KITA KFP02A Series User manual

INSTRUCTION MANUAL
DIGITAL FLOW AND PRESSURE SENSOR
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
KFP02A Series

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-1-
Product Safety InstructionsProduct Safety Instructions
■This section indicate the levels of risks with the labels of Danger, Warning and Caution.
Danger Danger indicates high level of risk, will lead to fatal or serious injuries if
not avoided.
Warning Warning indicates medium level of risk, it might cause death or serious injuries.
Caution Caution indicates low level of risk, it might result in minor injuries, such as scald,
electric shock, etc. and the product, equipment and machines might be damaged.
Warning
■ Precautions for usePrecautions for use
➀Operated within the specified voltage.Operated within the specified voltage.
Malfunction or damaged product, electric shock or fire may
be resulted by exceeding the specified voltage range.
➁Do not exceed the maximum load current.Do not exceed the maximum load current.
It may damage the product.
➂Do not use any load that generates surges.Do not use any load that generates surges.
Surge protection is present but applying surge voltage
repeatedly will ultimately damage the product.
When using with inductive load (such as relay or solenoid),
please install a flyback diode across the load (polarity must
be observed).
➃Observed the internal voltage drop.Observed the internal voltage drop.
When used at a specified voltage, if the sensor is functional
but the load does not work, please check if the operating
voltage of the load meets the following formula.
➄Do not operate the product outside the specifications.Do not operate the product outside the specifications.
The sensor will be damaged by exceeding the flow rate and
working pressure.
➅Do not use flammable fluids and/or permeable fluids.Do not use flammable fluids and/or permeable fluids.
They may cause fire, explosion or corrosion.
■ Working fluid and working environmentWorking fluid and working environment
Power supply –
voltage
Internal voltage >
drop of sensor
Minimum operating
voltage of load
Do not use in an explosive gas atmosphere.Do not use in an explosive gas atmosphere.
The sensor does not have explosion-proof structure, fire,
explosion or corrosion can result.
Do not use near a surge voltage generated area.Do not use near a surge voltage generated area.
Solenoid lifters, high frequency induction furnaces and
motors, etc. can generate high surge voltages, if using near
the sensor will cause the internal circuit components to
deteriorate and cause damages.
Sensors can not withstand lightning strikes.Sensors can not withstand lightning strikes.
The product is CE compliant, but can not resist surge voltage
of lightning strikes, take measures to avoid lightening strikes
in the system.
Do not use in an environment where sensors could beDo not use in an environment where sensors could be
splashed by water or oil.splashed by water or oil.
Enclosure rating is IP40, please avoid water or oil splashed
environment to prevent adversely effects.
Do not use in an environment subject to largeDo not use in an environment subject to large
temperature cycling.temperature cycling.
Internal components of the sensor will be affected adversely
by large heating/cooling cycles other than ordinary changes
in temperature.
Do not mount the product in locations where it isDo not mount the product in locations where it is
exposed to radiant heat.exposed to radiant heat.
This could result in damage and/or malfunction.
➁
➂
➃
➄
➅
➀

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-2-
Warning
Caution
■ Wiring PrecautionsWiring Precautions
■ Installation PrecautionsInstallation Precautions
■ Installation PrecautionsInstallation Precautions
■ Maintenance PrecautionsMaintenance Precautions
■ DisposalDisposal
■ Other PrecautionsOther Precautions
Check wire color and terminal number when wiring.Check wire color and terminal number when wiring.
Incorrect wiring can cause permanent damages to the
sensor, check wire color and terminal number against the
manual before wiring.
Avoid repeatedly bending or stretching the lead wire.Avoid repeatedly bending or stretching the lead wire.
It can cause damage to the sheath, or breakage of the wire.
Confirm wiring insulationConfirm wiring insulation
Please avoid poor insulations (and interference from another
circuit, poor insulation between terminals, etc.) it can lead to
over current being applied to the product, causing damage.
Do not route wires and cables together with power orDo not route wires and cables together with power or
high voltage cables.high voltage cables.
The product may malfunction due to interference or noise
and surge voltage from power and high voltage cables.
Do not short-circuit the load.Do not short-circuit the load.
When the load is short-circuited, an error will be displayed.
But excess current may cause damage to the sensor.
Do not connect wire when the power is on.Do not connect wire when the power is on.
It may cause damages to the sensors/equipment/machines.
RS485 products must be connected theRS485 products must be connected the
communication wire first.communication wire first.
Wiring for RS485 MODBUS : Please connect RS485 (B+) or
(A-) before connecting power supply to avoid short circuit to
damage to product.
Please follow the specified tightening torque.Please follow the specified tightening torque.
Over tighten will damage the product.
Do not mount the sensor in a place that will be usedDo not mount the sensor in a place that will be used
as a foothold.as a foothold.
The product may damage if sit or step on it accidentally.
While installing the KFP02A to the pipe, please applyWhile installing the KFP02A to the pipe, please apply
I.D. 9 mm or more air tube.I.D. 9 mm or more air tube.
Ensure the flow direction of the fluid.Ensure the flow direction of the fluid.
Please follow the flow direction indicator for installation and
piping.
Flush out all dirt and dust by air blow before connectFlush out all dirt and dust by air blow before connect
the piping to the sensor.the piping to the sensor.
Do not drop or hit.Do not drop or hit.
When installation, do not drop, hit or apply excessive shock
(100m/s2). Internal damage can cause malfunction even if
the housing appears to be undamaged.
Do not install multiple products in close proximity.Do not install multiple products in close proximity.
The heat generated from each product could cause the
temperature to rise and change the characteristics of product
or deterioration of the plastic parts. Please set the products
10mm apart from each other.
Hold the sensor body when installing.Hold the sensor body when installing.
The tensile strength of the cable is 24.5 N and apply
excessive pulling force can cause damage to the sensor.
Do not insert a stick or wire into the piping ports.Do not insert a stick or wire into the piping ports.
Do not touch the terminals or connectors when powerDo not touch the terminals or connectors when power
is on.is on.
Sensors at end-of-life must be disposed of inSensors at end-of-life must be disposed of in
accordance with E-Waste regulations of the country/accordance with E-Waste regulations of the country/
region, NOT disposed of with regular garbage.region, NOT disposed of with regular garbage.
After power is supplied, the output will remain off untilAfter power is supplied, the output will remain off until
the display is turned on. Please operate the sensorthe display is turned on. Please operate the sensor
after the value is shown.after the value is shown.
Stop the control systems before perform settingStop the control systems before perform setting
changes.changes.
During the initial flow and pressure setting, the product will
switch the output according to the existing settings until the
changes are complete.
➁
➂
➃
➄
➅
➀
➆
➁
➂
➃
➄
➀
➀
➁
➀
➁
➂
➀
➁
➀

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-3-
Disclaimer
➀
➂
➁
Our warranty applies solely to our product, not to any other damages and injuries which occur by earthquakes, fires,Our warranty applies solely to our product, not to any other damages and injuries which occur by earthquakes, fires,
the acts by third party, other matters, acts intentionally, acts accidentally, misuse, or other abnormal conditions thatthe acts by third party, other matters, acts intentionally, acts accidentally, misuse, or other abnormal conditions that
are not the responsible of KITA.are not the responsible of KITA.
Our warranty applies solely to our product, not to any other additional damages (the loses of business profits,Our warranty applies solely to our product, not to any other additional damages (the loses of business profits,
business interruption, etc.) incurred due to using or misusing the product.business interruption, etc.) incurred due to using or misusing the product.
Our warranty excludes any injuries and damages happened by using the product beyond the specified range ofOur warranty excludes any injuries and damages happened by using the product beyond the specified range of
catalog or/and not following the instruction manual.catalog or/and not following the instruction manual.
Warning
■ FluidFluid
Check the regulator and flow adjustment valve before introducing the fluid.Check the regulator and flow adjustment valve before introducing the fluid.
If the pressure or flow rate exceeded the specified range, the sensing element may be damaged.
The sensing element cannot measure properly if foreign matter adheres to it.The sensing element cannot measure properly if foreign matter adheres to it.
On the inlet side, be sure to install an air filter below the filtration level of 10um.On the inlet side, be sure to install an air filter below the filtration level of 10um.
Recommended Equipments and InstallationRecommended Equipments and Installation
※NOTENOTE ※
Please install a throttle valve on the outlet side of the sensor to prevent errors caused by unstable flow.
Inlet Outlet
Flow Sensor
Pressure Sensor
KFP02A Series
Air Source Air Dryer Filter Regulator Micro Mist Separator
(Oil Mist Filiter)
➁
➂
➃
➀
Throttle Valve

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-4-
Contents
Installation Instructions 5
1.1 Piping ........................................................................................................ 5
1.2 Mounting bracket .................................................................................... 6
1.3 Wiring ........................................................................................................ 7
1.3.1 NPN output, Analog output and external input ............................ 7
1.3.2 PNP output, Analog output and external input ............................ 8
1.3.3 NPN output, RS-485 Modbus ....................................................... 9
1.3.4 PNP output, RS-485 Modbus ........................................................ 9
How to Use 10
2.1 Names and Functions of Individual Parts ...................................... 10
2.2 Functions Instructions ........................................................................ 11
2.3 Operation Setting ................................................................................. 13
Modbus RTU Instruction 49
Error Code Instruction 51
Specifications 52
Pressure Loss Characteristics 53
Thermal Mass Principles of Flow Sensor
53
Ordering Information 54
Dimensions 55
Internal Structure 57
1
2
3
4
5
6
7
8
9
10

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-5-
Install the pipe by following the
arrow indication that shows the
air flow direction on the product.
Use straight piping 8cm or longer
(I.D. 9 mm or more) to connect the
Piping Port (Inlet side). If straight
piping is not installed, the accuracy
may vary by ± 2% F.S..
Avoid sudden changes in the piping
size on the inlet side of the product.
Do not release the outlet side
piping port of the product directly to
the atmosphere without the piping
connected.
※ Straight Piping: The pipe is without
bending and the cross sectional areas of
the pipe keeps the same.
Using on other parts of the product with a wrench
may damage the product.
When piping with metallic area, please refer to the
applicable torque below.
Over torquing may be damaged the product.
When insufficient torque, the connection may loosen
to cause air leakage.
After installation completed, please make gas and
power on and operate properly and test leakage to
verify the installation correct.
Installation
1InstallationInstallation
1.1 Piping
Flow
direction
Piping Port
(Inlet side)
straight piping 8cm
or longer
(I.D. 9 mm or more)
Piping Port
(Outlet side)
Caution
Piping Specification Required Torque
Rc1/2", G1/2"
28 ~ 30 N.m
Rc3/4", G3/4"

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-6-
1.2 Mounting Bracket / Optional Parts
The LCD display may be difficult to see at certain angles.
The sensor can be installed horizontally or vertically, but the flow rates may
change because of the installation way of the product or piping.
The tightening torque for screws should be under 0.3 ±0.1 N.m.
Installation
Mounting screw
M3 x 0.5P x 5L
Mounting screw

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-7-
1.3 Wiring Diagrams
1.3.1 NPN Output, Analog Output and External Input
Installation
● NPN Output / Analog Voltage Output / External Input
● NPN Output / Analog Current Output / External Input
Main CircuitMain Circuit
1
2
3
4
5
6
Brown (Power supply +)
Brown (Power supply +)
Blue (Power supply –)
Blue (Power supply –)
Black (Output 1)
Black (Output 1)
White (Output 2)
White (Output 2)
Yellow (External input)
Yellow
(External input)
1kΩOrange
(Analog output)
Orange
(Analog output)
1
2
3
4
5
6
Load
Load
Load
Load
Load
Brown
Orange
Yellow
Black
White
Blue
Pin No. Line color Content
1 Brown Power supply (DC 12 to 24V DC)
4 Black Output 1 (Max. load current:125mA)
5 White Output 2 (Max. load current:125mA)
3 Yellow External input
2 Orange Analog voltage output:1 ~ 5V
Analog current output:4 ~ 20mA
6 Blue 0V (GND)
1
2
3
4
5
6

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-8-
1.3.2 PNP Output, Analog Output and External Input
Installation
● PNP Output / Analog Voltage Output / External Input
● PNP Output / Analog Current Output / External Input
1
2
3
4
5
6
Brown (Power supply +)
Brown (Power supply +)
Blue (Power supply –)
Blue (Power supply –)
Black (Output 1)
White (Output 2)
Black (Output 1)
White (Output 2)
Yellow (External input)
Yellow
(External input)
Orange
(Analog output)
Orange
(Analog output)
1
2
3
4
5
6
1kΩ
Main CircuitMain Circuit
Load
Load
Load
Load
Load
Brown
Orange
Yellow
Black
White
Blue
Pin No. Line color Content
1 Brown Power supply (DC 12 to 24V DC)
4 Black Output 1 (Max. load current:125mA)
5 White Output 2 (Max. load current:125mA)
3 Yellow External input
2 Orange Analog voltage output:1 ~ 5V
Analog current output:4 ~ 20mA
6 Blue 0V (GND)
1
2
3
4
5
6

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-9-
1.3.3 NPN Output, RS-485 Modbus
1.3.4 PNP Output, RS-485 Modbus
Main Circuit
Brown (Power supply +)
Blue (Power supply –)
Black (Output 1)
White (Output 2)
Yellow
RS-485 (A-)
Orange
RS-485 (B+)
1
2
3
4
5
6
Load
Load
1
2
3
4
5
6
Brown (Power supply +)
Blue (Power supply –)
Black (Output 1)
White (Output 2)
Yellow
RS-485 (A-)
Orange
RS-485 (B+)
Main Circuit
Load
Load
Brown
Orange
Yellow
Black
White
Blue
Pin No. Line color Content
1 Brown Power supply (DC 12 to 24V DC)
4 Black Output 1 (Max. load current:125mA)
5 White Output 2 (Max. load current:125mA)
3 Yellow RS-485 (A-)
2 Orange RS-485 (B+)
6 Blue 0V (GND)
1
2
3
4
5
6
Installation

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-10 -
2How to UseHow to Use
2.1 Names and Functions of Individual Parts
How to Use
Setting Button
Use for selection each mode
and set value confirmation.
▼Button
▲Button
Use for mode selection,
ON/OFF switching and
set value adjustment.
Use for mode selection,
ON/OFF switching and
set value adjustment.
Lead Wire
Connector
Piping Port (Inlet side)
Piping Port
(Outlet side)
LCD Display
Body
Connector
Output 1 Indicator
3 Color LCD Display Flow Symbol
Flow Display
Button
Button
Analog Signal Indicator
Output 2 Indicator
Output 1 Indicator
Output 2 Indicator
Analog Signal Indicator
Pressure Symbol
Pressure Display
Setting Button
Pressure Unit
Display Section
Flow Unit
Display Section
Ag OUT1OUT2 Ag OUT1OUT2
kgf/cm2bar psi kPa Pulse ft3/min mL3/min

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-11-
● Function Setting Mode
Function
Code Item Default setting Explanation Page
[F-01]
[oUt1] OUT1 setting
Select Output 1 corresponding
to flow sensor or pressure
sensor.
Set the flow rate or pressure
value to switch ON/OFF.
P.14
[oUt1] OUT1 sensor correspondence FLo
[FLo ] OUT1 output mode HYS
[oUt1] OUT1 output type no
[Fl-1] OUT1 set value input
50% of maximum measured flow rate
501 : 250 L/min
102 : 500 L/min
202 : 1000 L/min
[FH-1] OUT1 set value input
60% of maximum measured flow rate
501 : 300 L/min
102 : 600 L/min
202 : 1200 L/min
[F-02]
[oUt2] OUT2 setting
Select Output 2 corresponding
to flow sensor or pressure
sensor.
Set the flow rate or pressure
value to switch ON/OFF.
P.19
[oUt2] OUT2 sensor correspondence FLo
[FLo ] OUT2 output mode HYS
[oUt2] OUT2 output type no
[Fl-2] OUT2 set value input
50% of maximum measured flow rate
501 : 250 L/min
102 : 500 L/min
202 : 1000 L/min
[FH-2] OUT2 set value input
60% of maximum measured flow rate
501 : 300 L/min
102 : 600 L/min
202 : 1200 L/min
[F-03]
[CLor] LCD Display setting
Select back light color and
display mode. P.20
[disp] LCD Display corresponding
to output oUt1
[ CoL] LCD Display color setting SoG
[F-04]
[rESP] Flow/Pressure sensor
selection FLo Select the response time for
switch output.
Pressure sensor: 2.5ms ~ 1500ms
Flow sensor: 50ms ~ 1500ms
P.21
[FLo ] Response time setting 800(ms)
[F-05]
[UPdA] Flow/Pressure sensor
setting FLo Display refresh cycle can be
set in 200ms, 500ms or 1000ms. P.23
[UPdA] Display refresh time of flow
sensor setting 500(ms)
[F-06]
[Unit] Unit setting
Select the UNIT of pressure /
flow sensor. P.25
[FLo ] Flow unit setting LPn
[PrES] Pressure unit setting PA
[F-07][rEFE] Flow reference standard
setting Anr
Select the flow value is shown
under standard (ANR) or normal
condition (NOR).
P.26
[F-08][ AnG] Analog output setting FLo Select the analog corresponding
to pressure or flow sensor. P.27
How to Use
2.2 Function Instruction

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-12-
● Measurement Mode
Function
Code Item Default setting Explanation Page
[F-09][EEPr] Accumulated value hold setting oFF To save the last accumulated flow value
every 2 or 5 minutes. P.28
[F-10] [diS]
Flow sensor display mode setting
Select to display Instantaneous Flow or
Accumulated Flow Mode.P.29
[ dsP]
Flow sensor display mode setting
inS
[F-80][ SYn]Sync the value of flow analog
output and display oFF Turn ON to synchronize the value of
flow analog output and display. P.30
[F-90]
[AoUt] Analog output range setting oFF
Select analog output corresponding to
flow sensor or pressure sensor. P.31
[AG L] Min. value of the settable range 0
[AG H] Max. value of the settable range
Pressure sensor :
1000 kPa
Flow sensor : Max.
measured flow rate
[F-91][ Eco] Power-Save mode setting no Select if turn on power-save mode to
reduce power consumption P.35
[F-92] [inP] External input setting r r Select for Accumulated flow rate zero
clear, Auto-Shift or Auto-Shift zero. P.36
[F-93]
[nbUS] Modbus RTU setting
Set ID number, baud rate and
transmission format. P.37
[ id] ID number setting 1
[ rAT] Baud rate setting 96(9600 Bd)
[ For] Transmission format setting n81
[ trA] Communications protocol setting rTU
[F-94][FinE] Fine adjustment Setting oFF The displayed value can be adjusted
slightly. P.39
[F-95]
[FoUt] Forced output function
To force output ON/OFF to test the
switch function. P.41
[oUT1] Forced output function oFF
[oUT2] Forced output function oFF
[F-99] [rEsT] Reset to the default setting Return to the factory default setting. P.42
[ rsT] Reset to the default setting oFF
Item Explanation
Pressure display Display pressure value.
Flow display Display instantaneous flow rate.
Accumulated flow rate display Display accumulated flow rate.
Pressure zero setting The displayed pressure value can be adjusted to "0".
Instantaneous Flow rate zero setting
The displayed instantaneous flow rate value can be adjusted to "0".
Accumulated flow rate zero clear The accumulated flow rate can be set to "0".
Peak value display
The maximum pressure or instantaneous flow can be detected when the power is supplied for a period.
Bottom value display
The minimum pressure or instantaneous flow can be detected when the power is supplied for a period.
Key lock/unlock mode To prevent errors occurring due to unintentional changes of the set values.
How to Use

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-13-
Function Selection Mode
At Measurement Mode, press button for more than 3 sec. to display
[F-01]. Press or button to select other setting functions.
Press for 3 sec. at Function Setting Mode to return to Measurement
Mode.
2.3 Operation Instructions
How to Use
Measurement Mode
Press button for
more than 3 sec.
Press button
Function Selection Mode
Enter in each function setting
kPa /minL
Ag
kPa /minL
Ag
kPa kPa/min /minL L
Ag Ag

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-14-
Press button (to be continued)
Setting corresponding sensor and operating mode of OUT1.
● 1. Flow sensor setting1. Flow sensor setting
Press or button at Function Selection Mode to display [F-01] [oUt1].
How to Use
2.3.1 [F-01] OUT1 Setting
Press button
Press button
Output Mode Setting
Select output mode :Select output mode :
Press or button to select output
mode of OUT1.
4 output modes included.
Hysteresis Mode
※ NOTE : Accumulated Pulse Mode is available in OUT1, but not in OUT 2.
Window Comparator Mode Accumulated Output Mode Accumulated Pulse
Output Mode
Sensor Selection
Selected
Output
Set Value
Press or button to select flow
sensor of OUT1.
Flow sensor Pressure sensor
kPa /minL
Ag
kPa kPa/min /minL L
Ag Ag
Selected
Sensor
Set Value
kPa /minL
Ag
kPa /minL
Ag
kPa /minL
Ag
kPa /minL
Ag
kPa /minL
Ag

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-15-
How to Use
Press button
Press button
Press button to return to
Function Selection Mode
Set Value Setting
Fixed Hysteresis Setting
OUT1 set value setting :OUT1 set value setting :
Fixed hysteresis setting :Fixed hysteresis setting :
Press or button to adjust the set
value.
Press or button to adjust fixed
hysteresis value.
Hysteresis Mode [HYS] : [FL-1],[FH-1]
Window Comparator Mode : [FL-1],[FH-1]
Accumlated Output Mode [ADD] : [AdL1],[AdH1]
※ NOTE :
Set value setting will not display when Accumulated Pulse Output is set.
※ NOTE : Fixed hysteresis setting is available when selecting Window Comparator Mode.
Output Type Setting
Selected
Output
Set Value
Press or button to select OUT1
type.
NO mode NC mode
kPa /minL
Ag
kPa /minL
Ag
OUT1 type setting :OUT1 type setting :
kPa /minL
Ag
Selected
Mode
Selected
Mode
Set Value
Set Value
kPa
kPa
/min
/min
L
L
Ag
Ag
Fixed Hysteresis
Mode
Set Value
kPa /minL
Ag
※ NOTE : Type setting will not display when Accumulated Pulse Output Mode is set.
kPa /minL
Ag

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-16-
How to Use
Press button (to be continued)
● 2. Pressure sensor setting2. Pressure sensor setting
Press or button at Function Selection Mode to display [F-01] [oUt1].
Press button
Press button
Output Mode Setting
Select output mode :Select output mode :
Press or button to select output
mode of OUT1.
Hysteresis Mode Window Comparator Mode One Point Set Mode
Sensor Selection
Selected
Output
Set Value
Press or button to select
pressure sensor of OUT1.
Flow sensor Pressure sensor
kPa /minL
Ag
kPa kPa/min /minL L
Ag Ag
Set Value Sensor
kPa /minL
Ag
kPa /minL
Ag
kPa /minL
Ag
kPa /minL
Ag

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-17-
How to Use
Press button
Press button
Press button to return to
Function Selection Mode
Set Value Setting
Fixed Hysteresis Setting
OUT1 set value setting :OUT1 set value setting :
Fixed hysteresis setting :Fixed hysteresis setting :
Press or button to adjust the set
value.
Press or button to adjust fixed
hysteresis value.
Hysteresis Mode [HYS] : [L-1],[H-1]
Window Comparator Mode : [L-1],[H-1]
One Point Set Mode [oPS] : [P-1]
※ NOTE : Fixed hysteresis setting will not display when Hysteresis Mode is set.
Output Type Setting
Set Value Output
Press or button to select OUT1
type.
NO mode NC mode
kPa /minL
Ag
kPa /minL
Ag
OUT1 type setting :OUT1 type setting :
kPa /minL
Ag
Set Value
Set Value
Mode
Mode
kPa
kPa
/min
/min
L
L
Ag
Ag
Fixed Hysteresis
Mode
Set Value
kPa /minL
Ag
kPa /minL
Ag

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-18-
How to Use
OFF
ON
Flow / Pressure
Hysteresis Mode
Hysteresis Mode
FL-1
(FL-2)
L-1(L-2)
FH-1
(FH-2)
H-1(H-2)
OFF
ON
0 L
Time
AdH1
AdL1
AdH2
AdL2
Normal Open Mode
Normal Close Mode
OFF
ON
P-1
(P-2)
Time
Pressure
Flow
Window Comparator Mode
One Point Set Mode
Accumulated Output Mode
Accumulated Pulse Output Mode
Flow / Pressure
Accumulated Output Mode
Flow
One Point Set Mode
Pressure
Window Comparator Mode
Flow / Pressure
Flow / Pressure
OFF
ON
FL-1
(FL-2)
L-1(L-2)
FH-1
(FH-2)
H-1(H-2)
FL-1
(FL-2)
L-1(L-2)
FH-1
(FH-2)
H-1(H-2)
OFF
ON
FL-1
(FL-2)
L-1(L-2)
FH-1
(FH-2)
H-1(H-2)
OFF
ON
OFF
ON
P-1
(P-2)
OFF
ON
0 L
AdH1
AdL1
AdH2
AdL2
【NOTE:】
*1. In case hysteresis is set at less than or equal to 2 digits, switch output may chatter if input detected fluctuates near the set point.
*2. When using window comparator mode, the difference between two set points must be greater than the fixed hysteresis, otherwise
will cause the switch output to malfunction.
OFF
ON
Time
50ms
Flow Range 500L
5L
1000L 2000L
10L 10L
Pulse Output Rate

KFP02A Series Instruction Manual
@2022 KITA Sensor Tech. Co., LTD. URL http://www.kita.com.tw
-19-
2.3.2 [F-02] OUT2 Setting
Setting corresponding sensor and operating mode of OUT2.
1. Press or button at Function Selection Mode to start "OUT 2 Setting"
[F-02] [oUt2].
2. Check the [F-01] for the same follow setting.
NOTE : The OUT2 Setting dose not have Accumulated Pulse Output Mode.
Table of contents
Popular Security Sensor manuals by other brands

Mustang Survival
Mustang Survival MD0450 22 owner's manual

US Netting
US Netting Defender Gate 20 instruction manual

Emos
Emos G1190 manual

Tractel
Tractel stopfor K Operating and maintenance instructions

Grasslin
Grasslin talis PS 360-7-1 operating manual

Radionics
Radionics TriTech D8535 installation instructions

GE
GE Interlogix AP100PI installation manual

Curbell
Curbell CSM-BC500 Quick setup guide

PCB Piezotronics
PCB Piezotronics 8120-400A Installation and operating manual

Draminski
Draminski Pregnancy Detector for Dogs Operation manual

Navim Group Company
Navim Group Company EsiWelma Sensigas URS20SS quick start guide

2gig Technologies
2gig Technologies Alarm.com ADC-IS-100-GC installation guide