Alarm LED
More than
set value
Less than
set value
AB
GRN ON
GRN ON
ON
OFF
RED ON
RED ON
OFF
ON
Alarm
Measuring
value
Description of alarm output and LED lights
<table 1>
The diagram below shows a control panel on the top of the body
FLOW
VOLUME
paldra
SET
0
7.5
15
30
22.5
Cap Cap
FLOW VOLUME
Procedures
1. Take a cap out
2. Set a alarm value with a screw
3. Press a set button.
4.
LED light confirms the Deviation from set value.
1.Analog output
JPSL
JPSL
JPSL
Analog output
Analog output
RL
RL
0~10V
RL≧3kΩ
4~20mA
RL≦250Ω
Output signal
2.Alarm output
VDD
VDD
(Relay load)
Alarm
output
CM
VDD<40V、I<100mA
(E.g. VDD=24V、RL=5.1kΩ)
D
The diagram below shows how to put a load. There is no polar character within the range
in rating voltage or current.
RL
RL: Load resistance
I
!
【Flowratesetvaluediagram】
(VR1)
・No need to set anything when you
chose a analog output, Please do
not press or rotate anything.
・Do NOT use metallic screw driver to
rotate or press to set. Use a insulating
material, foe example a plastic screw
driver.
・Minimum setting values are:
5L=0.5L/min、10L=1.5L/min、30L=5L/min
Alarm settings
!
Use relay with internal diode or external diode(D) to prevent damaging Photo
MOS-FET from back electromotive force as above when you use relay load.
E.g. V03C(HITACHI)
Remove the caps and you will see the volume and set button.
*you can set a alarm only when you chose a alarm output..
1. Power on (DC 24V) then LED (red or green) will be on.
2. Rotate the arrow with a plastic screw, for example, and set
a alarm value.
3. Press SET to confirm the settings. Micro computer inside of
the flow meter memories' it. To change the value, rotate
the arrow and press SET again.
*Do not need to reset the value after powered off.
4. Alarm is signaled with LED (D1).
(D1)
FLOW
VOLUME
paldra
SET
(VR1)
Volumescale
( /min)
1
2
53
456
7
8
9
100
Note: There is only the
numbers from 0 to 10 on the
volume. Please set the value
referring to this diagram.
10
15 20
25
30
GND
GND
5
10
15 20
25
30
10
12
20
4
mA
0~10V
0
5
10
V
0~10V
0
2.5 5/min
510 /min
15 30 /min
2.5 5/min
510 /min
15 30 /min
4~20mA
How to put a load Output description
JPSL-30L
(VR1)
2
456
8
10
JPSL-10L
(VR1)
FLOW
VOLUME
0.5 1.5
2
1
2.5 3
4
5
JPSL-5L
E.g.JPSL-30L
JPSL-30L
JPSL-10LJPSL-5L
0 1 2 3 4 5 6 7 8 9 10
15
12
18
24
30
1
2
3
4
5
2.5
0
0.5
2
4
6
8
10
5
0
1.5
*<table 1> explains definition of alarm output and LED. While
ordering select only one output
【Power on】
This flow meter does not have a switch to power on.
Connect a red wire,+V and black wire,0V with 24V.
Then LED will be on.
Put quick fastener on the adapter until the adapters are locked between
the gap of the fastener. Make sure it is tightly locked.
And vice versa.
③
Connections
・Please beware of the direct load/pressure on the flow meter (PPS). It
could cause leaking or damages.
・Do NOT grab or press the cover very hard when you are connecting(plumbing)
!
Quick fastener
Quick fastener
●Please store our products under environments as follows.
・Where it is NOT exposed to rain or water.
・Where it is NOT exposed to direct sunshine.
・Where it is NOT exposed to dust.
・Where it is NO vibration or impact.
・Where it is static-free.
・Where ambient environment is controlled between 0-50 degree Celsius without
dewing and freezing.
*Please store our products as you received.
Storage
Warranty and disclaimer
About instructions manual
●We are not responsible regarding the accident that occurred from the incorrect
use of our products or possible lack of information in this document.
Sensor body
Adapter is Rc3/8 female. Keep the adapter hold and screw the fitting.
At the time of shipment adapters and quick fastener has enclosed separately.
①
※
②
When you install our product
between the hard plumbing,
use hose or flexible tube to
keep the center core
straight.
!
Spanner Pipe fitting
Plumbing adapter
Plumbing adapter
Body cover
Insert an adapter into a body. There is O ring, P14, around the adapter. Please
pay attention to attach properly with no any particle in between
O ring P14
Material: Fluoro rubber
Adapter size Rc3/8
Body
Material:PPS
・Warranty period of our product is one year from the received date of the product(s).
・If the claimed defect of specifications or materials in the period of the warranty
are verified with a document, we will replace free of the product(s). This warranty
covers only our products. This warranty does not cover direct or/and indirect
damages like lost, damages or injurers etc. caused by defected products.
・We supply a replacement on request. And an inspection of the equipment does not
disclose any defect causing by us, the replacement will be charged.
*The replacement is the same product as we sold but we would supply a different
product for certain reasons.
*It refers the case which we do not have any responsibility.
・In use out of non-compliance regarding this instruction manual.
・Negligence in use.
・Dissembling or conversion of our products.
●It is not allowed to reprint or reproduce a part or full instruction manual without
any prior permission by us.
●All the contents of instruction manual are correct at the date of publication and
are subjected to change without notice. Please save the latest issue of our products.
●The contents of the outline and specification of the flow sensor in this operating
manual has followed as per the standards. Care must be carried out properly while
using sensor with a proper lay-out and consideration against external condition.
●Please contact us if you acknowledge any mistakes or unlisted information in this
instruction manual.
*The design, dimensions and specifications of the product in the catalog were correct
at the date of publication and are subjected to change without notice.
・A straight pipe length needs min. 7D on upper stream and 5D on
down stream to keep the accuracy.
・Please do not do the plumbing (Put and orifice) sudden changes
in the size of piping upstream.
・Install valves, bifurcations, gages etc. on down stream.
D=adapter size, 5L: 4.1mm, 10L: 5.8mm, 30L: 10mm
Flow
alarm
value
Voltage
output
Current
output
Photo
MOS FET
output
Photo MOS FET
Internal
circuit
Set button(SET)
Alarm LED
FLOW
VOLUME
Set
button(SET)
*A internal circuit of alarm output
is MOS-FET. ON: conduction and OFF:
No conduction
Pointthearrowtowardsthesettingvalue
【Indicationofdivisions】
Enlarged view
*E.g.
J
PSL-30L Number 5 means 15L/min.