSTEM STATUS (ON/OFF)............................................................33
12.1 CHECKING SYSTEM STATUS BY SMS COMMAND ................................................................................................33
12.2 CHECKING SYSTEM STATUS BY DTMF COMMAND .............................................................................................33
12.3 CHANGING SYSTEM STATUS OFF TO ON (SYSTEM ON) .......................................................................................33
12.4 CHANGING SYSTEM STATUS ON TO OFF (SYSTEM OFF)......................................................................................33
13 CHECKING THE INPUT STATUS ...................................................................................................................34
13.1 CHECKING THE INPUT STATUS BY DTMF...............................................................................................................34
13.2 CHECKING THE INPUT STATUS BY SMS (INS)........................................................................................................34
14 OUTPUTS REMOTE CONTROL......................................................................................................................35
14.1 OUTPUTS REMOTE CONTROL BY SMS COMMAND...............................................................................................35
14.2 OUTPUTS REMOTE CONTROL BY DTMF COMMAND............................................................................................35
15 CLEAR ALL PROGRAMMED DATA FROM SIM ........................................................................................36
16 CHANGEING PARAMETERS USING THE SMS COMMAND....................................................................37
TECHNICAL SPECIFICATION .................................................................................................................................38
17 CONTACTS ..........................................................................................................................................................39

ZEUS-VD INSTALLER’S MANUAL
1FOR YOUR SAFETY
Read these simple guidelines. Not following them may be dangerous or illegal. Read the complete
user guide for further information.
SWITCH ON SAFELY
Do not switch the unit on when wireless phone use is prohibited or when it may cause interference
or danger.
INTERFERENCE
All wireless phones and units may be susceptible to interference, which could affect performance.
SWITCH OFF IN HOSPITALS
Follow any restrictions. Switch the unit off near medical equipment.
SWITCH OFF IN AIRCRAFT
Follow any restrictions. Wireless devices can cause interference in aircraft.
SWITCH OFF WHEN REFUELING
Do not use the unit at a refueling point. Do not use near fuel or chemicals.
SWITCH OFF NEAR BLASTING
Follow any restrictions. Do not use the unit where blasting is in progress.
USE SENSIBLY
Page 1
Use only in the normal position as explained in the product documentation. Do not touch the
antenna unnecessarily.

ZEUS-VD INSTALLER’S MANUAL
2FEATURES
⇒Built in GSM module
⇒4 alarm inputs
⇒4 remote control alarm outputs
⇒Pre-recorded alarm messages – 1 for each alarm input
⇒SMS for each alarm input
⇒Memory stores up to 10 different telephone numbers
⇒Dialing of telephone number sequences can be programmed
⇒Listen-in function
⇒LED displays enable easy monitoring
⇒Already activated dialing sequence can be stopped by means of user's telephone unit
⇒Download programming by SMS
⇒Input and Output status checking by SMS and DTMF command
⇒Outputs remote control by SMS, CLIP and DTMF command
⇒System activating and deactivating by SMS, CLIP and DTMF command
⇒Phone book memory clear by SMS command
⇒Full print out of programming parameters by SMS
⇒Print out by parameters groups (14 groups)
⇒Pre-pay cards credit and value checking
⇒Security protected for incoming calls
⇒Call back device checking Manual fix of the GSM network
⇒Easy new firmware downloads with the ISP programming cable
⇒Event log with the time stamp
Page 2

ZEUS-VD INSTALLER’S MANUAL
3DESCRIPTION
The ZEUS4-VD-GSM is a new kind of a mobile voice and SMS dialing system. The phone
memory in the form of a SIM card is used either to store telephone numbers or to program certain
parameters. The alarm event is possible send on to 10 different telephone numbers. The alarm
inputs can be normal open (N.O.) and are thus triggered by a positive (+12V) or a negative pulse
(GND); or they can be normal close (+12V or GND lost). Each alarm input enables us to send an
alarm recorded voice message, the SMS message or both.
Page 3
The ZEUS4-VD has also four outputs giving the user the ability to control a certain system from
distance by DTMF, SMS or CLIP command

ZEUS-VD INSTALLER’S MANUAL
4PURPOSE AND APPLICATION
The ZEUS4-VD mobile device can provide us with different information on the state of the alarm
mounted on the protected object. It can also transmit other useful information important for
operating applications such as:
⇒vending machines
⇒fire systems
⇒security alarm systems
⇒various engines out of the reach of manual operation
⇒home care or emergency alarm
⇒car and boat alarm transmitter
⇒temperature regulation by means of a sensor
⇒industrial control applications
Page 4

ZEUS-VD INSTALLER’S MANUAL
5START UP
⇒Insert SIM card to be used for ZEUS4-VD in your personal mobile phone.
⇒ERASE THE PIN CODE!
⇒Enter telephone numbers and the required operating parameters in SIM memory – at least 1
telephone No. (TN1) and 1 link (LN1) should be programmed (see installer’s manual)
⇒Insert SIM card in the GSM module applied for the ZEUS4-VD device. The unit must be
power OFF when you insert the SIM!
⇒Connect alarm inputs and outputs to ZEUS4-VD
⇒Connect the antenna to antenna connector
⇒Connect device to source power supply voltage
⇒Wait until LED3 display is turned ON (green) and LED1 (blue) starts flashing. This will be
set in around 1 minute time.
⇒Connect the headset to Play/REC connector and record alarm messages
⇒ZEUS4-VD unit is now ready for operate.
NOTE:
When the back-up battery 12V/1,2Ah is connected on the unit the main power supply must be
from 13,8V to 14,5V DC!
Page 5

ZEUS-VD INSTALLER’S MANUAL
6LED DISPLAY
Blue LED (LED1)
–Indicate the level of the GSM signal from 1-5 LED flash (1 = weak signal, 5 excellent
signal)
Red LED (LED2)
-When the LED 2 is ON the unit has a problem with a GSM network connection or the GSM
part of the unit is out of order. In this case immediately call the service!
Red LED (LED2) – alarm state
-During alarm event the RED led will indicate on which input alarm is. For example, for the
first input you’ll see 1 flash, second input 2 fleshes etc.
Green LED (LED3)
-When the alarm inputs on the unit are in active state (SYS=1) then the green LED is ON.
With inputs disabling the green LED goes OFF (SYS=0).
Yellow LED (LED4)
-Short flashing indicate that the GSM module is ON but it is not yet connect on the GSM
network. After connection yellow led flashing with short pulse ON and a long pulse OFF.
Page 6

ZEUS-VD INSTALLER’S MANUAL
7CONNECTING DIAGRAM
Page 7
Output 1
Output 2
Output 3
Output 4
Ground
Ground
+13,8V DC
+12V Batt
Tamper switch
Input 1
Input 2
Input 3
Input 4
Ground
ON/OFF
USB
+12VAUX
SIM
contacts down
Play/REC audio connector
Listen in connector
ISP programming connector
lpc2368
NXP
ARM7
microcontroller
Play/REC switch
RecordingLED
USB connector
SIM card
LEDmonitor
Service connector
Table of contents
Popular Security System manuals by other brands

EDM
EDM Solution 6+6 Wireless-AE installation manual

Highway Safety Group
Highway Safety Group EA401 user manual

Siren
Siren LED GSM operating manual

Detection Systems
Detection Systems 7090i Installation and programming manual

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 instructions

Siemens
Siemens FDM273 manual