6.1 Learn to inter-connect
! Secure all the alarms that need to be interconnected to the mounting plate
and twist clockwise.
! Take one as master, press the LEARN button to green (the signal indicator
switch from red/green/none color).
! Take the second one as slave, press the LEARN button to red, then press
the TEST button of master one 1-2 seconds, the LED of the master start
flashing and then stop, meanwhile the slave one will receive the signal and
the red LED start flashing and later stop, which means these two
pieces have been inter-connected successfully.
NOTE: if you have some more pieces to be inter-connected into the same
system,repeat the last operation and connect them with the master one,
press LEARN button of the master into none color after all devices are
connected.
6.2 Test operation:
Press the TEST button of master and do not release (around 10 seconds)
until the slaves receive the signal and alarm together, the test operation has
been completed. When Press the TEST button of slave, the master will
receive the signal and alarm too.Then learning of interconnection is completed.
6.3 Delete memory:
Press the learn button to green state in some seconds, the LED
starts flashing means the memory is deleted.
Note1: All the smoke alarms of this model have wireless interconnection
function. It requires at least two smoke alarms. Within effective interlink
range, you can interconnect as many units as you want. We suggest you
learn the interconnection operation before you install the product to the
ceiling, to make your operation more efficient.
Note2: The interlink range of this product is
≥
100m (open field). But as