Kosher NOGA SHABBAT NOGA-SH-241206 User manual

A Healthy Choice
Safety, operation, and installation instructions
for Water Dispenser model
NOGA-SH-241206
NOGA SHABBAT
US WATER. - 3740 SW 51st St Fort Lauderdale, FL 33312 USA

System components:
No.
System Features
No.
System Features
1
Chilling system power on/off
13
Time setting pushbutton
2
Heating system power on/off
14
Normal / Sabbath mode toggle pushbutton
3
Water IN port
15
Cold water dispense button
4
Excess cold water OUT port
16
Lukewarm water dispense button
5
Power supply cord 115V
17
Hot water button guard
6
Excess hot water OUT port
18
Hot water dispense button
7
LCD screen display
19
Cold water dispenser nozzle
8
DOWN button
20
Lukewarm water dispenser nozzle
9
UP button
21
Hot/boiling water dispenser nozzle
10
HALF/FULL hot water tank setting button
22
Indicator float for drip tray
11
Quick heating button
23
Drip tray
12
Temperature and time setting button
System Features:
1. This system is a system for the supply of hot and cold drinking water. In order to install it, you should connect it to a
water supply point and to an electrical outlet.
2. This system is easy to service and to maintain.
3. This system is equipped with a powerful and efficient compressor.
4. This system is a unique and effective system for the supply of hot water and cold water on Sabbath and on
weekdays.
Hot water temperature 80°C-96°C
Operating voltage: 115V-60Hz
Cold water temperature 7°C-15°C
Water ingress protection standard: IPx1
Ambient temperature 10°C-38°C
Gas type and weight: R134a/29gr
Heating system power consumption during operation:
800W+60W(PTC)
Climate Class: Class T 43+/-1 degrees
Refrigeration system power consumption during operation:
90W
Water pressure 3 bar / 0.3 MPa
Total power consumption: 890W
Water tank volume –Cold 3.5 Liters / Hot 7.2 Liters
Drinking water heating and chilling system, removes group Ismell and odor, removes Chlorine 75%

Installation instructions
1. Position the water dispenser in a dry, levelled location.
2. This device is intended for indoor use, the system should be placed in a shaded place, away from the sun.
3. The device should be placed at least 20 cm away from the rear wall.
4. It is recommended to install the system away from other electrical products in order to prevent unexpected damage
such as flooding, overheating, and to prevent heating from a nearby product.
5. It is necessary to install upstream of the water connection a pressure reducer (mandatory*). Please note that this
system does not withstand water pressure above 3 bar / 0.3 MPa.
6. Choose a convenient faucet to attach the system’s water supply, add a shut-off valve (for servicing/maintenance),
and connect the water supply water to the water IN port.
* A pressure reducer must be installed in order to regulate the pressure to 3 bar maximum.
7. Slowly open the water supply faucet, confirm that there are no leaks from the connections and/or the device.
8. Wait (2-3 minutes) and confirm that the water flowing from the dispenser nozzles is free of air bubbles and that the
flow is steady.
9. Flow water through the system for flushing prior to use.
10. After water comes out through the hot/cold dispenser nozzles, plug the device in to the electrical outlet.
Turn on cold water pushbutton and then turn on hot water pushbutton to power on hot and cold-water system.
11. If a water purification system is installed, it should be connected in accordance with the attached instructions.
Important: perform a rinse of the filters before connecting them to the system.
Important note: If combined with reverse osmosis, first flow regular water to full the tanks installed in the device
and only then connect to osmosis in accordance with the instructions.
WARNING!!
In the event of notices from the Ministry of Health of from the relevant authority regarding sanitary oversight, you must boil the
drinking water and follow their instruction.
It is mandatory to install a pressure reducer upstream of system and the pressure shall not exceed 0.3 MPa / 3 bar.
It is mandatory to install a combined sediment filter, to prevent sediment accumulation in the system.
It is important to note that the pressure varies and may increase at night and on weekends, therefore the device must be
disconnected from water and electricity supply during absence from the home or business on nights, weekends, and holidays and
this is to prevent hazards of leakage and electrical short circuits.
It is mandatory to replace filters and wash the internal system every 6-8 months to prevent the accumulation of bacteria and
sediments and to preserve the device and water quality. It is necessary to use special sediment filters.
Do not open the device. Device installation and filter replacement shall only be done by company-certified technicians.
The company is not responsible for any damage caused by water pressure in excess of the requirements and/or sediment damage.
Any work not performed by a company-certified technician voids the warranty for this product and the customer is then solely liable
for any resulting damage.
Warranty directly from the importer is conditional on installation by a technician supplied by the importer only!
(its realization in accordance with the conditions of a signed warranty agreement).
Importer warranty shall not apply when the installation of the water dispenser is performed by another installer.
Important Notes
1. It is mandatory to install a pressure reducer upstream of the water connection port.
2. The system shall only be installed by a company-certified technician.
3. In case the power supply cord has been damaged, it must be replaced only at a service lab approved by the importer.
4. Do not unplug the power supply cord in order to shut down the device, only use the power switches.
5. Do not clean the device with water (to avoid electrocution). It is recommended to clean the device with a damp cloth and then dry it
thoroughly.
6. It is forbidden to let small children use / operate / access the operation of the device.
7. Do not move the device or tilt it while it is plugged in to electrical supply.
8. Do not tilt the device more than 45 degrees during operation.
9. Flush the system during the first two weeks of use by emptying the water tanks 2-3 times daily to remove aftertastes.
(the device shall be disconnected from electrical supply using the power on/off switch and then the tanks shall be emptied of water
through the overfill port located at the bottom rear part of the device.
10. The company is not responsible for the device and for any other damage in the event that the device was not installed and regularly
maintained by a company-certified technician.

Operating Instructions
Heating
1. Switch on the heating switch located at the top rear side of the device. The word “Heating” will appear on the
screen, the icon will flash and turn solid when the heating process is completed and then enter heat hold state.
2. Setting hot water temperature: press the “SET” button and hold for 10 seconds. The hot water temperature will
flash on the display. Now press “UP arrow”, “DOWN arrow” to set the hot water temperature. Hot water setting
options are 87°C, 91°C, and 96°C, which will be indicated by the icons on the display screen. After setting the
temperature, press the “SET” button again in order to switch to cold water temperature and press the “SET” button
again to save the setting. (If there is no activity for 20 seconds in setting mode, last state is automatically saved).
3. When user selects 87°C, two small bars indication will be displayed on the LCD screen.
When user selects 91°C, two medium bars indication will be displayed on the LCD screen.
When user selects 96°C, two tall bars indication will be displayed on the LCD screen.
When selecting the desired temperature icon will flash until the water temperature reaches the temperature
that was just selected, and the icon will then turn solid.
SET
TIME
HALF/FULL
Tank
Quick Heating
Heat
Chill
Quick Heating
NOGAH SABBATH
SET CLOCK
FULL TANK
HALF TANK

Chilling
1. Switch on the chilling switch located at the top rear side of the device. The word “Chilling” will appear on the screen.
In this mode, the compressor activates to chill the water and the icon will flash. When the compressor operation
ends and enters chilling hold state, the icon will stop flashing and appear.
2. Setting cold water temperature: press the “SET” button and hold for 10 seconds. The hot water temperature will
flash on the display. Now press the “SET” button again to switch to cold water. Now press “UP arrow”, “DOWN
arrow” to set the cold-water temperature. Cold water setting options are 7°C, 11°C, and 15°C, which will be
indicated by the icons on the display screen. After setting the temperature, press again to save the setting.
(If there is no activity for 20 seconds in setting mode, last state is automatically saved).
3. When user selects 15°C, two small bars indication will be displayed on the LCD screen.
When user selects 11°C, two medium bars indication will be displayed on the LCD screen.
When user selects 7°C, two tall bars indication will be displayed on the LCD screen.
When selecting the desired temperature icon will flash until the water temperature reaches the temperature
that was just selected, and the icon will then turn solid.
Quick Heating RE HEAT
Press the “Quick Heating” button to activate quick heating. The word “Quick Heating” will appear on the LCD screen.
The icon will flash until the water temperature reaches 96 degrees and will remain solid. Pressing the “Quick Heating”
button again during quick heating will cancel the quick heating operation.
Half/Full Tank Function
The device setting when powered on is half tank and the icon will appear on the LCD screen. When the
“Half/Full Tank” button is pressed, the icon will appear on the LCD screen, meaning full hot water tank, pressing
the “Half/Full Tank” button again to set half tank and the icon will appear on the LCD screen meaning half hot
water tank.
HALF TANK
FULL TANK
HALF TANK

Sabbath Mode
1. Switch on the Sabbath switch located at the top left side of the device, now the device enters Sabbath Mode and the
icon will appear on the LCD screen. Hot and cold-water hold will take place only if the chilling and
heating switches are set on and “Chill” and “Heat” icons will appear on the LCD screen. If the heating and chilling
switches are set off, then temperature hold operation will not take place and no indication icon will appear on the
LCD screen.
2. In Sabbath Mode, water supply to the hot water tank is shut off and as long as the device is in Sabbath Mode no
water will enter. The main heating body will not be activated but only the secondary heating body for temperature
hold will be activated. In chilling there will be mode continuation, the compressor will operate 5 minutes to chill the
water and will stop working for 30 minutes, repeatedly. In Sabbath Mode pressing any button will not activate any
function and no tones will be heard.
3. In Sabbath Mode the cold-water sensor, hot water sensor, and float will not work.
4. Sabbath Mode will only be cancelled manually by pressing the Sabbath switch, any disconnection and resupply of
electrical power will leave the device at the Mode that was defined in advance.
5. During transition from Sabbath Mode to Normal Mode, time settings will be saved in memory unless the device has
been unplugged from electricity and then the time settings will reset.
6. To enter Normal Mode, press the mode transition switch.
Timing Function
1. After connecting the device to an electrical power supply, at the default setting the device is without timing
function. In order to set timing for the water dispenser you should set the local time and then set 4 time groups for
the water dispenser. After setting the time groups the timing function will come up automatically.
2. Press the “TIME” button and then press the “SET” button, “SET CLOCK” indication will appear on the LCD screen (this
indication means that the water device is now in time setting mode), the 2 left digits “88” will flash. Press the arrow
buttons “UP, DOWN” in order to set the hour. Hour range is between 0-23 hours. After setting the hour, press the
“SET” button again, now the 2 right digits “88” will flash and to set them press the arrow buttons “UP, DOWN” in
order to set the minutes. After setting the minutes, press the “TIME” button. The minutes range is 0-59.
3. Now the first “8” digit will turn to the digit “1” and in this state the water dispenser start time will be set. To set the
start time of its operation repeat steps 1 and 2.
4. Pressing the “TIME” button will cause the digit “8” to turn to the digit “2” and now the device operation end time
will be set. To set the end time of its operation repeat steps 1 and 2.
5. When pressing the “TIME” button again the digit “8” will turn to the digit “3” and the operation of device activation
timing as in step 3 will be performed.
6. When pressing the “TIME” button again the digit “8” will turn to the digit “4” and the operation of device
deactivation timing as in step 4 will be performed.
7. Finally, press the “TIME” button to save the settings of the 5 time groups. The indication “SET CLOCK” will not
extinguish, press the “TIME” button and “SET” button in order to toggle through the time groups. (If there is no
activity for 20 seconds in setting mode, last state is automatically saved).
8. When the timing function is activated, and the device is in OFF timing state, screen lighting does not work, and the
screen only displays the clock and all functions will be unavailable for activation. When the device is in ON timing
state all functions will be available.
9. Restarting the water dispenser –press the “TIME” button and hold for 10 seconds, now the water dispenser will
auto-restart. The time settings and temperature settings will be set to the default.
Table of contents