Kamic Installation ZEUS4-VD User guide

ZEUS4-VD
VOICE & SMS GSM ALARM
COMMUNICATOR
INSTALLER’S MANUAL
V 1.0

ZEUS-VD INSTALLER’S MANUAL
TABLE OF CONTENTS
1FOR YOUR SAFETY.............................................................................................................................................1
2FEATURES .............................................................................................................................................................2
3DESCRIPTION.......................................................................................................................................................3
4PURPOSE AND APPLICATION..........................................................................................................................4
5START UP...............................................................................................................................................................5
6LED DISPLAY........................................................................................................................................................6
7CONNECTING DIAGRAM ..................................................................................................................................7
8VOICE MESSAGES – RECORD & PLAY..........................................................................................................8
8.1 RECORDING MODE.....................................................................................................................................................................8
8.2 PLAY.......................................................................................................................................................................................8
9ZEUS4-VD PROGRAMMING MODE.................................................................................................................9
9.1 PROGRAMMING TELEPHONE NUMBERS -TN ...............................................................................................................9
9.1.1 TN remote programming by SMS ............................................................................................................10
9.2 PROGRAMMING INPUT STATUS -IN..............................................................................................................................10
9.2.1 IN parameter remote programming by SMS.............................................................................................11
9.3 DELAY BEFORE DIAL –DD .....................................................................................................................................................11
9.3.1 DD remote programming by SMS............................................................................................................12
9.4 INPUT FILTER PARAMETR –ID.......................................................................................................................................13
9.4.1 Programming table to define the value of the input filter .........................................................................13
9.4.2 ID parameter remote programming by SMS.............................................................................................13
9.5 PROGRAMMING OUTPUT STATUS -OS ..........................................................................................................................14
9.5.1 Programming table for output status.........................................................................................................14
9.5.2 OS remote programming by SMS.............................................................................................................14
9.6 DIRECT ALARM OUTPUT –OD........................................................................................................................................15
9.6.1 Programming table for OD – direct alarm output.....................................................................................15
9.6.2 OD remote programming by SMS............................................................................................................16
9.7 INPUTS AND TELEPHONE NUMBERS LINKING...........................................................................................................16
9.7.1 Programming table for linking the inputs and telephone numbers – LN..................................................16
9.7.2 LN remote programming by SMS ............................................................................................................17
9.8 MAIN POWER LOST AND TELEPHONE NO.LINKING –LN5 .......................................................................................17
9.8.1 Programming table for the MAIN POWER LOST and telephone numbers linking.................................18
9.8.2 LN remote programming by SMS ............................................................................................................18
9.9 LOW BATTERY AND TELEPHONE NO.LINKING –LN6 ...............................................................................................18
9.9.1 Programming table for LOW BATTERY and telephone numbers linking...............................................18
9.9.2 LN6 remote programming by SMS ..........................................................................................................19
9.10 MAIN POWER LOST FILTERLTER PARAMETR -MAIN ..........................................................................................19
9.10.1 Programming table for “MAIN POWER LOST” filter – MAIN..............................................................19
9.10.2 “MAIN POWER LOST” filter remote programming by SMS.................................................................19
9.11 CLIP FUNCTION PARAMETER –TC ................................................................................................................................20
9.11.1 Programming table to define the CLIP functions – TC ............................................................................20
9.11.2 TC parameter remote programming by SMS............................................................................................21
9.12 INPUT TIME WINDOW –IT ..........................................................................................................................................21

ZEUS-VD INSTALLER’S MANUAL
9.12.1 The input time window remote programming by SMS.............................................................................21
9.13 INPUT TRIGGER COUNTER BEFORE BLOCK -AR ..................................................................................................23
9.13.1 The input trigger counter before block remote programming by SMS.....................................................23
9.14 SECURITY LEVEL -SL..................................................................................................................................................24
9.14.1 Programming table for security level definition – SL...............................................................................24
9.14.2 SL parameter remote programming by SMS............................................................................................24
9.15 PRE-PAY CARD CREDIT AND VALIDITY INFORMATION.....................................................................................25
9.15.1 Programming pre pay card credit and validity string................................................................................25
9.15.2 CC parameter for remote programming....................................................................................................25
9.16 ZEUS4-VD SET-UP PARAMERTERS...........................................................................................................................26
9.16.1 Set-up parameters programming by SMS.................................................................................................27
9.17 SMS MESSAGES EDITOR.............................................................................................................................................28
9.17.1 Alarm messages remote editing by SMS command..................................................................................28
10 ZEUS4-VD DTMF REMOTE COMMANDS.....................................................................................................29
10.1 DTMF REMOTE COMMAND TABLE ..........................................................................................................................29
11 PRINT-OUT OF THE PARAMETERS..............................................................................................................30
11.1.1 Receive all parameters (PALL).................................................................................................................30
11.1.2 Receive telephone numbers (PTN)...........................................................................................................30
11.1.3 Receive links (PLN)..................................................................................................................................30
11.1.4 Receive input parameters (PIN)................................................................................................................30
11.1.5 Receive input filter value (PID)................................................................................................................30
11.1.6 Receive delay before dial value (PDD).....................................................................................................30
11.1.7 Receive clip identification functions (PTC)..............................................................................................30
11.1.8 Receive access telephone numbers (PSL).................................................................................................31
11.1.9 Receive output parameters (POS).............................................................................................................31
11.1.10 Receive link for local alarm output (POD)...............................................................................................31
11.1.11 Receive all programmed SMS messages (P#) ..........................................................................................31
11.1.12 Receive the power level on the unit (PPWR)............................................................................................31
11.1.13 Receive set up parameters value (PPA)....................................................................................................31
11.1.14 State of the credit for the PRE-PAY CARD.............................................................................................31
11.1.15 State of the outputs (PORC) .....................................................................................................................32
12 CHECKING AND CHANGING THE SYSTEM STATUS (ON/OFF)............................................................33
12.1 CHECKING SYSTEM STATUS BY SMS COMMAND ................................................................................................33
12.2 CHECKING SYSTEM STATUS BY DTMF COMMAND .............................................................................................33
12.3 CHANGING SYSTEM STATUS OFF TO ON (SYSTEM ON) .......................................................................................33
12.4 CHANGING SYSTEM STATUS ON TO OFF (SYSTEM OFF)......................................................................................33
13 CHECKING THE INPUT STATUS ...................................................................................................................34
13.1 CHECKING THE INPUT STATUS BY DTMF...............................................................................................................34
13.2 CHECKING THE INPUT STATUS BY SMS (INS)........................................................................................................34
14 OUTPUTS REMOTE CONTROL......................................................................................................................35
14.1 OUTPUTS REMOTE CONTROL BY SMS COMMAND...............................................................................................35
14.2 OUTPUTS REMOTE CONTROL BY DTMF COMMAND............................................................................................35
15 CLEAR ALL PROGRAMMED DATA FROM SIM ........................................................................................36
16 CHANGEING PARAMETERS USING THE SMS COMMAND....................................................................37
TECHNICAL SPECIFICATION .................................................................................................................................38
17 CONTACTS ..........................................................................................................................................................39

ZEUS-VD INSTALLER’S MANUAL
1FOR YOUR SAFETY
Read these simple guidelines. Not following them may be dangerous or illegal. Read the complete
user guide for further information.
SWITCH ON SAFELY
Do not switch the unit on when wireless phone use is prohibited or when it may cause interference
or danger.
INTERFERENCE
All wireless phones and units may be susceptible to interference, which could affect performance.
SWITCH OFF IN HOSPITALS
Follow any restrictions. Switch the unit off near medical equipment.
SWITCH OFF IN AIRCRAFT
Follow any restrictions. Wireless devices can cause interference in aircraft.
SWITCH OFF WHEN REFUELING
Do not use the unit at a refueling point. Do not use near fuel or chemicals.
SWITCH OFF NEAR BLASTING
Follow any restrictions. Do not use the unit where blasting is in progress.
USE SENSIBLY
Page 1
Use only in the normal position as explained in the product documentation. Do not touch the
antenna unnecessarily.

ZEUS-VD INSTALLER’S MANUAL
2FEATURES
⇒Built in GSM module
⇒4 alarm inputs
⇒4 remote control alarm outputs
⇒Pre-recorded alarm messages – 1 for each alarm input
⇒SMS for each alarm input
⇒Memory stores up to 10 different telephone numbers
⇒Dialing of telephone number sequences can be programmed
⇒Listen-in function
⇒LED displays enable easy monitoring
⇒Already activated dialing sequence can be stopped by means of user's telephone unit
⇒Download programming by SMS
⇒Input and Output status checking by SMS and DTMF command
⇒Outputs remote control by SMS, CLIP and DTMF command
⇒System activating and deactivating by SMS, CLIP and DTMF command
⇒Phone book memory clear by SMS command
⇒Full print out of programming parameters by SMS
⇒Print out by parameters groups (14 groups)
⇒Pre-pay cards credit and value checking
⇒Security protected for incoming calls
⇒Call back device checking Manual fix of the GSM network
⇒Easy new firmware downloads with the ISP programming cable
⇒Event log with the time stamp
Page 2

ZEUS-VD INSTALLER’S MANUAL
3DESCRIPTION
The ZEUS4-VD-GSM is a new kind of a mobile voice and SMS dialing system. The phone
memory in the form of a SIM card is used either to store telephone numbers or to program certain
parameters. The alarm event is possible send on to 10 different telephone numbers. The alarm
inputs can be normal open (N.O.) and are thus triggered by a positive (+12V) or a negative pulse
(GND); or they can be normal close (+12V or GND lost). Each alarm input enables us to send an
alarm recorded voice message, the SMS message or both.
Page 3
The ZEUS4-VD has also four outputs giving the user the ability to control a certain system from
distance by DTMF, SMS or CLIP command

ZEUS-VD INSTALLER’S MANUAL
4PURPOSE AND APPLICATION
The ZEUS4-VD mobile device can provide us with different information on the state of the alarm
mounted on the protected object. It can also transmit other useful information important for
operating applications such as:
⇒vending machines
⇒fire systems
⇒security alarm systems
⇒various engines out of the reach of manual operation
⇒home care or emergency alarm
⇒car and boat alarm transmitter
⇒temperature regulation by means of a sensor
⇒industrial control applications
Page 4

ZEUS-VD INSTALLER’S MANUAL
5START UP
⇒Insert SIM card to be used for ZEUS4-VD in your personal mobile phone.
⇒ERASE THE PIN CODE!
⇒Enter telephone numbers and the required operating parameters in SIM memory – at least 1
telephone No. (TN1) and 1 link (LN1) should be programmed (see installer’s manual)
⇒Insert SIM card in the GSM module applied for the ZEUS4-VD device. The unit must be
power OFF when you insert the SIM!
⇒Connect alarm inputs and outputs to ZEUS4-VD
⇒Connect the antenna to antenna connector
⇒Connect device to source power supply voltage
⇒Wait until LED3 display is turned ON (green) and LED1 (blue) starts flashing. This will be
set in around 1 minute time.
⇒Connect the headset to Play/REC connector and record alarm messages
⇒ZEUS4-VD unit is now ready for operate.
NOTE:
When the back-up battery 12V/1,2Ah is connected on the unit the main power supply must be
from 13,8V to 14,5V DC!
Page 5

ZEUS-VD INSTALLER’S MANUAL
6LED DISPLAY
Blue LED (LED1)
–Indicate the level of the GSM signal from 1-5 LED flash (1 = weak signal, 5 excellent
signal)
Red LED (LED2)
-When the LED 2 is ON the unit has a problem with a GSM network connection or the GSM
part of the unit is out of order. In this case immediately call the service!
Red LED (LED2) – alarm state
-During alarm event the RED led will indicate on which input alarm is. For example, for the
first input you’ll see 1 flash, second input 2 fleshes etc.
Green LED (LED3)
-When the alarm inputs on the unit are in active state (SYS=1) then the green LED is ON.
With inputs disabling the green LED goes OFF (SYS=0).
Yellow LED (LED4)
-Short flashing indicate that the GSM module is ON but it is not yet connect on the GSM
network. After connection yellow led flashing with short pulse ON and a long pulse OFF.
Page 6

ZEUS-VD INSTALLER’S MANUAL
7CONNECTING DIAGRAM
Page 7
Output 1
Output 2
Output 3
Output 4
Ground
Ground
+13,8V DC
+12V Batt
Tamper switch
Input 1
Input 2
Input 3
Input 4
Ground
ON/OFF
USB
+12VAUX
SIM
contacts down
Play/REC audio connector
Listen in connector
ISP programming connector
lpc2368
NXP
ARM7
microcontroller
Play/REC switch
RecordingLED
USB connector
SIM card
LEDmonitor
Service connector

ZEUS-VD INSTALLER’S MANUAL
8VOICE MESSAGES – RECORD & PLAY
The memory of each alarm input enables us to record our own voice message in the total length of
10 seconds. The device is namely equipped with a Play/Record audio connector. For recording and
listen recorded message the headset is necessary. The headset is very common and it is use with
many mobile phones but should be supplied also by your distributor.
8.1 RECORDING MODE
For recording and playing alarm messages the ZEUS4 has a joystick switch which you can use in 4
different directions:
Message 1 – UP
Message 2 – RIGHT
Message 3 – DOWN
Message 4 – LEFT
message 1
message 4
message 3
message 2
To start recording mode push the Play/REC joystick in to one direction (depending which message
you’d like to record) and hold the stick in this position. After the beep you can start with recording
and stop recording when you’ll here two short beeps. The REC/Play procedure is indicating by
REC/Play LED as well. The REC/Play LED will flashing during recording or playing procedure.
Follow the same procedure for all four alarm messages.
8.2 PLAY
Press the PLAY/REC joystick into one direction for a short time (around 1 second) and you will
here the recorded message.
To stop play mode press the Play/REC joystick again for a second and play mode will stop.
Page 8
Follow the same procedure for all four messages.

ZEUS-VD INSTALLER’S MANUAL
9ZEUS4-VD PROGRAMMING MODE
All data, programming values and telephone numbers need to be stored in the phone book located
on the SIM card. The ZEUS4-VD is possible to program on 4 different ways:
⇒Using the USB SIM manager on the PC - recommended
⇒directly on SIM card using personal mobile phone
⇒Remotely by SMS command
⇒With PC Via USB port*
* not supported yet
NOTE:
The PIN number on the SIM card must be erasing before programming procedure!!!
Disconnects the power supply from the unit when remove or insert the SIM card!
9.1 PROGRAMMING TELEPHONE NUMBERS - TN
PROGRAMMING TABLE – DIRECT PROGRAMMING ON THE SIM CARD
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name Phone (Number) Description
TN1 1s
t
telephone number
TN2 2n
d
telephone number
TN3 3r
d
telephone number
TN4 4th telephone number
TN5 5th telephone number
TN6 6th telephone number
TN7 7th telephone number
TN8 8th telephone number
TN9 9th telephone number
TN0 10th telephone number
ZEUS4-VD send an alarm recorded voice message, an alarm SMS message or both. If the
corresponding name ends with the letter “V”, when only voice message is sent; and if the name
ends with the letter “M”, only the SMS message is sent. When the name ends with letter “D” the
unit will be use for the door entry system.
By pressing the * you will switch off the redial call for calling number. The remaining
numbers will be called as usual.
By pressing the # you will switch off all remaining calls.
Example: When you need sending an alarm voice message and the SMS message to the first
telephone number, only alarm voice message to the second one and only an SMS message to the
third one. (See the table below.)
Page 9

ZEUS-VD INSTALLER’S MANUAL
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name Number Description
TN1
1st telephone number (alarm beep & SMS message)
TN2V 040719479 2nd telephone number (alarm beep only)
TN3M 040308350 3rd telephone number (SMS message only)
9.1.1 TN remote programming by SMS
For the upper example send the following SMS from the host phone to the ZEUS4-VD:
;TN1=042376678 ;TN2V=040719479;TN3M=040308350;
If you want to get the confirmation SMS back then write “+” before SMS command:
;+TN1=042376678 ;TN2V=040719479;TN3M=040308350;
9.2 PROGRAMMING INPUT STATUS - IN
Alarm and reset input can be triggered in 4 different ways. The status of the input can either be
normal closed (N.C) or normal open (N.O.) with positive (+ 12V) or negative (GND) voltage.
When you need the input feed back information it is possible to get SMS back when input will
return from alarm to normal position. (See cap.5.8 – SMS Messages organizer). To get return SMS
use IN=4,5 or 6.
⇒IN = 0 – Normal Open – triggered with negative voltage (GND)
⇒IN = 1 – Normal Close – breaking negative or positive voltage loop
⇒IN = 2 – Normal Open – triggered with positive voltage (+ 12VDC)
⇒IN = 3 – Input disable
⇒IN = 4 = IN = 0 + input reset SMS
⇒IN = 5 = IN = 1 + input reset SMS
⇒IN = 6 = IN = 2 + input reset SMS
TYPICAL INPUT CONNECTIONS
GND
INPUT 1-4
N.O.
contact
+12VDC
INPUT 1-4
N.O.
contact
GND
1-4INPUT
N.C.
contact
+12VDC
INPUT 1-4
N.O.
contact
Page 10

ZEUS-VD INSTALLER’S MANUAL
PROGRAMMING TABLE FOR INPUT STATUS
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name Default Description
ION 0
Input status for system ON/OFF
IN1 0
Input status for alarm input 1
IN2 0
Input status for alarm input 2
IN3 0
Input status for alarm input 3
IN4 0
Input status for alarm input 4
Example:
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name Number Description
ION 0
OFF – connecting GND on ON/OFF input
IN1 0
Alarm activated by connecting to GND
IN2 1
Alarm activated by disconnecting GND or +12V
IN3 2
Alarm activated by connecting +12V
IN4 4
Alarm activated by connecting to GND + RST SMS
9.2.1 IN parameter remote programming by SMS
For the upper example send the following SMS from the host phone to the ZEUS4-VD:
;ION=0;IN1=0;IN2=1;IN3=2;IN4=4;
If you want to get the confirmation SMS back then write “+” before SMS command:
;+ION=0;IN1=0;IN2=1;IN3=2;IN4=4;
9.3 DELAY BEFORE DIAL – DD
When you want to use some delay before unit will start dialing procedure then you will use DD –
delay before dialing parameter.
Page 11
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name Number Description
DDN
ON/OFF input delay
DD1
Delay before dialing for Input 1
DD2
Delay before dialing for Input 2
DD3
Delay before dialing for Input 3
DD4
Delay before dialing for Input 4

ZEUS-VD INSTALLER’S MANUAL
Example:
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name Number Description
DDN 15
15 seconds delay for ON/OFF input
DD1 5
5 seconds delay before dialing for Input 1
DD2 0
No delay before dialing for Input 2
DD3 0
No delay before dialing for Input 3
DD4 10
10 seconds delay before dialing for Input 4
9.3.1 DD remote programming by SMS
For the upper example send the following SMS from the host phone to the ZEUS4-VD:
;DDN=15;DD1=5;DD2=0;DD3=0;DD4=10;
If you want to get the confirmation SMS back then write “+” before SMS command:
Page 12
;+DDDONN=15;DD1=5;DD2=0;DD3=0;DD4=10;

ZEUS-VD INSTALLER’S MANUAL
9.4 INPUT FILTER PARAMETR – ID
The ID parameter determine time period of the pulse length to trigger the Input. The pulse time can
be from 0, 5 second up to 9999 seconds. The default time is 0,5 seconds when the parameter value
is 0.
9.4.1 Programming table to define the value of the input filter
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name Number (default) Description
DON 0
Default ID filter is 0,5 second – ON/OFF input
ID1 0
Default ID filter is 0,5 second – input 1
ID2 0
Default ID filter is 0,5 second – input 2
ID3 0
Default ID filter is 0,5 second – input 3
ID4 0
Default ID filter is 0,5 second – input 4
Example:
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name Number (default) Description
DON 0
Default ID filter is 0,5 second – ON/OFF input
ID1 0
ID filter is 5 seconds for input 1
ID2 0
ID filter is 30 seconds for input 2
ID3 0
ID filter is 2 seconds for input 3
ID4 0
ID filter is 0,5 second for input 4
9.4.2 ID parameter remote programming by SMS
For the upper example send the following SMS from the host phone to the ZEUS4-VD:
;ID1=5;ID2=30;ID3=2;ID4=0;
If you want to get the confirmation SMS back then write “+” before SMS command:
;+ID1=5;ID2=30;ID3=2;ID4=0;
Page 13

ZEUS-VD INSTALLER’S MANUAL
9.5 PROGRAMMING OUTPUT STATUS - OS
The ZEUS4-VD device has four open collector outputs and each of them can be programmed
through network in a different way: as a bi-stable or mono-stable (pulse) output. The programming
time is in seconds.
Typical connection for the output:
+12V DC
OUTPUT 1-4
R 1K
LED
+12V DC
1-4OUTPUT
RELAY
12V DC
9.5.1 Programming table for output status
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name Number (default) Description
OS1 1
Status for the 1st output – enabled
OS2 1
Status for the 2nd output – enabled
OS3 1
Status for the 3rd output – enabled
OS4 1
Status for the 4th output – enabled
Example:
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name Number Description
OS1 1
ON/OFF mode output
OS2 0
Disabled output
OS3 20
20 second pulse output
OS4 5
5 second pulse output
9.5.2 OS remote programming by SMS
For the upper example send the following SMS from the host phone to the ZEUS4-VD:
;OS1=1;OS2=0;OS3=20;OS4=5;
If you want to get the confirmation SMS back then write “+” before SMS command:
;+OS1=1;OS2=0;OS3=20;OS4=5;
Page 14

ZEUS-VD INSTALLER’S MANUAL
9.6 DIRECT ALARM OUTPUT – OD
If you want to activate a local alarm (siren) you can program any ZEUS4-VD output for this
function. OD5 to OD8 are links between fictive inputs like telephone line failure, GSM failure to
dedicated output.
Type of the Output (ON/OFF or pulse time) is determinate with parameter OS.
In the same time you can control the outputs also remotely by SMS or DTMF commands.
Possible programming parameters:
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name Output Description
OD1
N
o direct connection between input and outpu
t
OD2
N
o direct connection between input and outpu
t
OD3
N
o direct connection between input and outpu
t
OD4
N
o direct connection between input and outpu
t
OD5
Telephone line failure (ONLY MC version)
OD6
GSM network failure
OD7
System tamper
OD8
System ON/OFF (any of outputs)
9.6.1 Programming table for OD – direct alarm output
Example:
It is possible to choose different combinations between outputs and inputs
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name Output Description
OD1 1
Alarm on IN1 trigger output 1
OD2 0
N
o direct connection between input and outpu
t
OD3 0
N
o direct connection between input and outpu
t
OD4 0
N
o direct connection between input and output
OD5 X
Telephone line failure (ONLY MC version)
OD6 2
GSM network failure on output 2
OD7 4
System tamper on output 4
OD8 3
System ON/OFF on output 3
Page 15

ZEUS-VD INSTALLER’S MANUAL
9.6.2 OD remote programming by SMS
For the upper example send the following SMS from the host phone to the ZEUS4-VD:
;OD1=1;OD6=2;OD7=4;OD8=3;
If you want to get the confirmation SMS back then write “+” before SMS command:
;+OD1=1;OD6=2;OD7=4;OD8=3;
9.7 INPUTS AND TELEPHONE NUMBERS LINKING
It is possible to link each number or any combination of numbers to any of the four corresponding
inputs.
9.7.1 Programming table for linking the inputs and telephone numbers – LN
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name Number (default) Description
LN1 Input & telephone No. linking for 1s
t
alarm input (TN1 – TN0)
LN2 Input & telephone No. linking for 2n
d
alarm input (TN1 – TN0)
LN3 Input & telephone No. linking for 3r
d
alarm input (TN1 – TN0)
LN4 Input & telephone No. linking for 4th alarm input (TN1 – TN0)
LN5 Power down and telephone No. linking (TN1 – TN0)
LN6 Low Battery and telephone No. Linking (TN1 – TN0)
LN7 Periodic test SMS and telephone No. linking (TN1 – TN0)
LN8 SIM card refill and telephone No. linking (TN1 – TN0)
LN9 Tamper switch and telephone No. linking (TN1 – TN0)
Example:
Page 16
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name Number Description
LN8 12 Refill SIM – SMS will be send to TN1 & TN2
LN1 13 Input1 will call/send SMS to TN1 & TN3
LN2 123 Input2 will call/send SMS to TN1, TN2 & TN3
LN3 5 Input3 will call/send SMS to TN5
LN4 45 Input4 will call/send SMS to send to TN4 & TN5
LN7 12 Periodic Test SMS will be send to TN1 & TN2

ZEUS-VD INSTALLER’S MANUAL
9.7.2 LN remote programming by SMS
For the upper example send the following SMS from the host phone to the ZEUS4-VD:
;LN8=12;LN1=13;LN2=123;LN3=5;LN4=45;LN7=12;
If you want to get the confirmation SMS back then write “+” before SMS command:
;+LN8=12;LN1=13;LN2=123;LN3=5;LN4=45;LN7=12;
9.8 MAIN POWER LOST AND TELEPHONE NO. LINKING – LN5
Page 17
The ZEUS4-VD will send an SMS message in case when the main power has been lost. In this case
the ZEUS4-VD will send an SMS to user. The default SMS is “Main Power Lost”. You can also
program how many time the unit must be without power before sending this message. The default
time is 5 second (parameter MAIN).
Table of contents
Popular Security System manuals by other brands

Whelen Engineering Company
Whelen Engineering Company SS361 installation guide

Lince
Lince 1937-SAXA-L Installation, operation and maintenance manual

Optex Morse
Optex Morse MDC-16ET-32D user guide

Crow
Crow Shepherd installation manual

aJile Systems
aJile Systems aJ-Orion user manual

Eldes
Eldes ESIM364 user manual