Kenwood FG-272 User manual

©PRINTED
INJ.N
FUNCTION
GENERATOR
FG-272
INSTRUCTION
MANUAL
KENWOOD
CORPORATION
KENWOOD

TABLE
OFCONTENTS
INTRODUCTION3
FEATURES
3
PRECAUTIONS
4
SPECIFICATIONS
5
OPERATOR'S
CONTROLSANDINSTRUCTIONS- 8
FrontPanel• 8
Rear
Panel13
MAINTENANCE••••• 14
A
productof
KENWOOD
CORPORATION
17-5,2-chome,Shibuya,Shibuya-ku,Tokyo150,Japan
2

INTRODUCTION
TheMODELFG-272Sweep/FunctionGeneratorprovides
functionsofa functiongenerator,pulsegenerator,and
sweeposcillator.
FEATURES
1.
Wide-banddesign: sevenrangescover
full
oscillation
frequency
from
0.2Hzto2 MHz
2.
Selectable
output
ofsinewaves,squarewaves,and
triangl
waves
through
one-touchoperation.
3.TTLsquarewave
output
connectorfacilitatesusing
TTL-level
output
squarewavesasthesignalsource
forexperimentofa
digital
circuit.
4.ThesymmetryFunctionvariessymmetryofsaw-tooth
wavesandpulsewaves.
Itcaninvertthewavepolarity.
5.Applyingvoltage
from
0 to+ 10VtotheVCFIN
connector
implem
ntsexternalsweepaswellas
output
frequencycontrol.
6.Thelinearsweepfunctionprovidessweepfrequency
controluptomax.100: 1,Sweepfrequencyisvariable
from
0.5Hz(2seconds)to50Hz(20milliseconds).
Sweepcontrolisimplementedbyapplyingsweepsignal
totheVCFconnector
from
anexternaldevice.
7.OCvoltage(0to± 10V)canbeoverlaidupon
output
waveform.
8.CombineduseoftheATT-20dBpushbuttonandthe
continuous
attenuator
providesmaximum
attenuation
over40dB.
9.A smalland
light-weight
case
with
convenientcarrying
handle,whichalso
serves
asa
tilting
stand.
3

PRECAUTIONS
1.
DonotusetheFG-272FunctionGeneratorunder3.DonotrepeatswitchingonandofftheGenerator,
thefollowingconditions:
-
Places
exposedtothedirectsunlight4,Followtheinstructionsinsection" MAINTENANCE
-Veryhotandhumidroomsifthesupplyvoltageistobechanged.
-Rooms
with
excessive
mechanicalvibrations
-Neardeviceswhichirradiatestrongmagnetic
forces
orpulsevoltage
2.
TheFG-272operatesimmediatelyafterturningon
power.
For
accuratemeasurement,however,waituntilit
warmsupsufficientlyafterpressingthePOWER
switch.
4

SPECIFICATIONS
<FREQUENCY
CHARACTERISTICS
>
GENERAL
OutputWaveformSinewave,squarewave,
trianglwave,pulsewave,
TTL-level
squarewave,&
rampwave
Oscillation
FrequencyRange•••0.2Hzto2 MHz
7ranges
(1/10/100/1
k/10k
/100k/1M)
Frequency
Accuracy± 5%of
full
scale
External
FrequencyControl(VCF)
InputVoltage• 0 to+10; frequency
increases
with
positive
voltage
Frequency
VariableRange•••100: 1 ormore
DC
Offset••••••••••± 10V (opencircuit)
±5V
(into
500)
continuous
variable
Polarity• • • Invertedornon-inverted
SINE
WAVE
DistortionRatio1%or
less
(10Hzto100kHz)
OutputFrequency
Response
•••
Within
± 1.0dBupto100
kHz
(into
10Oatmax.
outputlevel)
Output• Variable
SQUARE
WAVE
Symmetry••••••••±3%or
less
(at100Hz)
Rise/Fall
Time100nsor
less
(atmax.
outputlevel)
OutputVariable
TRIANGL
WAVE
Linearity1%or
less
(at100Hz)
OutputVariable
5

TTL
OUTPUT
Rise/Fall
Time25nsor
less
OutputTTLlevel
<SWEEP
CHARACTERISTICS
>
InternalSweepLinear
Sweep
Frequency• • • • • 0.5Hz(2sec)to50Hz(20
msec),
continuousVariable
Sweep
Width
1 : 1 to100: 1,peak-to-
peakvariableandcontinuous
variable
External
sweep• BymeansofVCFinput
(Input
impedance: 13kO)
<OUTPUT
CHARACTERISTICS>
OutputVoltage• 20Vppormore(opencircuit)
10Vppormore
(into
50O )
Attenuator•••••••• -20dBstep,andcontinuous
variable
Impedance50O±10%
<
POWER
SUPPLY
>
InputVoltage
100/120/220/240
VAC± 10%
(Max.250VAC)
Frequency
•••••••••
50/60
Hz
Power
Consumption• • • • Approx.20VA
<ENVIRONMENTALCONDITIONS>
Storage
Temperature• • • -20to60°C,70%or
less
OperatingTemperature• • 0 to40°C,80%or
less
With
Specifications• • • • 23±5°C,70%or
less
6

<SIZE
& WEIGHT>
Dimensions
(WHO)• 240x 64x 190mm
Weight1.8kg
<ACCESSORIES
>
Instruction
Manual•••••••1
AC
cable••••••••••••1
Fuse
(0.3AT)1
(0.2A)1
7

OPERATOR'S
CONTROLSANDINSTRUCTIONS
FRONTPANEL
Fig.
1
8

®POWERPushbutton
Pressing
thispushbuttonturnsonpower.LEDlights
uptoindicatepowerison*
(2)
RANGE(Hz)SelectorSwitchAssembly
Selects
thefollowingsevenrangesofoscillation
frequency:
XI:
0.2Hz to
2
Hz
X10:
2
Hz to 20Hz
X100: 20Hz to 200Hz
X1k: 0.2kHz to
2
kHz
X10k:
2
kHz to 20kHz
X100k: 20kHz to 200kHz
X
1
M : 0.2MHzto
2
MHz
(3)FUNCTIONSelectorSwitchAssembly
Selects
output
waveformoutofsinewave(^V),
trianglwave(/\,), andsquarewave(H—i)-
0ATT-20dBPushbutton
pressing
thispushbuttonattenuatesinputsignalby
20dB.
9

(DINVERTPushbutton-
Depressing
(buttonengaged)invertspolarity.Another
press
(buttonreleased)recoverstheformerpolarity.
Fig.
2 illustrateseffectsoftheINVERTpushbuttonwithrespecttoDUTYcontrolknobsetting.
Fig.
2 EffectofINVERTPushbuttonwithrespectto
DUTY
ControlKnobSetting
^\^^F>olarity Normal Inverted Normal Inverted
Waveforrr?\^/7
Counterclockwise
Rotation
Counterclockwise
Rotation
Clockwise
Rotation
Clockwise
Rotation
Square
Wave
TrianglWave
Sine
Wave
TTL
Wave
10

©MAIN/PULSEOUTPUT
Jack
MAIN
: Outputssinewave,trianglwave,orsquare
waveselected
with
theFUNCTTONswitch
assembly.
PULSE
: Outputspulsewave,regardlessof
FUNCTIONswitchsetting.
©AMPLITUDEControl
Rotatingthisknobvariesamplitudeofoutput
waveform.
(8)DC
OFFSET
Control
PullingthisknobadmixesDCvoltage
with
output
signal.
Clockwise
rotationadmixespositivevoltage.
Counterclockwise
rotationadmixesnegativevoltage.
Fig.
3 illustratesseveraltypesofwaveform
with
the
DCOFFSET
knobpulledand50-ohmloadconnected.
ZeroDCoffsetatmax.signallevel
Offset
limit
fornon-clippingsignal
Excessive
offset
Fig.3
ApplicationExampleofDCOffset
11
Positive
DCoffset NegativeDCoffset
Positive
DCoffset NegativeDCoffset

(9)DUTY/PULLTOWARS(SymmetryAdjustment)Control
Controls
symmetryofoutputsignal.
Pullingthisknob,andclockwiserotationvariesthe
dutyratio
from
1:1to5:1.
This
adjustmentmakespulsewaveofsquarewave,
rampwaveorsaw-
tooth
waveoftrianglewave,
andasymmetricsinewaveofsinewave.
Note
:
Note
that
controllingthisknobchanges
frequency.
©
SWEEP
RATE
Control
Controls
sweeprate(sweepfrequency)oftheinternal
sweep
oscillator.
©
SWEEP
WIDTH
Control
Rotatingtheknobcontrolssweepwidth.
©
FREQUENCY
ControlDial
Variablepotentiometervariesfrequencywithinthe
rangeselected
with
theRANGEselectorswitch
assembly
@.Thedialisscaled
from
0.2to2.0.
©
SWEEP
SelectorPushbutton
Depressing
(button
engaged)
selects
internalsweep.
Another
press
(button
released)
selects
external
sweep.
12

REAR
PANEL
©VCFInput
Jack
By
applyingvoltagetothisjackinthestatewhere
the
SWEEP
selectorpushbutton© isanother
press
(button
released),frequencyofoutputsignalcan
bevaried.
Applicationofvoltage
from
0 to10Vvaries
frequencyuptomax.100: 1.
©PowerConnector
Connector
forsupplyingACpower.
Use
thededicatedpowercord.
©
Fuse
Holder
Fuse
holderforACpowersupply.
13
Fig.
4

MAINTENANCE
1.
Fuse
Replacement
Ifthefusehasblownout,findoutandeliminatethe
cause.
Then,
replaceitwitha newfuse.Usea 0.3A slow-blowfuseforsupplyvoltageof100to120V,ora 0.2A fuse
forsupplyvoltageof220to240V.
Fuse
holderisprovidedontherearpaneloftheunit.
2.
ChangingSupplyVoltage
WARNING: Priortoopeningthe
case,
besuretodisconnectthepowercordfromthesocket.
2-1HowtoRemove
Case
To
openthe
case,
turntheunitupsidedown,andremovefour
screws
fromthe
case
baseplate.(SeeFig.5.)Then,
lift
thebaseplatetodetachit.
2-2HowtoChangeSupplyVoltage
The
FG-272isavailableforsupplyvoltageof100,120,220,and240VAC,50/60Hz.
To
changethesupplyvoltage,removethe
case
(inaccordancewithitem2-1above),andreconnectthevoltage
selector
plugontheprintedcircuitboardintheunittoa desiredvoltagepositiononthevoltageterminalboard.
(See
Fig.6.)
14

Screws
(4)
Fig.
6 Internal
Selection
of
Supply
Voltage
Rubbershoe
Fig.
5
Disassembly
and
Assembly
of
Case
Case
Fuse
side
Voltage
selector
plug
Voltageterminalboard
Rearside
Power
transformer
Frontside
15
Table of contents
Other Kenwood Portable Generator manuals
Popular Portable Generator manuals by other brands

Garland
Garland BOLT 325 QG instruction manual

Mosa
Mosa LIGHT & ENERGY TF IM5.5Y L-4X150 Use and maintenance manual

Westinghouse
Westinghouse iGen4500DF user manual

Buffalo Tools
Buffalo Tools GEN4000LP instruction manual

Kipor
Kipor IG3000 Operation manual

Porter-Cable
Porter-Cable H1000IS-W instruction manual