Proper Air Valve Wiring (continued)
Constant Power with Ground Switching
In this configuration, one wire from the solenoid is connected to
constant power and the other wire is connected through a pushbutton
switch that supplies ground when pressed. Connect the Pink output
wire from the through a relay (not included) as shown below.
ŸTurn off ignition - programming is complete.
TM
Sniper
Programming - Remote Fobs
If you wish to add fobs or replace lost/broken fobs they must be
TM
programmed into the Sniper .
ŸWith the ignition turned on, press and hold the programming button
for 3 seconds; the LED will turn solid.
ŸPress the button on the new remote, then press the button on all
other remotes you wish to keep programmed (up to 4).
Programming - Safety Inhibit
TM
The Sniper has a built in ‘safety inhibit’ that prevents the system from
activating when the vehicle is running. This feature can be turned
on/off by turning the ignition to the 'ON/RUN' position, then pressing the
programming button 5 times. When the LED flashes 3 times, the
Safety Inhibit is turned off. Perform the same process to turn the Safety
Inhibit on. When the LED flashes 5 times, the Safety Inhibit is
enabled.
Pink wire from Sniper
87
85
86
30
87a
+-
Battery