• TRUERMS
• BACKLITDISPLAY
• BARGRAPH
• LEADSTORAGE
• MAX/MIN
• 3-5/6DIGIT
6000COUNTLCD
• AUTO/MANUAL
RANGE
• AUTOHOLD
HOLD
Apo
AUTO
RANGE
TRMS
A-HOLD
SYMBOLSUSEDONLCD
~
ACMeasurement DCMeasurement
-
NegativeDCValue
AT
AutoRangeActive
O
.L.
Overload:RangeExceeded Apo
AutoPower-OffActive
LowBattery
HOLD
HoldActive
MIN
MinimumReading
M
AX
MaximumReading
%
DutyCycleMode FrequencyMode
V
VoltageMeasurement
A
CurrentinAmps
Ω
ResistanceinOhms DiodeTest
F
CapacitanceinFarads ContinuityTest
Relative/ZeroMode
n
Nano10
-9
µ
Micro10
-6
m
Milli10
-3
k
Kilo10
3
M
Mega10
6
°F
DegreesFahrenheit
°C
DegreesCelsius
A- HOLD
Auto-HoldActive
LOW
Z
LowImpedance
ELECTRICALSPECIFICATIONS
DCVoltageMeasurement
Range Resolution Accuracy
600mV ˜ 600V 0.1mV ˜ 0.1V ± (0.2% + 5 digits)
1000V 1V ± (0.5% + 10 digits)
OverloadProtection: 1000V InputImpedance(Nominal): >10MΩ, <100pF
InputImpedance(LOWZ): >3kΩ, <200pF, up to 600V RMS
ACVoltageMeasurement
Range Resolution Accuracy
40Hz ~ 400Hz
Accuracy
400Hz ~ 2kHz
600mV 0.1mV
± (0.75% + 5 digits)
± (2.5% +10 digits)
6V ~ 600V 1mV ~ 0.1V ± (2.0% + 8 digits)
1000V 1V ± (0.75% + 8 digits) ± (2.0% +8 digits)*
Continued on next page.
OverloadProtection: 1000V RMS InputImpedance(Nominal):>10MΩ, <100pF
InputImpedance(LOWZ): >3kΩ, <200pF, up to 600V RMS
FrequencyResponse: 40 to 2kHz Response: True RMS
*Accuracy for 400Hz ~ 1kHz range only.
DCCurrentMeasurement
Range Resolution Accuracy
600µA ~ 400mA 0.1µA ~ 0.1mA ± (1.0% + 5 digits)
6A ~ 10A 1mA ~ 10mA ± (1.5% + 5 digits)
OverloadProtection:µAmA:400mA (F440mA/1000V fuse) /AInput:10A(F11A/1000V fuse)
ACCurrentMeasurement
Range Resolution Accuracy
40Hz ~ 2kHz
600µA ~ 400mA 0.1µA ~ 0.1mA ± (1.2% + 5 digits)
6A ~ 10A 1mA ~ 10mA ± (1.8% + 5 digits)
OverloadProtection:µAmA:400mA (F440mA/1000V fuse) /AInput:10A(F11A/1000V fuse)
Frequency: 40 to 2kHz Response: True RMS
ResistanceMeasurement
Range Resolution Accuracy
600Ω˜6MΩ0.1Ω˜0.001MΩ± (1.0% + 5 digits)
50MΩ0.01MΩ± (1.5% + 10 digits)
OverloadProtection: 600V RMS
CapacitanceMeasurement
Range Resolution Accuracy
60nF 0.01nF
± (3.5% + 6 digits)
600nF ~ 6000µF 0.1nF ~ 1µF
OverloadProtection:600V RMS
FrequencyMeasurement
Range Resolution Accuracy
99.99Hz ˜399.9kHz 0.01Hz ˜0.1kHz ± (0.1% + 3 digits)
OverloadProtection: 600V RMS Sensitivity: 2.5V RMS
DutyCycleMeasurement
Range Resolution Accuracy
1.0 ˜99.0% 0.1% ± (0.2% per kHz + 0.1% + 8 digits)
OverloadProtection: 600V RMS Sensitivity: < 50V RMS
FrequencyRange: 0.5Hz to 10kHz
DiodeTest
OverloadProtection Range TestCurrent OpenCircuitVoltage
600V RMS 6.0V DC 0.25mA <1.8V DC
ContinuityTest
OverloadProtection OpenCircuitVoltage Threshold(Appx.)
600V RMS <0.44V <40Ω
TemperatureMeasurement
Range Resolution Accuracy
-58 ~ 600°F 0.1°F ± (1.0% + 5.4°F)
-50 ~ 600°C 0.1°C ± (1.0% + 3.0°C)
600 ~ 1832°F 1°F ± (1.0% + 5.4°F)
600 ~ 1000°C 1°C ± (1.0% + 3.0°C)
OverloadProtection: 600V RMS K-typeThermocoupleAccuracy: Not specified
Specifications subject to change.

WARRANTY
See www.kleintools.com, contact Klein Tools at 1-877-775-5346, or visit a
distributor for warranty information.
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period
of time. Do not expose to high temperatures or humidity. After a period of
storage in extreme conditions exceeding the limits mentioned in the General
Specifications section, allow the instrument to return to normal operating
conditions before using it.
DISPOSAL/RECYCLE
Caution:This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.
CUSTOMERSERVICE
 DONOTapplyvoltagetothermocouple.
• Fahrenheit range: -58° to 1832°F (Celsius range: -50° to 1000° C).
8. Temperature:
Features:
MAX/MIN RELHOLD
TestingFuse:
• When selecting uA or mA/A functions the meter will indicate
“LEAd” if the test leads are not properly connected to the meter.
• Note: This message remaining on the screen after properly
connecting the test leads is an indication that the fuse is open.
KLEINTOOLS,INC.
450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
www.kleintools.com
Rev A 1/13 139750
7. Frequency(Hz)/DutyCycle:<400kHz
Features:
HOLD
6. LowImpedance(LOWZ):<600V
 DONOTuse(LOWZ)modeatvoltagesgreaterthan600V.
• Press SELECT to choose AC or DC Voltage.
• Use Low Impedance (LOW Z) mode to reduce ghost voltages.
• See AC/DC Voltage instruction.
Capacitance Features:
HOLD
 Safelydischargecapacitorbefore
measurement.
• Reading may take up to 60 seconds
for large capacitors.
AUTOHOLD
4007036
ENGLISH
FEATUREDETAILS
MM6000
InstructionManual
GENERALSPECIFICATIONS
The Klein Tools MM6000 is a True RMS, auto-ranging multimeter.
It measures AC/DC voltage, low impedance voltage, AC/DC current,
resistance, capacitance, frequency, duty cycle, and temperature. It can also
test diodes and continuity.
• OperatingAltitude:6562 ft / 2000 m
• RelativeHumidity:<75%
• OperatingTemperature:O°C/32°F to 45°C/113°F
• StorageTemperature:-20°C/ -4°F to 60°C/140°F <80% R.H.
• AccuracyTemperature:18°C/64°F to 28°C/82°F
• TemperatureCoefcient: 0.1*(specified accuracy)/ °C
• SamplingFrequency:3 samples per second
• Dimensions: 7” x 3.5” x 1.875”
• Weight:14 oz.
• BatteryLife:160 Hours
• Calibration:Accurate for one year
• Accuracy:± (% of reading + # of least significant digits)
• CATRating:CAT III 1000V, CAT IV 600V
• Certications:Conforms to UL Stds 61010-1 & 61010-2-030.
Certified to CAN/CSA C22.2 No.61010-1, 61010-2-030,
IEC 61010-2-030:2010 MOD, ANSI/ISA-61010-2-030 (82.02.03).
• PolutionDegree:2
• CountryofOrigin:USA (of US and imported parts)
WARNINGS
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Before each use, verify meter operation by measuring a known
voltage or current.
• Never use the meter on a circuit with voltages that exceed the
category based rating of this meter.
• Do not use the meter during electrical storms or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Ensure meter leads are fully seated, and keep fingers away from the
metal probe contacts when making measurements.
• Do not open the meter to replace batteries or fuses while the probes
are connected.
• Use caution when working with voltages above 60V DC or 25V AC
RMS. Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock, replace
batteries if a low battery indicator appears.
• Unless measuring voltage or current, shut off and lock out power
before measuring resistance or capacitance.
• Always adhere to local and national safety codes. Use individual
protective equipment to prevent shock and arc blast injury where
hazardous live conductors are exposed.
SYMBOLS
~
ACAlternatingCurrent WarningorCaution
DCDirectCurrent DangerousLevels
DC/ACVoltageorCurrent DoubleInsulatedClassII
Ground ACSource
C
E
A
G
F
D
H
J
I
M
L
K
N
B
5
1
8
3
4
6
7
2
1. ACVoltage:<1000V.(LOWZ)<600V
Features:
MAX/MINRANGEHOLDREL
 DONOTattempttomeasuremorethan1000V.
 DONOTuse(LOWZ)modeatvoltagesgreaterthan600V.
• Use Low Impedance (LOW Z) mode to reduce ghost voltages.
• Rotate selector to "AC" Voltage position.
• Attach RED lead to “V” input, BLACK lead to COM.
2. DCVoltage:<1000V.(LOWZ)<600V
Features:
MAX/MINRANGEHOLDREL
4. AC/DCCurrent(small):<400mA(For<400mAusemAµAinput)
Features:
 DONOTattempttomeasuremorethan400mA.
• Attach RED lead to “µA” input, BLACK lead to COM.
• Break circuit and connect meter in series (AS ABOVE).
• Select AC or DC current source.
5. Resistance/Diode/Continuity/Capacitance
Continuity Features:
MAX/MINHOLD
• Display shows resistance.
• Buzzer sounds if less than 40Ω.
Diode Features:
MAX/MINHOLD
Display shows:
• Forward voltage drop if forward biased.
• “O.L” if reverse biased.
AUTOHOLD
AUTOHOLD
AUTOHOLD MAX/MINRANGEHOLDREL
Resistance Features:
•
DONOT measure resistance on a live
circuit.
• Ω= < 50MΩ.
AUTOHOLDHOLDREL
RANGE MAX/MIN
 DONOTattempttomeasuremorethan10A.
• Start with this setting if current level is unknown.
• Break circuit to be measured.
• Attach RED lead to "A" input, BLACK lead to COM.
• Connect RED lead to one side of break and BLACK lead to the
other (meter in series).
• Meter will automatically select "A" when RED lead is connected to
"A" input. “LEAd” will show if connected but fuse is blown.
3. AC/DCCurrent(large):<10A
Features:
MAX/MINRANGEHOLDREL
 DONOTattempttomeasuremorethan1000V.
 DONOTuse(LOWZ)modeatvoltagesgreaterthan600V.
• Use Low Impedance (LOW Z) mode to reduce ghost voltages.
• Rotate selector to "DC" Voltage position.
• Attach RED lead to “V” input, BLACK lead to COM.
AUTOHOLD
A. DONOTattempttomeasuremorethan1000V.
B. DONOTattempttomeasuremorethan600Von(LOWZ)setting.
C. DONOTattempttomeasuremorethan400mA.
D. DONOTattempttomeasuremorethan10A.
E. AutoPower-Off(Apo)
• Device will power off after 30 minutes non-use.
• Press the select button to wake.
• Disabled during Max/Min function.
• Holding Select button while turning on disables Auto Power-Off.
F. SelectFunctionalityButton
• Switch between AC and DC.
• Switch between “Ω”, “ ”, “ ”, and “ ”.
• Switch between Hz and %.
• Switch between °F and °C.
• Wake meter during Auto Power Off.
G. RelativeReadingMode
• Press to store current value.
• Display shows the difference between the stored and live readings.
• Press again to return to live reading.
H. Auto/ManualRange
• Press repeatedly to cycle through manual ranges.
• Press for 2 seconds to return to auto ranging mode.
• AT is displayed on LCD only during auto ranging mode.
I. Max/MinHold
• Press to enter Max/Min mode; the largest and smallest values will be
saved while in this mode.
• Press repeatedly to alternate between the maximum and minimum
readings.
• Press for 2 seconds to return to live reading and clear the stored
maximum and minimum values.
J. Hold/AutoHold/Backlight
• Hold captures the current displayed value.
• Auto Hold captures the first stable displayed value, until a new stable
value is measured. The meter will then capture the new value and emit
a beep (V, Ohm, Temperature and Amp functions).
• Press to hold current input on the display.
• Press again to enter Auto-Hold to capture stable values.
• Press again to return to normal operation.
• Press and hold to activate display backlight.
• Using lights drains the battery significantly.
K.L. Battery/FuseReplacement
• When indicator is displayed on the LCD, batteries must be
replaced.
• Remove rubber boot, back screw and replace 2 x AAA batteries.
• This meter uses 440mA/1000V (69192) and 11A/1000V (69191)
fast blow fuses.
M. MagneticHangerAccessory(optional, sold separately)(69190)
• Slide magnetic adapter into protective rubber boot.
• Attach instruments to metal for hands-free use.
N. BarGraph
• The bar graph shows an approximate analog representation
of a measurement.
• The bar graph responds much faster than the digital display.
• The scale of the bar graph is zero to the maximum reading of
the selected range.
FUNCTIONINSTRUCTIONS
4007036

Other Klein Tools Measuring Instrument manuals

Klein Tools CL700 User manual

Klein Tools

Klein Tools CL700 User manual

Klein Tools RT390 User manual

Klein Tools

Klein Tools RT390 User manual

Klein Tools CL2500 User manual

Klein Tools

Klein Tools CL2500 User manual

Klein Tools CL380 User manual

Klein Tools

Klein Tools CL380 User manual

Klein Tools 501-915 User manual

Klein Tools

Klein Tools 501-915 User manual

Klein Tools CL3200 User manual

Klein Tools

Klein Tools CL3200 User manual

Klein Tools CL800 User manual

Klein Tools

Klein Tools CL800 User manual

Klein Tools 93MCLG User manual

Klein Tools

Klein Tools 93MCLG User manual

Klein Tools ET130 User manual

Klein Tools

Klein Tools ET130 User manual

Klein Tools CL360 User manual

Klein Tools

Klein Tools CL360 User manual

Klein Tools ET110 User manual

Klein Tools

Klein Tools ET110 User manual

Klein Tools CL320 User manual

Klein Tools

Klein Tools CL320 User manual

Klein Tools CL390 User manual

Klein Tools

Klein Tools CL390 User manual

Klein Tools ET200 User manual

Klein Tools

Klein Tools ET200 User manual

Klein Tools CL150 User manual

Klein Tools

Klein Tools CL150 User manual

Klein Tools ET110 User manual

Klein Tools

Klein Tools ET110 User manual

Klein Tools ET50 User manual

Klein Tools

Klein Tools ET50 User manual

Klein Tools CL800E User manual

Klein Tools

Klein Tools CL800E User manual

Klein Tools CL450 User manual

Klein Tools

Klein Tools CL450 User manual

Klein Tools CL360 User manual

Klein Tools

Klein Tools CL360 User manual

Klein Tools CL900 User manual

Klein Tools

Klein Tools CL900 User manual

Klein Tools CL2200 User manual

Klein Tools

Klein Tools CL2200 User manual

Klein Tools ET920 User manual

Klein Tools

Klein Tools ET920 User manual

Klein Tools MM500 User manual

Klein Tools

Klein Tools MM500 User manual

Popular Measuring Instrument manuals by other brands

Hach NITRATAX plus sc user manual

Hach

Hach NITRATAX plus sc user manual

TE Connectivity Integra INT-2270 Technical instructions

TE Connectivity

TE Connectivity Integra INT-2270 Technical instructions

SBS SBS-3510 Instruction Manual and Safety Information

SBS

SBS SBS-3510 Instruction Manual and Safety Information

Endress+Hauser Proline Promag L 400 operating instructions

Endress+Hauser

Endress+Hauser Proline Promag L 400 operating instructions

Vega VEGAPULS 66 operating instructions

Vega

Vega VEGAPULS 66 operating instructions

Fluidwell F115-P manual

Fluidwell

Fluidwell F115-P manual

PCB Piezotronics 3501B1260KG/010LN Installation and operating manual

PCB Piezotronics

PCB Piezotronics 3501B1260KG/010LN Installation and operating manual

socomec COUNTIS AT operating instructions

socomec

socomec COUNTIS AT operating instructions

Seametrics FT400 General information

Seametrics

Seametrics FT400 General information

Lika Rotacod MH58S Series Mounting instructions

Lika

Lika Rotacod MH58S Series Mounting instructions

Laserworld RGB-1.2 manual

Laserworld

Laserworld RGB-1.2 manual

PCB Piezotronics 3741B122G Installation and operating manual

PCB Piezotronics

PCB Piezotronics 3741B122G Installation and operating manual

IO Thrifty HUTX1-485 user manual

IO Thrifty

IO Thrifty HUTX1-485 user manual

Sola VECTOR 40 operating instructions

Sola

Sola VECTOR 40 operating instructions

Union Instruments CWD3000 EXP operating instructions

Union Instruments

Union Instruments CWD3000 EXP operating instructions

K-Patents PR-43 Series instruction manual

K-Patents

K-Patents PR-43 Series instruction manual

BEKA FOUNDATION BA444DF-F manual

BEKA

BEKA FOUNDATION BA444DF-F manual

Waters 2410 Operator's guide

Waters

Waters 2410 Operator's guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.