Contents
1. Instruction
1.1 Function & Feature
1.2 Specification
1.3 Standard packing list
1.4 Main unit layout
2. Installation
2.1 Install main unit
2.2 Install accessories
2.2.1 Install door/window magnetic contact
2.2.2 Install PIR motion sensor
2.2.3 Wireless shock sensor
2.2.4 Install smoke/gas detectors
2.2.5 Install the wired & wireless Infrared Fence detector
3. Operation steps
3.1 Turn on
3.2 Keypad setting
3.2.1 Password verification
3.2.2 Set/delete/check 6 mobile phone numbers for SMS alarm.
3.2.3 Set/delete/check 5 phone numbers for call alarm
3.2.4 Set/delete/check 1 SMS forwarding phone number
3.2.5 Recording voice
3.2.6 Change passwords
3.2.7 Change ID
3.2.8 Set date & time
3.2.9 Set/cancel fixed time arm/disarm
3.3 Learning code
3.3.1 Learn/cancel remote control.
3.3.2 Learn/cancel wireless sensors
3.3.3 Cancel all wireless accessories.
3.4 Exit setting
4. Zone classification
5. SMS command
5.1 Set/delete 5 mobile phone numbers for SMS alarm
5.2 Set/delete 5 phone numbers for call alarm
5.3 Set/delete 1 SMS forwarding phone number
5.4 Change password
5.5 Arm/disarm
5.6 Change zone name
5.7 Independent arm/disarm and inquiry
5.8 Delay alarm setting
5.9 Inquire arm/disarm status
5.10 Inquire external power status
6. Usage
6.1 Remote controller
6.2 Handfree mobile phone
6.3 Door/window open reminder
6.4 Sensors low voltage reminder.
6.5 Deal with alarm
6.6 Emergency alarm
6.7 External power failure alarm
6.8 Remote phone call control
7. Events record/History record
8. Operation Caution

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
- 3 -
1. Instruction
The alarm system adopts SMS data transmission and voice platform of GSM network to send control
command and receive alarm remotely, which is designed for house, office, supermarket etc indoor use. It will
call & send alarm SMS to user cellphones immediately when any sensor is triggered. The system can also be
used as handfree mobile phone for two-ways communication.
The LCD on the alarm Main unit can show the time, data, operation guide, alarm details and status of arm,
disarm, GSM signal, power etc. With the LCD, all the operation and program are visual and intuitive.
The system with human kind voice guide and can be recorded into all different kinds of languages and work
well all over the world. The low-voltage warning for sensors and door/window opened reminder make use
more friendly. The function in details as follows.
1.1 Function & Feature
●Color LCD screen, keypad with blue background light
●Maximum 4 wireless panic buttons, 4 wireless fire detectors,
16 remote controllers, 32 wireless intruder detectors.
●Maximum 8 wired zones. Zone 1 and zone 2 for wired door/window magnetic contact, which will remind you
if the door/window is open.
●Send alarm SMS to 5 preset mobile phone No.
●Auto dial 5 preset user phone No.
●Forward mobile company SMS to user automatically.
●Work with monitoring center, such as police station.
●Sensors low voltage reminder
●Learning code for wireless accessories
●Voice operation reminder.
●Recording voice
●Three level password management.
●Independent arm/disarm function
●Zone classification prevent inside thieves effectively.
●Two fixed arm time, two fixed disarm time
●2
20
wireless address encode reduce the rate of same code greatly.
●SMS control & program
●SMS modifies wireless zones name.
●Arm/disarm by keypad, remote controller, phone or SMS
●Call the main unit to listen in status whenever.
●With internal MIC and speaker.
●External high sensitivity MIC or speaker (optional)
●Main unit with tamper switch
●External power failure alarm.
●Entry delay alarm
●Two-way communication
●Handfree mobile phone.
●Event record

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
- 4 -
1.2 Specification
Main unit PARAMETER
GSM frequency 900/1800MHz, 850/1900MHz (optional)
Alarm response time Less than 10s (GSM in normality)
Standby power consumption 1.5W
Delay arm time 30s
Recording voice time 9s
External Power AC110-220V 50Hz or 60Hz; DC9V
Backup battery (Li) DC7.4V, 700MAH
Operating temperature -20 ~ 60℃ ℃
Humidity <95%
Accessories PARAMETER
Wireless frequency 315±0.2Mhz/433±0.2Mhz
Coding type Learning code
Power requirements Remote controller: DC12V battery
Indoor wired siren: DC12V battery
Door/window magnetic contact: DC12V battery
PIR sensor: 3V (two 1.5v batteries inside)
Smoke detector: DC9V battery
Gas detector: DC9V battery
Shock sensor: DC12V battery
Emergency button: DC12V battery
Fence detector: DC12V, 110V to 220V
Beam detector: DC12V, 110V to 220V
Lifespan of battery half year (trigger 20 times everyday)
Lower voltage reminder numerical value Door/window magnetic contact: ≤10.5V
PIR sensor: ≤2.2V
Shock sensor: ≤3.3V

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
- 5 -
1.3 Standard packing list
NAME QTY IMAGE Remark
Main unit 1pcs
Remote controller 2pcs Arm/disarm main unit
Indoor wired siren 1pcs
Wireless door/window contact
1pcs With low voltage reminder function
Wireless PIR sensor 1pcs
With low voltage reminder function
Adapter 1pcs /AC110-220V 50Hz or 60Hz; DC9V
User manual 1pcs /
Optional accessories
Shock Sensor Smoke Detector Gas Detector
Panic Button Fence Detector Beam Detector
Speaker External Microphone 626 siren
Strobe siren Outdoor strobe siren

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
- 6 -
1.4Main unit layout
Note: The background blue light under the disarm button is GSM signal indicator
Main unit back:

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
- 7 -
2. Installation
2.1 Install main unit
a) Insert a valid SIM card into main unit
Note: Make sure the SIM card is valid that can make call and send SMS.
b) Connect power, siren, microphone etc with main unit.
c) Fix and hide main unit
2.2 Install accessories
2.2.1 Install the door/window magnetic contact
The principle of door/window contact sensor
The door/window magnetic contact includes two parts. The sensor will send the wireless signal to the main
unit immediately when the two parts depart more than 15-30mm.
2.2.2 Install PIR motion sensor
PIR refers to passive Infra-red. A Passive Infra-red Sensor is an electronic device that detects the motion or
movement of some person or animal by sensing the heat emitted from the body.
Wireless scroll steel door magnetic sensor for scrolling steel door
Installation: Please see below picture
It is triggered when the two parts are separated to 3cm - 5cm.
2.2.3 Wireless shock sensor
Shock sensor including two parts, shock sensor and battery box. Put four 1.5v batteries into battery box, and
then fix it on the any place by double-faced tape.

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
Tel: +86-(0)755-86082432 E-mail: klalar[email protected] MSN: [email protected] Skype: securitykonlen
- 8 -
2.2.4 Install smoke/gas detectors
a) Wireless smoke detector
This smoke detector detects smoke by a couple of infrared diodes, which is suitable for detecting the smoke
in house, shop, hotel, restaurant, office building, school, bank, library and storehouse etc.
b) Wireless gas detector
The product is ceiling mounted gas detector with high stability. It is used for detecting leaking gas and suitable
for the safety of residential house, villas, hotels, boarding house etc.
Detecting the gas heavier than air: installation height from floor: 0.3m ~ 1.0m, semi-diameter to gas sources:
<1.5m; detecting the gas lighter than air: installation height from ceiling 0.3m ~ 1.0m, semi-diameter to gas
sources: <1.5m.
2.2.5 Install the wired & wireless Infrared Fence detector
In some circumstances the wired & wireless Infrared Fence detector is more appropriate than magnetic
sensors. i.e. veranda, picture window balcony, boundary wall.
3. Operation steps
3.1 Turn on
Make sure that the power supply is connected correctly, and turn on the main unit power switch. It will search
the GSM network automatically within 25 seconds after it is started. Then the LCD display turns on and shows
the status of arm, disarm, GSM signal etc. GSM network is normal when LED indicators under the disarm
button flash regularly. When the external power is normal, the LCD background light keeps on. If there is no
external power, it is off automatically after operation.

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
Tel: +86-(0)755-86082432 E-mail: klalar[email protected] MSN: [email protected] Skype: securitykonlen
- 9 -
3.2 keyboard setting
Note: When setting by the keyboard, every time you press the button you will hear “di” sound for
confirmation. Please press it again if there’s no voice. Press “CLS” button before inputting “OK” to
cancel the input numbers. If the LCD display shows “FAIL”, please check and set again.
3.2.1 Password verification
Press “SET”, the main unit remind: “please input password” with voice.” then input password + OK, you will
hear “di,di” sound for confirmation. While “SET” and “SMS” appear on LCD display, it means that the
password is correct.
Total three level password protection
Level
Type Factory
Password Functions
1 Administrator
Password 1234 Authorized to operation all. E.g. set, disarm,
inquiry, remote control etc.
2 Disarm Password
5678 Only for disarm
3 Inquiry Password
9012 Only for check whether the program is
correct or not.
3.2.2 Set/delete/check five mobile phone numbers for SMS alarm.
a) Set the mobile phone number
After passing the verification of administrator password, press “SET” button, when “SET, SMS” appears on the
LCD display, input: N + mobile phone number + OK
Note: N stands for 1, 2, 3, 4, 5.
Max 18 digits of phone numbers
Example: Set 1368888888 as the first SMS receiving mobile phone number, input: 1+ 1368888888 + OK,
then two sounds of “di, di” for confirmation.
According to the method, you can finish the setting of the other four mobile phone numbers.
b) Delete the mobile phone number
Input: N﹢“OK” for cancel.
c) Check the mobile phone number
Input: N + check, the programmed phone numbers will appear on the LCD for check.
3.2.3 Set/delete/check five phone numbers for call alarm
a) After passing the verification of administrator password, press “SET” button to move cursor, when “SET,
TEL” appears on the LCD display.
Input: N﹢phone number + OK
Note: N stands for 1, 2, 3, 4, 5
The phone number can be mobile phone or telephone (Max 18 digits)
Example: Set 1368888888 as the first alarm call receiving phone number, input: 1 + 1368888888 + OK, then
two sounds of “di, di” for confirmation.
b) Delete the phone number
Input: N﹢OK for cancel
c) Check the phone number
Input: N + check, the programmed phone numbers will appear on the LCD for check.
3.2.4 Set/delete/check one SMS forwarding phone number

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
Tel: +86-(0)755-86082432 E-mail: klalar[email protected] MSN: [email protected] Skype: securitykonlen
- 10 -
The messages from the pre-set phone number can be forwarded to the first alarm SMS receiving
phone number. Recommend users to set the mobile company phone number so that users can know
the SIM card status of main unit timely to make sure normal communication.
a) After passing the verification of administrator password, press “SET” button, when “SET, SMS” appears on
the LCD display.
Input: N﹢phone number + OK
Note: N stands for 6
Example: The mobile company phone number is 10086,
The preset first alarm SMS receiving phone number. is 1368888888
Input: 6 + 10086 + OK, then two sounds of “di, di” for confirmation.
When the mobile company sends a SMS of “Your mobile no enough money, please charge soon”, the
message will be forwarded to 1368888888 automatically.
Note: The phone number can be deleted and checked as per the point b) & c) of 3.2.2/ 3.2.3
3.2.5 Record voice
After passing the verification of administrator password, press ”SET” button to move cursor, when “SET, REC”
appear on the LCD display, press “OK” to begin the 9 seconds record. The main unit LCD starts to count down
and exits automatically in 9 second. Press “CHECK” to play the record.
3.2.6 Change password
After passing the verification of administrator password, press “SET” button to move cursor, when “SET, PAS”
appears on the LCD display, operate as below
Example: Set 4321 as the new administrator password.
Input: 1 + 4321 + “OK”, then you will hear “di, di” sound for confirmation.
3.2.7 Change ID
After passing the verification of administrator password, press “SET” button to move cursor, when “SET, ID”
appears on the LCD display, input: six new ID numbers + OK,
Note: the initial ID is 000000.
Example: Set 123456 as the new ID.
Input: 123456 + “OK”, then two sounds of “di, di” for confirmation.
Press “check” to inquiry the new ID
3.2.8 Set data & time
After passing the verification of administrator, press “SET” to move cursor, when “SET, ” appears on the
LCD display,
Input: * + year/month/day/hour/minute/second (each with two numbers) + OK, then you will hear “di, di” sound
Level Type Factory password
Changing command Check new
password
1 Administrator
Password 1234 1 + new password +
OK 1+ check
2 Disarm Password 5678 2 + new password +
OK 2 + check
3 Inquiry Password 9012 3 + new password +
OK 3 + check

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
Tel: +86-(0)755-86082432 E-mail: klalar[email protected] MSN: [email protected] Skype: securitykonlen
- 11 -
for confirmation.
Example: Suppose the present time is 12:13.05 and the date is 08-01-2007, input * + 070108121305+OK.
3.2.9 Set/cancel fixed time arm/disarm
a) Timing arm
Press “SET ” to move cursor, when “SET, ” appears on the LCD display, then Input: N + time (hour/ minute)
+ OK. Two sounds of “di, di” will confirm the operation.
Note: N stands for 1 and 2, two fixed time arm can be set.
Example: Set 16:08 and 22:30 as the auto arm time,
Input 1 + 1608 + OK, and 2 + 2230 +OK. The main unit will be armed automatically at 16:08 and 22:30.
For inquiry, press 1 + check and 2 + check
To cancel it, press N + 9999 + OK in arm mode.
b) Timing disarm
Press “SET” button to move cursor, when “SET, ” appears on the LCD display, then input: N + time
(hour/minute) + OK. Two sounds of “di, di” will confirm the operation
Note: N stands for 3 and 4, two fixed time disarm can be set.
Example: Set 19:25 and 7:30 as the auto disarm time, input 3 + 1925 + OK, and 4 + 0730 + OK. The Main
unit will be disarmed automatically at 19:25 and 7:30
For inquiry, press 3 + check and 4 + check
To cancel it, press N + 9999 + OK in disarm mode.
3.3 Learning code
3.3.1 learn/cancel remote controller.
a) Learn remote control
After passing the verification of administrator password, press “SET” button to move cursor, when “SET,
COM” appears on the LCD display, input: 1 + N + OK, the LCD flashes then trigger the remote controller
immediately. It means successful learning when the LCD background light stops flashing and with voice
reminder “Learning code finished”. It will exit automatically if learning code failure within 10s. Please learn
again.
Note: N stand for 01, 02, 03, 04………16, total 16 remote controllers you can learn.
Example: learn first remote controller, input 101OK on keyboard of main unit.
b) Cancel remote controller.
After passing the verification of administrator password, press “SET” button, when “SET, COM” appears on
the LCD display, input * + N + OK, the LCD will flash three seconds, then stop. The remote controller is
deleted successfully. Note: N stand for 01, 02, 03, 04………16.
3.3.2 Learn/cancel wireless sensors
a) Learn wireless sensors
After passing the verification of administrator password, press “SET” button, when “SET, COM” appears on
the LCD display, input: 2 + N + OK, the LCD flashes then trigger the wireless sensor immediately. It is learnt
successfully when the LCD stops flashing. No success within 10s, it will exist learning status automatically,
please do it again according to above steps.
Note: N stand for 01, 02, 03, 04………40, total 40 wireless sensors you can learn.
Zone 01 to 32 for common wireless sensors, such as wireless PIR sensor, door/window magnetic
contact, glass break sensors etc.

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
Tel: +86-(0)755-86082432 E-mail: klalar[email protected] MSN: [email protected] Skype: securitykonlen
- 12 -
Zone 33 to 36 for wireless fire alarm detectors, such as wireless smoke/gas detectors
Zone 37 to 40 for wireless emergency button
Example: learn first wireless PIR sensors, press 201OK on keyboard of main unit.
Learn first wireless smoke detectors, press 233OK
Learn the second wireless emergency button, press 238OK.
b) Cancel wireless sensors.
After passing the verification of administrator password, press “SET” button, when “SET, COM” appears on
the LCD display, input # + N + OK, the LCD will flash three seconds, then stop. The wireless sensor is deleted
successfully. Note: N stand for 01, 02, 03, 04………40.
3.3.3 Cancel all the wireless accessories.
After passing the verification of administrator password, press “SET” button, when “SET, COM” appears on
the LCD display, input 999 +OK on Main unit keyboard, the LCD will stop to flash in 4s. All of them are
deleted.
3.4 Exit setting
In the setting mode, press “ESC” to exit. The setting mode will exit automatically if no response within 15
seconds.
4. Zone classification
Total 40 wireless zones, each zone can only learn one wireless sensor.
01-28: common zones
01-24: can be programmed as independent arm/disarm zone
29-30: special zones
*Only fifteenth remote controller can arm/disarm it,
* Only send alert to the preset forth alarm receiving phone number.
* The fifteenth remote controller can control 01 to 28 and 29, 30.
31-32: special zone
*only sixteenth remote controller can arm/disarm it.
*only send alert to the preset fifth alarm receiving phone number.
*The sixteenth remote controller can control 01 to 28 and 31, 32
33-36: 24 hours (full day arm) fire alarm zone for wireless gas/smoke detectors.
37-40: 24 hours (full day arm) emergency zone for wireless panic button.
Example:
CEO room
Zone 29
GM Room
Zone32
Financial dept
Zone 01
Personnel dept
Zone 02
Marketing Dept
Zone 03
Customer service
Dept zone 04
R & D dept zone 05 Engineering dept zone
06
Shipping dept
zone 07
Purchasing dept
zone 08
Ware house
09
Production dept
10

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
Tel: +86-(0)755-86082432 E-mail: klalar[email protected] MSN: [email protected] Skype: securitykonlen
- 13 -
CEO with 15
th
remote controller,
General Manager with 16
th
remote controller.
Financial dept zone 01 is programmed as independent arm/disarm zone.
Personnel dept with 02 remote controller.
*CEO arm/disarm 15
th
remote controller, all the zone is armed/disarmed except for zone 32 and zone 01
*General Manager arm/disarm 16
th
remote controller, all the zones are arm/disarm except for 29 and zone 01.
*Personal dept arm/disarm 2
nd
remote controller, all the zones are armed/disarmed except for zone29, 32, 01,
* Financial dept is independent arm/disarm zone, only SMS can arm/disarm it.
*CEO room is triggered, only send alert to the forth pre-set phone number.
*General Manager is triggered, only alert to the fifth pre-set phone number.
Zone classification solution can prevent inside thief infectively.
5. SMS control command
5.1 Set/delete five mobile phone numbers for SMS alarm.
a) Set the mobile phone number
SMS format: four digits of administrator password + DS + N + mobile phone number.
Note: N stands for 1, 2, 3, 4, 5
Example: Set 1388888888 as the first SMS receiving mobile phone number. The Main unit’s administrator
password is 1234.
Send SMS: 1234DS11388888888
b) Delete the mobile phone number
SMS format: four digits of administrator password + DS + N.
5.2 Set/delete five phone numbers for call alarm
a) Set the phone number
SMS format: 4 digits of administrator password + DT + N + phone number.
Note: N stands for 1, 2, 3, 4, 5; the phone No. can be telephone or cell phone
Example: Set 01088888888 as the first phone number for auto-dialing alarm. The Main unit’s administrator
password is 1234.
Send SMS: 1234DT101088888888
b) Delete the phone number
SMS format: four digits of administrator password + DT + N.
5.3 Set/delete one SMS forwarding phone number
The messages from the pre-set phone number can be forwarded to the first alarm SMS receiving
phone number. Recommend users to set the mobile company phone number so that users can know
the SIM card status of main unit timely to make sure normal communication.
a) Set the phone No.
SMS format: 4 digits of administrator password + DS + N + phone number.
Note: N stands for 6; the phone No. can be telephone or cell phone.

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
Tel: +86-(0)755-86082432 E-mail: klalar[email protected] MSN: [email protected] Skype: securitykonlen
- 14 -
Example: The mobile company phone number is 10086,
The preset first alarm SMS receiving phone No. is 1368888888
The administrator password is 1234
Send SMS: 1234DS610086 to main unit
When the mobile company sends a SMS of “Your mobile no enough money, please charge soon”, the
message will be forwarded to 1368888888 automatically.
b) Delete the phone number
SMS format: four digits of administrator password + DS + 6.
5.4 Change password
SMS format: 4 digits of administrator password + DP + 4 new numbers for password
Example: The initial password is 1234, if you want to set 5678 as the new password,
Send SMS: 1234DP5678.
5.5 Arm/disarm
Arm by SMS: 4 digits of administrator password +A1
Disarm by SMS: 4 digits of administrator password +A2
Example: The Main unit’s administrator password is 1234. If you want to set the Main unit in arm mode.
Send SMS: 1234A1
5.6 Change zone’s name
SMS format: 4 digits of administrator password + DM + zone’s code (2 digits) + changed name
Reply SMS: the new zone’s name
Example: The administrator password is 1234. If you want to change zone 06’s name to be “PIR alarm for
bedroom”.
Send SMS: 1234DM06 PIR alarm for bedroom
Note: Changed name should be less than 24 characters.
5.7 Independent arm/disarm and inquiry
a) Independent arm
SMS format: Administrator password + AA+ Zone (01, 02, 03...23, 24)
Example: The administrator password is 1234.
Arm zone 01, 03, 04 independently, send main unit a SMS of 1234AA01, 03, and 04 to arm them. The preset
five SMS receiving phone number will receive a SMS from main unit as below:
Unit_ID: 000000
Zone type
01-A
02-
03-A
04-A
05-
….
23-
24-

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
Tel: +86-(0)755-86082432 E-mail: klalar[email protected] MSN: [email protected] Skype: securitykonlen
- 15 -
Note: A stand for independent arm zone
Zone01 to 24 can be programmed as independent arm/disarm zones which only SMS can arm/disarm
them, no use by remote controller).
b) Inquiry independent arm zone
By the main unit keypad: After passing the verification of administrator password, press “SET” button to move
cursor, when “SET, TYPE” appears on the LCD screen, press "check". Then main unit send a SMS like above
example to the preset five SMS receiving phone numbers.
By SMS: Send a SMS order like this: Administrator password + AA to main unit, then main unit reply a SMS
about the independent arm/disarm zone information to preset five SMS receiving phone numbers
c) Independent disarm
Send SMS: Administrator password + AD + zone (01, 02...24) to disarm the preset independent arm zones.
5.8 Delay alarm setting
SMS format: 1234 + zone number ( 1 or 2) + D + delay alarm time (00s, 15s, 30s or 45s)
Note: Zone 1 and zone 2 can be set as delay alarm zones.
Suggest users to install the delay alarm zone sensors on the way from door to alarm main unit.
User will have enough time to disarm the alarm system while entering into the house.
Example: Set zone 1 and zone 2 as delay alarm zones, and the delay alarm time is 30s.
Send SMS: 12341D30 and 12342D30 to alarm main unit by two separate SMS.
The alarm system will make “ DI, DI, DI….” sound to remind user to disarm it soon whe n entering into the
house. The system will make alarm immediately in 30s if the system is still not be disarmed.
5.9 Inquire arm/disarm status
Send SMS: 4 digits of administrator password + W1
Reply SMS: The Main unit’s arm/disarm status
5.10 Inquire external power status
Send SMS: 4 digits of administrator password + W2
Reply SMS: The Main unit’s external power status
6. Usage
6.1 Remote controller
a) Delayed Arm: Press “ ” on remote controller or main unit, the main unit is counting down with “di,di…”
sound and red “ ” icon on LCD is flashing. 25 second later, two long “di, di” sound confirm the system enter
into arm status and the “ ” icon stops to flash.
b) Quick arm: Press “ ” on remote controller and then press “ ” immediately, the system is armed quickly.
c) Emergency alarm: Learning code the “ ” as panic button first, press “ ”, the main unit auto-dial the

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
Tel: +86-(0)755-86082432 E-mail: klalar[email protected] MSN: [email protected] Skype: securitykonlen
- 16 -
preset phone numbers and send SMS of “Emergency alarm” to ask for help.
d) Disarm: Press “ ” on remote controller to disarm the system. The “ ”icon on LCD is on.
Press the big round disarm button on main unit, the system remind of inputting password. It is armed
successfully after passing password identification.
6.2 Handfree mobile phone
The main unit can be used as mobile phone.
a) Make a phone call
Press “*”, the main unit LCD shows “TEL”, then input: phone number + OK to make a call.
Press “ESC” to hand up the phone call. “CLS” clear the wrong numbers.
a) Answer the incoming call.
The main unit voice “ di di” when there is a incoming call. Press “OK” to answer it, ESC button hand up the
phone call.
6.3 Door/window open reminder
The LCD show “ Door/window is open” with voice warming when user arm it if the door/window in wired zone
1 and zone 2 is not closed.
6.4 Sensors low voltage reminder
The main unit sends SMS of “the sensors with no voltage” to first SMS receiving mobile phone, and the LCD
show “LO + zone number” to remind of users change battery.
6.5 Deal with alarm
“ ”, “SMS”, “TEL” and zones appear on the LCD display in alarm mode (P: external power failure, E:
Emergency alarm, F: fire alarm, 01-32: wireless sensors alarm). The siren sounds loudly for 90 seconds to
inform the neighbors. At the same time, the system automatically sends SMS alert and auto-dial the preset
phone numbers. The user can listen to the prerecorded voice warming and what happened in alarm area
when any phone is answered and remotely operate as follow,
Press “1”-------------------the Main unit armed
Press “2”-------------------the Main unit disarmed
Press “3”-------------------drive siren
Press “4” ------------------close siren
Press “*”-------------------two way communication
Press “#”-------------------Stop to call the next phone numbers.
The system will auto-dial the next phone number if the phone line is busy or can’t put through. It will stop to
call the next one when somebody answer the phone and press “#”. If nobody answers the phone, the system
will stop dialing after auto-dialing circularly for three times.
6.6 Emergency alarm
Press “ ” on remote control or the emergency button, the Main unit auto-dial the preset phone numbers and
send SMS of “Emergency alarm” to ask for help.
6.7 External power failure alarm
When the system checks out that there is something wrong with the external power or the external power is
off for more than 2 seconds, it makes alarm call immediately and send SMS of “External power failed”. The

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
Tel: +86-(0)755-86082432 E-mail: klalar[email protected] MSN: [email protected] Skype: securitykonlen
- 17 -
system stops alarming immediately and send SMS of “External power is OK” when the power supply is OK.
6.8 Remote phone call control
You can use any telephone/mobile phone to dial the phone number of main unit. If no body answers the phone,
the system will automatically get connected and remind you of inputting password with voice. If the entered
password is wrong for 3 times, the main unit will hand up the phone automatically; if the entering password is
right, you can listen in and control it by pressing the phone keypad.
Press “1”-------------------- system armed
Press “2”--------------------- system disarmed
Press “*”----------------------close siren and two way communication
If the user hand up the phone, the host will automatically terminate the operation.
7. Events record/History record
a) After passing the verification of administrator password, press “SET” button to move cursor, when “SET,
” appears on the LCD display, press "(01,02,03...32)" + "check". Then you can the see the message on
the LCD likes below:
"A0" + "09" + "02" + "08" + "13" + "20"
A0 is event code
09 is the year.
02 is the month
08 is the day
13 is the hour
20 is the minute
00, 01, 02 ...32 is the order of event.
b) Event code
FF invalid event
71 armed by main unit keypad
72 armed by SMS or TEL
73 disarmed by main unit keypad
74 disarmed by SMS or TEL
76 external power failures
77 external power OK
78 fixed time arm
79 fixed time disarm
7E forwarded SMS
7F main unit reboot
90 arm by 1
st
remote controller
91 arm by 2
nd
remote controller
92 arm by 3
rd
remote controller
93 arm by 4th remote controller
94 arm by 5th remote controller
95 arm by 6th remote controller
96 arm by 7th remote controller
97 arm by 8th remote controller
98 arm by 9th remote controller

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
Tel: +86-(0)755-86082432 E-mail: klalar[email protected] MSN: [email protected] Skype: securitykonlen
- 18 -
99 arm by 10th remote controller
9A arm by 11th remote controller
9B arm by 12th remote controller
9C arm by 13th remote controller
9D arm by 14th remote controller
9E arm by 15th remote controller
9F arm by 16th remote controller
A0 disarm by 1
st
remote controller
A1 disarm by 2
nd
remote controller
A2 disarm by 3
rd
remote controller
A3 disarm by 4th remote controller
A4 disarm by 5th remote controller
A5 disarm by 6th remote controller
A6 disarm by 7th remote controller
A7 disarm by 8th remote controller
A8 disarm by 9th remote controller
A9 disarm by 10th remote controller
AA disarm by 11th remote controller
AB disarm by 12th remote controller
AC disarm by 13th remote controller
AD disarm by 14th remote controller
AE disarm by 15th remote controller
AF disarm by 16th remote controller
01 wireless zone 01 alarm
02 wireless zone 02 alarm
03 wireless zone 03 alarm
04 wireless zone 04 alarm
05 wireless zone 05 alarm
06 wireless zone 06 alarm
07 wireless zone 07 alarm
08 wireless zone 08 alarm
09 wireless zone 09 alarm
0A wireless zone 10 alarm
0B wireless zone 11alarm
0C wireless zone 12 alarm
0D wireless zone 13 alarm
0E wireless zone 14 alarm
0F wireless zone 15 alarm
10 wireless zone 16 alarm
11 wireless zone 17 alarm
12 wireless zone 18 alarm
13 wireless zone 19 alarm
14 wireless zone 20 alarm
15 wireless zone 21 alarm
16 wireless zone 22 alarm
17 wireless zone 23 alarm

KONLEN TECHNOLOGY LIMITED
Website: www.konlen.com
U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China
Tel: +86-(0)755-86082432 E-mail: klalar[email protected] MSN: [email protected] Skype: securitykonlen
- 19 -
18 wireless zone 24 alarm
19 wireless zone 25 alarm
1A wireless zone 26 alarm
1B wireless zone 27 alarm
1C wireless zone 28 alarm
1D wireless zone 29 alarm
1E wireless zone 30 alarm
1F wireless zone 31 alarm
20 wireless zone 32 alarm
21 fire zone 01 alarm
22 fire zone 02 alarm
23 fire zone 03 alarm
24 fire zone 04 alarm
25 emergency zone 01 alarm
26 emergency zone 02 alarm
27 emergency zone 03 alarm
28 emergency zone 04 alarm
29 wired door/window zone 01 alarm
2A wired door/window zone 02 alarm
2B wired zone 03 alarm
2C wired zone 04 alarm
2D wired zone 05 alarm
2E wired zone 06 alarm
2F wired zone 07 alarm
30 wired zone 08 alarm
31 tamper switch alarm
8. Operation Cautions
1. The equipments are not water-proof, not suitable for outdoor use.
2. Install the system in a hidden place.
3. Turn off the power supply before insert/take out the SIM card.
4. Connect the power supply firmly and provide good heat dissipation.
5. Don’t install the system close to the objects which generate strong magnetic interference, such as
TV set and computer.
6. Check all the detectors and their battery in time and change them when voltage is low.
7. Check the GSM alarm system regularly.
Table of contents
Other Konlen Security System manuals
Popular Security System manuals by other brands

DEXAPLAN
DEXAPLAN CA 616 - 8-2006 Operation and safety notes

SMART
SMART TL-5116R Quick start instructions

Apollo
Apollo XP95 IS installation guide

Essentials
Essentials EL00160 manual

Response
Response CWK5 Installation and operating instructions

WHITECROFT LIGHTING
WHITECROFT LIGHTING Routefinder user manual