INSTALLATION
• Connect the lead from the antenna to the input of the SA124F.
• The outputs are then cabled to 1 or more TV points/wall outlets (maximum 4).
• Connect the power injector to one of the TV points/wall outlets.You should then see the LED is
active on the SA124F, indicating the device is on.
See image below for connecting power injector to wall plate.
PSK06
14 VOLTDC
TV SET
PLUG INTO
WALL PLATE IF REQUIRED
ADAPTOR
2M CABLE
CONNECT TO POWER POINT
A division of GME Pty Ltd.
AUS: 1300 463 463. NZ: (09) 274 0955.
P/N: 572459
SPECIFICATIONS
Parameters Specifications
Frequency Range 174 - 694 MHz
Output Figure 105dB DIN45004B @
(-60 dB IMR)
Input/Outputs 1 x Input / 4 x Outputs
Input/Outputs Return Loss <-10dB
Gain 12dB per port
ESD Protection ±6kV
Supply Voltage 12V to 18V DC
Powering Option Remotely via PSK06
Dimensions in mm 88(W) x 72(H) x 16(D)
Weight 87g