Profort KM-1714 User manual

www.profort.com ver. 4.02
infraSpot
Infra-red detector
Function:
infraSpot is a wireless detector, which contains an active infra-red sensor. The sensor measures the
distance to the enclosed object and if this distance is changed, an alarm is activated.
The detector register a malfunction, if the detector is being exposed to too much light or is too close to
the painting. If the amount of light is changed suddenly, an alarm is activated. The objective of the infra-
red sensitive sensors are placed on the detector’s front.
Note: the damage of the lens may destroy the functions of the detector.
The unit is supplied with an internal battery.
Assembly:
infraSpot must be placed as high as possible. Preferably so that the antenna is placed either in the right
or left corner of the object, which it is placed on. Note that the end of the antenna must not be hidden
behind metal or reinforced concrete. This considerably limits the reach of the antenna.
The detector is installed by means of Double-sided tape or through the hole, so that the infra-red sensor
points at the object, which is to be monitored.
Service and maintenance:
Every 6 month a check must be made whether or not the detector can be activated. This can be done
either by increasing or decreasing the distance between object and detector. Then it must be checked
whether an alarm has been registered from the detector on the central unit. If the detector doesn’t work
the battery is exchanged. If it still doesn’t work, the entire detector is exchanged.
The detector’s battery is exchanged by loosening the screw at the back of the detector. The plug to the
battery is loosened carefully by using a small screwdriver. Hereafter the new battery is put in. Note that
the battery must be placed so that it is not squeezed when the cover is installed.
It may be necessary to clean the
objective of the infra-red sensitive
sensor. This is done by using a soft
dry cloth.
Build-in temperature and humidity sensor:
The infraSpot has a build-in temperature and humidity sensor. Every 4 minute the infraSpot sends the
actual temperature and humidity, and these data can be logged in the central unit.
Please notice that the sensors are placed inside the detector and therefore react slowly on changes in the
climate conditions.
The sensors have the tolerances shown in the figure below:
Specifications:
Dimensions: 79 x 39 x 9 mm
Weight incl. internal battery: 25 g
Radius of wireless signal
of 868MHz: Up to 1000m by exterior measurement
Detection distance from
Infra-red sensor: Up to 40 mm
Power supply: Battery
Battery life span: Up to 3 years
Temperature: Minus 10°to plus 55°Celsius
www.profort.com ver. 4.02
Installation:
Mouting:
The infraSpot is mounted via. double sided tape or using the build-in hole making sure that the ir-sensor
is pointing directly towards the object.
Do not place the infraSpot, buzzer quite close at the object! The signal strength of the sounder will be
affected. Keep at distance of e.g. 1mm.
The best RF-signal:
The infraSpot must be placed if possible in the middle between the object and the wall. Note that the
end of the antenna must not be hidden behind metal or reinforced concrete. This considerably limits the
reach of the antenna.
Positioning:
The infraSpot uses an active reflective ir sensor. Therefore the infraSpot sends out ir light towards the
object and measure the amount of ir reflection coming back. If the amount of ir light changes an alarm
will be send. If the distance to the object is too big an installation error will be send to the central.
Therefore three things are important concerning positioning the infraSpot:
1. The distance between the infraSpot and the object must be as short as possible. Preferable
quite close in order for the sensor to get as much ir-light back as possible.
2. The surface the infraSpot reflects must be as bright as possible. Preferable quite white. If the
surface is dark place white tape or paper on the object. White surface reflect more ir-light than
dark surface.
3. The infraSpot must be placed in darkness in order to avoid ’false’ light from lamp or daylight.
’False’ light will make the sensor believe a change in distance to the object has happened.
Too large distance: Acceptable distance:
÷√
Too dark surface: Good bright surface:
÷√
Too much ‘false’ light: Acceptable darkness:
÷√

Other Profort Security Sensor manuals

Profort infraSpot User manual

Profort

Profort infraSpot User manual

Profort PirSpot User manual

Profort

Profort PirSpot User manual

Profort luxSpot User manual

Profort

Profort luxSpot User manual

Profort ultraSpot User manual

Profort

Profort ultraSpot User manual

Profort vibraSpot User manual

Profort

Profort vibraSpot User manual

Profort climaSpot User manual

Profort

Profort climaSpot User manual

Profort combiSpot User manual

Profort

Profort combiSpot User manual

Profort infraSpot User manual

Profort

Profort infraSpot User manual

Profort inSpot User manual

Profort

Profort inSpot User manual

Popular Security Sensor manuals by other brands

EPE Conseil CEMPROTEC 34 user guide

EPE Conseil

EPE Conseil CEMPROTEC 34 user guide

Master cool 55500 instruction manual

Master cool

Master cool 55500 instruction manual

Paradox SR250 quick start guide

Paradox

Paradox SR250 quick start guide

HIK VISION DS-PDMCS-EG2-WB quick start guide

HIK VISION

HIK VISION DS-PDMCS-EG2-WB quick start guide

X-Vision HD 960H user manual

X-Vision

X-Vision HD 960H user manual

Unit UT12 Series user manual

Unit

Unit UT12 Series user manual

C.P. Electronics MWS1A-C-PRM-LV installation guide

C.P. Electronics

C.P. Electronics MWS1A-C-PRM-LV installation guide

Rf-t Safe Place Mother Transmitter user guide

Rf-t

Rf-t Safe Place Mother Transmitter user guide

HIK VISION DS-PDPC12PF-EG2-WB manual

HIK VISION

HIK VISION DS-PDPC12PF-EG2-WB manual

C.P. Electronics GEFL-PB-ABS installation guide

C.P. Electronics

C.P. Electronics GEFL-PB-ABS installation guide

Guard master CU3 installation instructions

Guard master

Guard master CU3 installation instructions

Tinker & Rasor AP instructions

Tinker & Rasor

Tinker & Rasor AP instructions

Delta SATEL AQUA-PET-2E user manual

Delta

Delta SATEL AQUA-PET-2E user manual

Cooper & Hunter SPHNS-01E instruction manual

Cooper & Hunter

Cooper & Hunter SPHNS-01E instruction manual

Elmo IRB60F2 Technical manual

Elmo

Elmo IRB60F2 Technical manual

C.P. Electronics VITMR-MWS6-PRM Product guide

C.P. Electronics

C.P. Electronics VITMR-MWS6-PRM Product guide

Paradox Paradome DG467 instructions

Paradox

Paradox Paradome DG467 instructions

C.P. Electronics MWS6-PRM-2CH installation guide

C.P. Electronics

C.P. Electronics MWS6-PRM-2CH installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.