Battery LED
Activity LED
Sensor
Pull tag to activate
Insert ID here
Sounder
Alarm LED
Know your KANE78
1
Hello KANE78 getting started
1 Know your KANE78
2 Use: Alarm levels, warning, bump test, general
maintenance & cleaning
3 Specication&DeclarationofConformity
4 KANE ASSET MANAGEMENT (KAM)
Description
The KANE78 is a personal CO alarm, once activated the unit will operate for up to 2 years
in normal operation
Use
2
Alarm Levels
In accordance with EH40/2005 (Fourth Edition 2020)
Alarm trigger point CO >20ppm
Replace iD SafeTM
iD SafeTM is active
Warning!
If CO levels in a room or space exceed 20ppm it is strongly recommended that any
appliancesareswitchedo&thatthespaceisevacuated&ventilatedbeforeanybody
returns to the area. If in any doubt seek expert advice
Bump Test
Users of portable gas detectors are recommended to conduct a “bump” check before
relying on the unit to verify an atmosphere is free from hazard
A “bump” test is a means of verifying that a detector is working within acceptable limits
bybrieyexposingtoaknowngasmixtureformulatedtochangetheoutputofallthe
sensorspresent.(Thisisdierentfromacalibrationwheretheinstrumentisalsoexposed
toaknowngasmixturebutisallowedtosettletoasteadygure&thereadingadjusted
to the stated gas concentration of the test gas)
General Maintenance
Keep your KANE78 dry, if it gets wet wipe dry immediately as liquids can degrade
electronic circuits
Whenever practical, keep the KANE78 away from dust & dirt
Although your KANE78 is built to withstand daily use, it can be damaged by impacts
Use reasonable caution when using & storing the KANE78
Cleaning
Periodically clean your KANE78 using a dry lint free cloth
DONOTuseabrasive,ammableliquids,cleaningsolvents,orstrongdetergentsasthey
maydamagethenish,impairsafety,oraectthereliabilityofthestructuralcomponents
Warranty
Manufacturer’s warranty 12 months
Audible alarm ≥ 75db
Alarm LED
Battery LED
Activity LED
Specication
3
Parameter Accuracy Range
Carbon Monoxide +/- 5ppm to 100ppm 0-300ppm
Dimensions (approx.)
Weight
93mm x 106mm x 23mm
51g
Ambient Operating
Range
0°-40°C
10% to 90% RH non-condensing
850 to 1100 mbar atmospheric pressure
Battery Life Up to 2 years in normal operation (or >2800 hours in alarm)
Directive Title
201430EU Electromagnetic Compatibility (EMC)
201165EU Restriction of the use of certain hazardous substances in
electrical and electronic equipment (RoHS)
EU Declaration of Conformity
This declaration of conformity is issued under the sole responsibility of the manufacturer:-
Kane International Ltd.
Kane House, 11 Bessemer Road, Welwyn Garden City, Hertfordshire. AL7 1GF, UK.
Tel: +44 1707 375550 Web: www.kane.co.uk
The KANE78 is in conformity with the relevant Union harmonization legislation below:
Thefollowingharmonisedstandardsandtechnicalspecicationshavebeenapplied:
Certication The KANE78 is tested to the following standards
EMC EN61326-1:2013
Safety EN61010-1:2010 + A1:2019
RoHS IEC62321-2:2013, IEC62321-1:2013, IEC62321-3-1:2013,
IEC62321-5:2013, IEC62321-4:2013, IEC62321-7-2:2017,
IEC62321-7-1:2015, IEC62321-6:2015
Signed for on behalf of:- Kane International Ltd.
11th August 2020
Paul Morrison
Engineering Manager