MAINT NANC OF TH PHOTOVOLTAIC MODUL S
Photovoltaic modules re uiring very little maintenance due to their own design, with no moving parts and with an interior cell circuit soldering isolated
from the environment by protecting materials. At the same time the uality control performed by Korax Solar is very strict.
Maintenance may include one or several of the following steps:
Regular cleaning of the module
Visual inspection of possible internal degradation of the module sealing
Check out of the condition of electric connectors and wiring
Occasionally, checking out the electrical characteristics of the module
Regular cleaning of the modules
Dirt piled up on the transparent surface of the module reduces its performance and may cause reversal effects similar to those caused by shadows. The
layers of dust that reduce evenly the sun intensity are not dangerous and power reduction is not usually significant. In many cases the rainfall can
reduce or remove the dirt to an acceptable level.
The spot dirt is advisable to remove by occasional cleaning by washing the modules with water or some nonabrasive detergent.
Visual inspection of the module
The aim of the visual inspection of the modules is to detect the possible faults, like broken glass and/or corrosion of the circuits elements, mostly due to
humidity leakage at the damaged insulation spots or glass breakage. Consult your area dealer or Korax Solar in case of serious damage.
Check out the connections and cabling
The regular check-out of connections tightness and cable conditions considered as a preventive maintenance step.
SP CIFICATIONS/PRODUCT OV RVI W
PHYSICAL AND ELECTRICAL CHARACTERISTICS
KS-90 KS-180 KS-180L KS-240
PHYSICAL
Dimensions 1224 x 545 x 39.5 mm 1224 x 1047 x 39.5 mm 1600 x 800 x 39.5 mm 1657 x 977 x 39.5 mm
Weight 9 kg 15 kg 15 kg 19 kg
Number of cells 36 72 72 60
Size of cells 5” 5” 5” 6”
ELECTRICAL (1000 W/m
2
, 25
o
C cell, AM 1.5)
Nominal voltage (Vn) 12 V 24 V 24 V 24 V
Maximum power (Pmax) 90 Wp 180 Wp 180 Wp 240 Wp
Short-circuit current (Isc) 5,23 A 5,23 A 5,23 A 8,39 A
Open circuit voltage (Voc) 21,7 V 43,42 V 43,42 V 37,44 V
Maximum power current (Imax) 4,90 A 4,90 A 4,90 A 7,88 A
Maximum power voltage (Vmax) 18,61 V 37,25 V 37,25 V 31,2 V
DESIGN
Cells Monocrystalline Si, textured and covered with antireflection layer
Contacts Redundant contacts on each cell for circuit reliability
Laminate EVA (Ethylene-vinyl acetate)
Front face Tempered glass with improved light transmission
Rear face Tough multilayered backsheet Tedlar
Frame Anodised aluminium
Connection boxes IP 65 with built-in bypass diode
Cable cross section 4 mm
2
Connection box Pression screw with possibility of soldering, MC optional
PHYSICAL AND ELECTRICAL CHARACTERISTICS