Kamoer X4 User manual

Contents
Warranty ................................................................................................................................................1
Notice...................................................................................................................................................... 2
1. About.................................................................................................................................................. 3
1.1 Product Introduction............................................................................................................... 3
1.2 Unboxing.................................................................................................................................. 4
1.3 Structure................................................................................................................................... 4
1.4 Accessories.............................................................................................................................. 5
1.5 Related Product.......................................................................................................................7
1.6 Specification.............................................................................................................................8
2. How to Use........................................................................................................................................9
2.1 Download Software................................................................................................................ 9
2.2 Connection Settings............................................................................................................. 10
2.3 Software Interface................................................................................................................ 16
3. Maintenance...................................................................................................................................22
3.1 Chemical Compatibility........................................................................................................ 22
3.2 Storage................................................................................................................................... 22
4. Technical Support....................................................................................................................... 22

1
Warranty
We warrant your product against any defect in material and workmanship, under normal use.
In the event a product is found to be defective within the warranty period of one year, we will,
at our option, repair or replace the defective product. The warranty period starts at the day of
purchase. For warranty validation, a proof of purchase must be furnished.
The followings are excluded from the warranty:
1.Improper use of the device causing malfunction;
2.The device is repaired or modified by an unauthorized person;
3.Use of non-produced material by our company i.e. pump tube;
4.Damage by disaster;
5.Improper maintenance causing damage;
6.Use of reagent or sample causing corrosion;
7.Damage by accident or over load;
8.Consumables, such as silicone tube and fuse etc.
To obtain warranty support, you may contact our local technical support. Our technical
support will attempt to diagnose and correct the problem. If the problem cannot be rectified,
our technical support will ask you to return the product. You will be asked to furnish proof of
purchase to confirm that the product is still under warranty.
Kamoer is registered trademark of Kamoer Fluid Tech (Shanghai) Co.,Ltd. We
reserve the right to improve or alter appearance and technical specifications
without notice.

2
Notice
We have considered user safety in the design process. Please read this manual
carefully. Any improper operation may cause damage or danger.
1. Safety
The product belongs to Active Products. To avoid danger, you should
observe the following rules.
If you find any visible damage, please do not switch on;
Be sure not to add any acid, alkali, or volatile solvents;
Be sure not to use in humid environment, avoid damage by short circuit;
Temperature change or mechanical wear may increase the volume error.
2. Defect and anomalous situation
You must stop any operation immediately if the equipment is damaged. The
equipment may be damaged when the following situations occur:
1)There is visual damage.
2)The product suddenly does not work.
3)The product is located in an inappropriate position.

3
1.About
1.1 Product Introduction
X4 dosing pump is an intelligent pump which has a micro computer with four miniature
peristaltic pump head. It is mainly used for aquarium tank to add a variety of elements, such
as calcium, magnesium, kh improver, trace ealements, etc. Customs using this product can
not only reduce the work of manual adding but also avoid leakage increases, add the amount
of excessive or inadequate mistakes.
Features
Compact, elegant appearance;
Machine interface friendly, powerful;
Support for Windows PC, Android terminal via WIFI control titration pump, set the operating
parameters;
Third gear flow rate can be set;
Support scaling function;
Embedded real-time clock, support scheduled start;
One day titration times 1-24 times can be set to support the next day, every two days,
titration, supported by a few drops of a given week;
Support for external RS485 expansion;
With 4 level detection function;
Support temperature detection, and alarm thresholds.
Applications
Aquarium tank dosing;
Aquarium tank temperature monitoring;
Laboratory timing dosing liquid.
Other timing, dosing liquid applications.
1.2 Unboxing
● Before opening the box, check whether the package is damaged during transport.

4
● After opening the box, check the reference packing list, make sure that you have all parts
and there are no damages.
If you find any shortage or damage, please contact your retailer.
1.3 Structure
The placement should always be higher than the tank
Input tube should be as short as possible in order to avoid reflux, output tube should
be above the containe. Please check carefully after connecting you tubes, make sure they
are not backwards.

5
1.4 Accessories
1.4.1 Pumping heads (including tube)
Standard tubing is PharMed BPT which can continuous work for 2000 hours, it can meet
most occasions.
1.4.2 Connecting tube
PVC transparent tube, pump import and export connection tube.

6
1.4.3 Tube Bracket
1.4.4 Power Transformers
Support GB, European standard, American Standard, Australian Standard.
1.5 Related Product

7
Product ID
Order number
Description
X4
X4 host.4 KPP heads and supporting 12V
DC motor (2x4mm PharMed BPT
tube).Button control, wifi control.
Pharmed BPT Features:
• Low particulate spallation
• Autoclavable and sterilizable
• Temperature resistant from -60°F to 275°F
• Withstands repeated CIP and SIP cleaning and sterilization
• Meets USP Class VI and FDA criteria
1.6 Specification:
Model: X4
Power adapter parameters
Input: See Power Adapter tab

8
Output: DC12V 1000mA
Work environment
Working Temperature: 0 - 70 ℃
Humidity: 10% - 90% (non-condensing)
Storage environment
Storage temperature: -20 ℃- 85 ℃
Storage Humidity: 10% - 90% (non-condensing)
Dosing
Dosing Channel: 4
Dosing times: 24 times / day -- once / 7 days
Fluid volume: 1 ml - 1000 ml
Fluid volume accuracy: <± 2%
Pump tube life:> 2000 hours
Configuration
Pumping head: 4 KPP
Display: 132x32 dot matrix LCD screen
Backlight mode: Standby off automatically
Control Interface: WIFI interfaces, PC software settings, Android settings
Extended Interface: RS485
Liquid level detection: 4 liquid level sensor
Temperature detection: with a temperature sensor, with temperature alarm thresholds (alarm
values can be set)
Shape
Dimensions (length × width × height): 250 × 150 × 75
Weight (without power adapter): 900 g

9
2 How to use
2.1 Download Software
Scan QR code to download.

10
2.2 Connection Settings
1> Direct connection
Preparations
1, An iPhone and install the X4 control software;
2, X4 power on.
Step 1: Search the network: "KAMOER-X4-(The X4 SN No.)"

11
Step 2: Connect the network with the password: 12345678
Step 3: Open X4 software, Android software enter password: 345678;
Step 4: Login.
Tips:
1.If you cannot find the network "KAMOER-X4-(The X4 SN No.)", reset the wifi
on the X4
How to reset wifi:
Press ESC to the X4 starting screen,
press the "SET " button
select 4 "Options"
select "Reset WiFi"
Press set to select "Yes" (wait 3-5 seconds.)
Back to the starting interface and power reset.
2. If the phone says connect failed or network error when you login, set the
configuration to default and reconnect;
Steps:
Open login software
select "Network" on the software
Change the network to default: 10.10.100.254
select "Reconnect"
It will say “Connect successfully”
Press "Okay"
Enter password:345678 , click "login";

12
2>Auto connect
Note: Software requirements:
X4 IOS Version: 1.3 (or higher)
X4 firmware version: 1.1.1 (or higher)
Preparation:
1 Install the latest control software of X4 on the phone;
2 Phone connected to your home router;
Step 1: Take out the pump, power on, wait for X4 shows the main interface
Step 2: Press the "SET" button to enter the menu.
Step 3: Press "UP" key to select "Options" and press the "SET" key to enter the
options menu.
Step 4: Press the "UP" key to select "Auto Connect" and press the "SET" key to
enter the confirmation screen.
Step 5: Press the "UP" or "DOWN" button to select "Yes" and press the "SET"
button.
Step 6: Change to your mobile phone operation

13
Step 7:
Open X4 control app, click “More” , click "Auto connect."

14
Step 8:
1 In the password input box, enter the password of the family router;
2 Click the "Start" button to start “Auto connect”.

15
Step 9:
1 When “Auto connect” is complete, X4 pump will make a beep, the screen
returns to the main screen;
Note: If failed, power off the X4. Start again from the first step.
Step 10:
After your login, it will auto turn to the main control page.
Note: 1. You only need to set Auto Connect for once, it will save the settings and
you can login to X4 by your own wifi.
2. If you want to login by a computer, change the IP address of the software
to the same as the phone.

16
2.3 Software Interface
The initial interface (time / temperature interface)
Time: displays the current time and date;
Temperature alarm: select whether temperature alarm;
Unit: Celsius or Fahrenheit
Read settings: Read the last saved settings;
Save settings: Save the current settings;
Temperature trends: record the last 24 hours the temperature profile;

17
Automatic Interface
Channel On/Off: Channel switch can turn off / on the pump;
Operational Mode: "every day", "every other day", "every three days", "weekly" optional;
Pump Gears: Fast/Moderate/Slow
Start time: 00: 00-23: 59 Optional (Note: you can set the hours, minutes can not be set);
End Time: 00: 00-23: 59 Optional (Note: you can set the hours, minutes can not be set);
Dose Times: the number must be divisible by period;
Dose volume: total liquid per day;
Per dose: Equal the total amount divided by the number of dose times;
Read settings: Read the last saved settings;
Save settings: Save the current settings;

18
Manual interface
Pump1: Pump 1
Volume: Manually dosing the total amount (plus stops automatically after);
Start: Start / stop switch;
Pump2, Pump3, Pump4 are the same as Pump1;
Other manuals for X4
2
Table of contents
Other Kamoer Laboratory Equipment manuals
Popular Laboratory Equipment manuals by other brands

Metrohm
Metrohm 942 Extension Module Vario LQH manual

Endress+Hauser
Endress+Hauser Liquistation CSF48 operating instructions

Beckman Coulter
Beckman Coulter Avanti J-26S XPI Instructions for use

RIDGID
RIDGID RT-3 quick start guide

Fowler
Fowler Xtra-Value Series operating instructions

wtw
wtw BZG 30 instruction manual

Thermo Scientific
Thermo Scientific SPD131DDA instruction manual

Biotage
Biotage V-10 Touch Lifting Instructions

Thermo Scientific
Thermo Scientific Sorvall BP 8 instruction manual

MRC
MRC WBT-200 Operation manual

Thermo Scientific
Thermo Scientific TZ-32 Zonal Rotor instruction manual

Biosan
Biosan RCP-24 User instructions