  9. Key 7 SA840-A30 User manual

Key 7 SA840-A30 User manual

sa840_a30_inst_eng_400.doc
All specifications are subject to change. For latest info check on www.keyseven.co .
Having problems? Contact your dealer or visit our
homepage www.keyseven.com.
Select output format
Output for at selection is done during power-up.
Connect wires a shown in below table, apply power, wait for buzzer acknowledge
and finish by disconnection power and the wires fro below table.
Wire connection for programming
For at
no.
Output for at
YELW  GREEN to  VIOLET to 
WHITE nothing nothing
1 ABA ( agstripe card)
Deafault selected
YELLOW

GREEN to

VIOLET to

nothing
WHITE
nothing
2 Wiegand
26-bit
YELLOW  GREEN to  VIOLET to 
nothing nothing WHITE
3 RS232, 9600,N,8,1
Log function
YELLOW

GREEN to

VIOLET to

PINK
nothing
nothing
4 MI Wiegand
(26/8-bit)
Like til Motorola/Indala
YELLOWl  GREEN to  VIOLET to 
PINK+WHT nothing nothing
5 UT
For use with Unitek, NOX Syst.
YELLOW

GREEN to

VIOL
ET to

PINK
WHITE
nothing
6 AVNG
For AlphaVisionNG/CP-508LCD
YELLOW  GREEN to  VIOLET to 
PINK nothing WHITE
7 ATS Wiegand
YELLOW

GREEN to

VIOLET to

nothing
PINK
nothing
8 COOPER
For RS central panels
YELLOW  GREEN to  VIOLET to 
WHITE PINK nothing
9 TAC Wiegand
For I/Net Seven
YELLOW

GREEN to

VIOLET to

nothing
WHITE
GREEN
10 Castle
(ver 4 eller nyere)
For CS2600/2700/2800
YELLOW  GREEN to  VIOLET to 
nothing PINK WHITE
11 TAC ABA
For til I/Net Seven
Progra ing sequence:
1. Select output for at and connect wires acordingly
2. If protocol 6 then the ta per circuit can be disabled connecting the
BROWN wire to ground now.
3. Connect power
4. Potocol 6/8/10 (Red LED flashes): Enter ID 1-8 or hold a rando
prox up to the reader and wait for nu ber of beeps according to ID
no. If this is not done then ID=1 (Cooper) or ID=8 (AVNG).
5. Await nu ber of beeps according to for at no.
6. Disconnet power and wires.
SA840-A30 is now progra et and ready for use. Progra ing is stored in
internal non-volatile e ory of SA840-A30. Fascility code, if needed, can be
changed by use of KeyLink+ TECH PC progra . If progra ing sequence needs
changede then first follow below procedure for
Factory reset
.
Factory reset
1. Disconnect power
2. Connect PINK wire to ground (BLACK)
3. Wait 5 seconds until red LED flashes
4. Disconnect the PINK wire within next 5 seconds
5. Disconnect power.
SA840 is now back in factory deafault state and a new protocol can be selected.
Mounting
SA840 ounts with only 2 screws on flat building surface
1
Mark the 4 drilling holes with the
drill guide and drill the holes
according to the wall aterial.
2
Fasten the nylon reflector.
3
Guide the cable trough the hole in
the wall and fasten screws loosely.
4
Connect
SA840 wires appropriate and test ta per circuit with function 42 (
Sabotage
test)
. Tighten screws.
5
Clean key surface. Re ove adhesive protection fro front cover foil and place it
carefully on the SA850.
SA 40 is delivered with 3 meters of flexible
14-core wire:
Red
8
-
24V DC
Back
Ground. 0V
Green/White
-
Green/Brown
-
Yellow
CLS (ABA), Data 0 (Wiegand)
(open collector output)
Green
CCLK (ABA), Data 1 (Wiegand)
(open collector output)
Violet
CDAT (ABA)
(open collector output)
Blue
Ta per loop, wire 1
Blue/Pink
Ta per loop, wire 2
Gray/Pink
RS485 data, A (RS485)
Grey
RS485 data, B (RS485), TX (RS232)
White
LED indput
Pink
Buzzer input
Brown
Synchronizing. Only if two SA840’s are placed closer than 50c to each other.
Technical specifications
Power supply 8V to 24V DC
Current consu ption
typical 80 A
Ta per loop
isolated, ax100 A, 25 oh , 50V
Output for ats
RS232 (9600,N,8,1) , RS485, Wiegand, ABA,
UT, AVNG, TAC
Wiegand facility code
Progra able, default 7
Network ID at delivery 1
Prox reading distance
up to 10 c .
Prox type
125kHz, auto-tuning, EM4102 co patible
Di ensions (H-W-D)
0.59in-1.93in-0.59in (150 -49 -15 )
Weight
10.2oz (286g)
Operating te peratures
-30°F to 150°F (-35°C to 65°C)
Operating hu idity
0%-99%
Wire
10’ (3 ), 14
-
lead
SA 40-A30
INSTALLATIONS MANUAL
Rev. 4.00
•KEYPAD / PROX COMBO
•MULTI PROTOKOL OUTPUT
•SUITS MOST CONTROL PANELS
•ALSO FOR OUTDOOR USE
•SKAFOR approved in class 3
This manual applies for serial no. greater than 1xx20000
SA 40-A30 e ulates ABA ag. reader, Wiegand reader, RS232 and RS485
SA 40-A30 has a progra able facility code for Wiegand interface
SA 40-A30 interfaces directly to Alphatronics, Cooper, Castle and others
SA 40-A30 is a olded weatherproof construction for outdoor use
SA 40-A30 has an optical ta per security circuit
SA 40-A30 LED’s and buzzer can be externally controlled
SA 40-A30 has electrical isolated output for ta per/sabotage
SA 40-A30 can be connected directly to PC or printer
SA 40-A30 can be part of a SA850-series network
SA 40-A30 uses standard 125KHz EM4100-based prox cords / tags
SA 40-A30 is SKAFOR approved in class 3 (AIA 212.069)
DRILL GUIDE
5
7
5
5
Drill guide

Popular Security System manuals by other brands

BeaconMedaes MedPlus TotalAlert Operation and maintenance

BeaconMedaes

BeaconMedaes MedPlus TotalAlert Operation and maintenance

Exposure Olas Core Troubleshooting

Exposure

Exposure Olas Core Troubleshooting

ADEMCO Vista-10 installation instructions

ADEMCO

ADEMCO Vista-10 installation instructions

DUOTEC CO2 ALERT Mk X quick guide

DUOTEC

DUOTEC CO2 ALERT Mk X quick guide

First Alert HD6135FB user manual

First Alert

First Alert HD6135FB user manual

Bresser 33-10001 instruction manual

Bresser

Bresser 33-10001 instruction manual

Yale SmartHome Alarm series user manual

Yale

Yale SmartHome Alarm series user manual

LifeCall 7000 user guide

LifeCall

LifeCall 7000 user guide

X10 IN42A Setup instructions

X10

X10 IN42A Setup instructions

DEXAPLAN TM 605 Operating and safety instructions

DEXAPLAN

DEXAPLAN TM 605 Operating and safety instructions

Bosch ND 200 LSN installation manual

Bosch

Bosch ND 200 LSN installation manual

E2S D105AX instruction manual

E2S

E2S D105AX instruction manual

DSC PC4020 -  2 instruction manual

DSC

DSC PC4020 - 2 instruction manual

Visonic POWERMAXCOMPLETE PANEL - Installer's guide

Visonic

Visonic POWERMAXCOMPLETE PANEL - Installer's guide

Atlantic'S MD-204R user manual

Atlantic'S

Atlantic'S MD-204R user manual

First Alert FA 270 instruction manual

First Alert

First Alert FA 270 instruction manual

Labkotec idOil-30 3G Installation and operating instructions

Labkotec

Labkotec idOil-30 3G Installation and operating instructions

Hills VSD1 installation guide

Hills

Hills VSD1 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.