Kidde SLICK KN-RTH-RF User manual

1
Kidde Safety Europe, Mathisen Way, Colnbrook, SL3 0HB, UK.
www.kiddefyrnetics.co.uk
© Kidde Fyrnetics 2010
®
1209-7202-00
1
KN-RTH-RF Wireless Remote
For use with RF-SFTP 230V Mains Operated Wireless Base
Thank you for purchasing a Kidde Fyrnetics alarm accessory.
Please read through our guide in full. Important information
included and the manual must be left with the householder.
Wireless Base Remote Test and Hush
Introduction
The Remote Test and Hush (RTH) unit is designed to linked with
one of the wireless alarm bases in your alarm system.
To test the alarm, simply press the test button on the RTH unit.
The alarm linked to this RTH accessory will sound an alarm first
followed by the remaining interconnected units.
To hush an alarm event, simply press the hush button on the
remote test and hush unit. The alarm linked to this RTH accesso-
ry will silence or all but the initiating alarms will silence
Accessory – Remote Test and Hush. ( RTH )
21008428 REV. A
1209-7202-00(21008428)_V5_a1:_ 2011.1.10 4:50 PM Page 1

This accessory is battery powered, designed to operate reliably for
ten years under normal use conditions. There are no user
serviceable or replaceable parts which includes the fitted battery
• The RTH is equipped with two non-latching buttons, one for
Hush and other for test.
• This unit transmits upon pressing either the test or hush button
however it has an in-built safety delay time of 4 seconds where
the unit will not transmit after a button has been released
• This unit has a in-built maximum continuous transmit time of
36 seconds as a safety feature if either button is continuously
pressed
To avoid excessive operational drain on the battery avoid situa-
tions where the button(s) are pressed and held depressed (such as
by objects left on the device). This will seriously reduce the serv-
ice life of the battery.
2
1209-7202-00(21008428)_V5_a1:_ 2011.1.10 4:50 PM Page 2

Connecting the Remote Test and Hush Accessory
The accessory works with one Wireless Alarm base. We recommend
you enrol it with the alarm in your main living room.
• Press the enrol button on the RF wireless base.
˚Wireless base should already be enrolled into a system. If
the RTH is to be used with a wireless base not in a system
of wireless bases, the wireless base should be set as a
master unit before enrolling the RTH. See installers guide
for wireless base.
• Press any button on the RTH.
• Verify the amber LED on the alarm has changed from 2 seconds
on 2 seconds off to rapid blinking.
• Press the enrol button on the base to complete the process.
Operation
The accessory is designed to sit on a table top or fit into a bracket
on the wall.
During normal operation the RTH can be used to test the smoke
alarms in your system by transmitting a signal to the RF wireless
base it has been enrolled with. The smoke alarm will then perform a
test as if the button on the alarm had been pressed and held. The
alarm will then produce an alarm pattern and all other alarms that
are interconnected (both by wires and RF) will produce an alarm
pattern to verify the units and the system are functioning properly.
During a non-emergency alarm event, the hush button can be
pressed to temporarily silence the alarms. If the smoke alarm that
has detected the abnormal level of smoke is connected to the RF
wireless base the RTH is enrolled to, pressing the hush button will
silence all the alarms in the system. If another alarm has detected
the smoke, all the units but the one(s) that initiated the alarm will
silence, allowing the occupant or emergency service personnel
more time to quickly identify the initiating alarm.
FUNCTION BUTTON ENROL BUTTON
ALARM RELEASE
LATCH
AMBER LED
ERROR INDICATOR
CEILING
ALARM
GREEN LED
POWER/TRANSMIT IND.
3
Figure 1 Wireless Base and Alarm
1209-7202-00(21008428)_V5_a1:_ 2011.1.10 4:50 PM Page 3

4
When operating on battery backup power, the RF wireless base
only listens for transmissions every 10 seconds, therefore you
may have to press and hold the button on the RTH for up to 10
seconds or until the alarm can respond.
Technical Specification
Power: Lithium battery with 10 year
life*
Temperature (operating): 0 – 40°C
Humidity: 0-95% (non-condensing)
Radio Frequency: 868MHz
Wireless range: Up to 10 metres.
Mechanical: 89mm x 89mm 34mm
120g
Approvals (Independently tested to comply with):
EMC Directive 89/336/EEC
R&TTE Directive 99/5/EC
ETSI EN 301 489-1 V1.8.1
(2008-04)
ETSI EN 301 489-3 V1.4.1
(2002-08)
ETSI EN 300 220-1 V2.3.1
(2009-04)
ETSI EN 300 220-2 V2.3.1
(2006-04)
EN 55022: 2006
EN 61000-3-2: 2006
EN 61000-3-3: 2005
* 10 year life is based on normal operation and will be reduced
if stored at elevated temperatures or button is pressed for extend-
ed periods of time.
Disposal
ENVIRONMENTAL PROTECTION
Waste electrical products should not be disposed of with house-
hold waste. Please recycle where facilities exist. Check with
Local Authority or Installer for recycling advice.
1209-7202-00(21008428)_V5_a1:_ 2011.1.10 4:50 PM Page 4

5
Guarantee
Kidde Fyrnetics guarantees to you as a purchaser that the enclosed
accessory will be free of defects in material, workmanship or
design under normal use and service for a period of five (5) years,
from the date of purchase.
The Guarantee is not assignable. Our liability to you, under this
guarantee is limited to repairing or replacing any part which we
find to be defective in material, workmanship or design, free of
charge to the customer, who is situated within the UK, upon send-
ing the base with proof of date of purchase, postage prepaid, to
Kidde Safety Europe, Mathisen Way, Colnbrook, SL3 0HB, UK.
The terms of this guarantee will not apply in the following circum-
stances: If unit has been damaged, modified, neglected, dismantled,
contaminated, abused or altered after the date of purchase, or if it
fails to operate due to incorrect selection, sitting, installation, main-
tenance, or damage caused by failure to abide by the instructions
supplied.
The liability of Kidde Fyrnetics, arising from the sale of this wire-
less accessory or under the terms of this guarantee shall not in any
case exceed the cost of replacement of the device, in no case, shall
be liable for consequential loss or damaged resulting from the fail-
ure of the device or for the breach of this or any other guarantee,
express or implied, or for damages caused by failure to abide by
the instructions supplied. This guarantee does not affect your statu-
tory rights.
1209-7202-00(21008428)_V5_a1:_ 2011.1.10 4:50 PM Page 5
Table of contents