Supplementary control 9045.
A 3 Operation
When EWL products are operated for
the first time and for every operation
thereafter, it is essential to note the points
mentioned in the section «
A 1.3
Safety
measures
»
!
Put central extraction system into operation.
Switch on supplementary control at mains
switch @.
ithout external signal transmitter and
without external sealed keypad
(automatic mode)
When the dust-generating consumer is put
into operation, the suction path is opened.
When the consumer shuts down, the suction
path is closed after a set after-running time.
ith external signal transmitter and
without external sealed keypad
When the signal transmitter is actuated (e.g.
with the foot switch , the suction path is
opened. At the end of the actuation of the
signal transmitter (switch , the suction path
closes after expiry of an after-running time
set on the ABSORmatic plus. The switch-
on state of the dust-generating consumer
has no effect on the suction path.
ith external sealed keypad on the
workstation
” Automatic / Continous
Automatic mode: When the dust-gene-
rating consumer is put into operation,
the suction path is opened. When the
consumer shuts down, the suction path
is closed after a set after-running time.
Continuous operation: The suction
path is opened regardless of the dust-
generating consumer.
ith external sealed keypad and exter-
nal signal transmitter
” Signal transmitter / Continous
When the signal transmitter is actuated
(e.g. with the foot switch , the suction
path is opened. At the end of the
actuation of the signal transmitter
(switch , the suction path closes after
expiry of an after-running time set on
the ABSORmatic plus. The switch-on
state of the dust-generating consumer
has no effect on the suction path.
Continuous operation: The suction
path is opened regardless of the dust-
generating consumer and of the external
signal transmitter.