CAUTION
1." DO NOT BLOCK VENTILATION "! Please keep everything away from the inlet and outlet ventilation.
2. Operate this unit on a flat horizontal surface to avoid water leak.
3. DO NOT operate this unit in an explosive or corrosive atmosphere.
4. The appliance shall be installed in accordance with national wiring regulations.
5. Clean air filter periodically to enjoy the most efficient dehumidify.
6. This unit needs at least 3 Amps of electricity to have its heater kicked in. To avoid the household electricity block out, please
do not use any extension cord for this unit.
7. This unit is for indoor use only.
8. DO NOT place objects on top of the unit.
9. DO NOT use the unit without the AIR FILTER.
10. DO NOT unplug the unit if your hands are wet, Electrical shock could occur.
11. DO NOT carry the unit while it is operating.
12. DO NOT unplug the unit unless you have stopped the unit by press the “power” key and make sure the motor fan is
stopped.
13. When the supply cord is damaged, it must be replaced by the manufacturer , its service agent or similarly qualified
persons in order to avoid a hazard.
14. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the
appliance.
15. The devices should be installed at minimum distant of 50CM from the wall or other obstacle.
16. Unplug the appliance before cleaning.
CAUTION!
BEFORE POWER ON
PLEASE OPEN THE AIR-OUTLET COVER COMPLETELY

OPERATING INSTRUCTIONS
1. Control panel
2. Air outlet
3. Side panel
4. Front panel
5. Air inlet
6. Back panel
7. Water tank
8. Wheel leg
CONTROL PLATE DESCRIPTION
OPERATION INSTRUCTION
1. POWER KEY Press to turn unit “ON” or “OFF”.
2. FAN SPEED Press the key to select fan speed “HI” or “LOW”.
3. TIMER a. Press the key to timer setting desired (1~24 hour).
b. Once the set time has come to an end, the unit will turn off automatically.
c. Pressing the “POWER” key before the set time has been reached will cause the set time to be cancelled
when the unit turns off.
Press the key to set the humidity desired (RH60%,65%,70%,75%,80%, CONTINUOUS,40%,45%,50%,55%).
4. When the room humidity is less than the set humidity within 5% then the compressor will turn off automatically , until
the room humidity is higher than the set humidity by 5% again.
5. TANK FULL
If this indicator illuminates, it means tank is full of water, and unit will operate with the fan only (The compressor will
stop running automatically,) until the tank was empty

PRECAUTIONS
1. The operational temperature range for this unit is 5-35℃.
2. If the dehumidifier does not start (the operational light does not illuminate) or the dehumidifier makes
intermediate stop for unknown reasons, please check the plug and power supply for a poor connection. If the
plug and power supply are in normal condition, wait for 10 minutes and restart the unit (because take about
10 minutes to reset). If the unit still does not starts in 10 minutes, please contact your local retailer for repair.
3. When the dehumidifier is in operation, the running compressor will produce heat and make the room
temperature higher. This is normal..
USE OF WATER STORAGE TANK
1. Please unplug the stopper before starting the unit. (See Fig.01)
2. When the water tank is full, the water lever indication lamp will light and the unit will stop working. Please plug
the drain hose using the stopper first and then take out the water tank to empty the water. (See Fig.02)
3. Install the empty water tank back to its position and unplug the stopper. Then the unit can continue its
operation.
CONTINUOUS DRAINAGE
When you want to use this function, please take out the rubber drain stopper, and plug in a discharge water pipe
in.

MAINTENANCE INSTRUCTION
1. Do not locate on a floor with a soft oruneven surface when the unit is in operation to avoid
occurrence of vibration and noise.
2. Never insert any slim rod or hard object into the unit body to avoid occurrence of hazard or unit
failure.
3. During power off or when not in use for a long time, please disconnect the power cord from the
outlet.
4. For a better dehumidifying effect, the areas in front and rear of the unit should be clear and
free from obstacles, which will block the air flow for the unit.
5. Clean the filtering net once every two weeks (never use alcohol, gasoline or hot water with a
temperature above 40 degrees C.
CABINET
Wipe with a damp cloth and polish with a soft cloth.
To remove the air filter, please follows the arrow direction and draw the filter lightly, and then take out the
filter for cleaning.

SPECIFICATIONS
MODEL
SPECIFICATION Comfort25
POWER SUPPLY
POWER INPUT 500W
REFRIGERANT 180 g
MOISTURE
REMOVAL
(30℃ RH 80%)
25
liters/day
TEMP. RAHGE FOR
USE ℃
(CE) N 842/2006:
R134A is a kind of fluorinated greenhouse gases covered by
the Kyoto Protocol.
Its total global warming potential (GWP) is 1300
This marking indicates that this product should not be disposed with
other household wastes throughout the EU. To prevent possible
harm to the environment or human health from uncontrolled waste
disposal, recycle it responsibly to promote the sustainable reuse of
material resources. To return your used device, please use the
return and collection systems or contact the retailer where the
product was purchased. They can take this product for
environmental safe recycling.
Table of contents
Other Koolbreeze Dehumidifier manuals