Krautzberger 200-0157 User manual

Operating instructions
Pressure container, 50 litre capacity,
for operating pressures of 2.5 and 6 bar
Doc-315 Rev. 0

Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc Order-No. 200-0157
CONTENTS
1USE FOR INTENDED PURPOSE ......2
2GENERAL SAFETY NOTES...............2
3INSPECTION BY QUALIFIED
EXPERTS IN ACCORDANCE WITH THE
“AD” INFO SHEETS ...................................3
4BASIC DESIGN...................................4
5INSTALLATION, MOUNTING OF THE
CONTAINER ..............................................5
5.1 Connections...........................................5
5.2 Filling....................................................5
6REGULAR CHECKS, MAINTENANCE
6
7CLEANING, DISPOSAL......................6
8WEARING PARTS, SPARE PARTS...7
9TROUBLESHOOTING ........................7
10 TECHNICAL DATA..........................7
1 Use for intended pur-
pose
Krautzberger material pressure containers
are containers with detachable covers in
which compressed air can be used to pres-
surise liquid and low-viscosity materials.
The pressurised material can then be
routed via suitable hoses and pipes to ex-
traction points (e.g. spray guns or similar).
Pressure containers are primarily used in
the painting and coating sector.
The temperature of the coating medium
may not be below -10°C or above +50°C.
Corrosive or highly abrasive materials may
only be used following consultation with
Krautzberger.
Krautzberger pressure containers are
equipped as standard with a material outlet
with shutoff device, compressed air connec-
tion fitting with overpressure valve, and a
pressure gauge for pressure indication.
Pressure containers may be fitted with stir-
rers, level gauges, filling devices and other
accessories.
Krautzberger 50-litre and 100-litre pressure
containers are designed for 10,000 stress
reversals (1 stress reversal (or load cycle)
is equivalent to a pressure fluctuation range
> 3bar).
When using hazardous substances:
When using hazardous substances,
note that the substance is released into
the atmosphere if the safety valve is ac-
tivated.
It is illegal to release certain hazardous
substances directly into the atmos-
phere, and some substances may not
be present at the workplace in inadmis-
sibly high concentrations. This means
that the safety valve must be of a de-
sign that permits connection to a pipe-
line, via which the hazardous sub-
stances can be routed to a treatment
system if necessary. Krautzberger
pressure containers can therefore be
equipped with a safety valve with con-
nection option.
2 General safety notes
Material pressure containers may
not be transported in pressurised
state!
The construction of pressure con-
tainers may not be altered!
Pressure containers may only be
operated within the operating pa-
rameters (pressure, temperature
etc.) specified on the rating plate!
The housing of the pressure con-
tainers is made of stainless steel
and may have galvanised or
enameled surfaces. The operator
must check the compatibility of
the materials with the coating
substances used. Please also re-
fer to the instructions of the
manufacturer of the coating sub-
stance.
2

Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc Order-No. 200-0157
3
Before opening a pressure con-
tainer, the compressed air feed
must always be shut off and the
container rendered pressureless
via the venting valve!
Stirring mechanisms must be
switched off and secured against
accidental switch-on!
Rooms in which hazardous substances
are stored or processed must have
adequate ventilation. It may be neces-
sary to install a ventilation system.
If the ventilation system fails, work
must be stopped immediately and the
stirrer switched off.
Always comply with the relevant na-
tional and regional regulations.
Please always read and observe
the safety and treatment instruc-
tions of the material manufacturer –
in particular instructions relating
to:
the wearing of protective
equipment during the use
of hazardous substances
the avoidance of harmful or
explosive environments
Do not store any flammable sub-
stances, empty coating substance con-
tainers or other materials that have
been in contact with the coating sub-
stance (paper, cloths etc.) in the con-
tainer or in the working zone.
Do not use halogenated detergents.
Chemical reactions may cause explo-
sive and caustic compounds!
Electrostatic charges during opera-
tion of the pressure container can
lead to electric shocks and spark
formation.
The pressure container must there-
fore be earthed!
Air lines, material pipes and con-
tainers, equipment and electrically
conductive surfaces in the working
zones must also be earthed.
In the working zone, avoid open flames
and red-hot components as well as
equipment, tools and parts that can
create ignitable sparks.
Hang up “No Smoking” signs in a 5-
metre radius of the container. Make fire
extinguishers available if these are not
already in place!
Components connected by the op-
erator (hoses and pipes, fittings,
extraction devices etc.) must be re-
liably able to withstand the loads to
be expected during operation of the
pressure container (pressure, tem-
perature, chemical and mechanical
influences).
Before each operating step, check
hoses and pipes for possible dam-
age and ensure that they are firmly
connected. Loose, pressurised
hoses may cause accidents due to
whiplash-like movement and the
uncontrolled discharge of fluids.
Comply with all national and regional
water protection regulations!
Comply with all national and regional
waste disposal regulations!

Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc Order-No. 200-0157
3 Basic design
2
3
9
4
5
6
11
1
8
10
7
1 Stirrer (optional)
2 “Maximum” level gauge (optional)
3 “Minimum” level gauge (optional)
4 Material extraction point
5 Pressure gauge
6 Compressed air connection
7 Level indicator (optional)
8 Ball cock for venting
9 Material return (optional)
10 Sound dampener or connection option
for waste air line
11 Safety valve
The material extraction point (4) can be located the bottom or routed through the container
cover via a riser pipe. The material extraction point may have more than one port for the con-
nection of more than one consumer. The air fitting can be equipped with connection options for
additional compressed air consumers – such as stirrers, handheld spray guns etc.
4

Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc Order-No. 200-0157
4 Installation, mounting of the container
Pressure containers must be installed in such a way that:
neither employees nor third parties are at risk
they are accessible for regular inspection
the rating plate is easily visible
the pressure container can be operated from a safe and stable position
they are protected against external mechanical influences
they are protected against unauthorised access
4.1 Connections
Connect the material pressure hose leading to your extraction point to the material out-
let (4)
The material outlet can be located the bottom or routed through the container cover via a
riser pipe. The material outlet may have more than one port for the connection of more
than one consumer.
Connect the compressed air feed to the air connection (6)
The compressed air supply must be dry and oil-free. Make the necessary provision for a
suitable shutoff device (ball cock).
The compressed air fitting can be equipped with more than one (if necessary adjustable)
outlet for the connection of additional consumers (spray gun, stirrer etc.).
Connect the waste air line to the safety valve
Connect the earthing device and earth all conductive components in the working zone
Check firmness of all connections!
4.2 Filling
Each time before you fill the container:
Shut off the compressed air feed
Vent the container via the ball cock (8) until the container is pressureless
Switch off stirrer – if present
Do not open the container cover until the container has been fully vented!
There is increased risk of fire when you open the cover! In the working zone, avoid open
flames and red-hot components as well as equipment, tools and parts that can create ignit-
able sparks!
When removing the cover, make sure that the stirrer blades do not knock against the con-
tainer wall, thus creating ignitable sparks.
Loosen star-grip screws/clamp fasteners
Remove cover
5

Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc Order-No. 200-0157
Clean pressure container using a suitable detergent when necessary
Fill pressure container. Do not exceed the maximum filling level (see Technical data)!
Close cover, tighten star-grip screws/clamp fasteners
Open compressed air feed
5 Regular checks, maintenance
Check the proper functioning of the safety
valve every time before you begin operat-
ing the system! To test the valve function,
turn the knurled screw of the safety valve
to the left. If the valve does not blow off,
the pressure container must not be oper-
ated until a new safety component has
been fitted!
Check the air and material lines and their
connections for seal-tightness and firm
seat every time before you begin operating
the system.
Before opening the pressure container,
check the cover gasket for soiling, wear
and damage.
Before opening a pressure container for all maintenance., servicing and cleaning
work on the open container, the air feed must always be shut off and the container
rendered pressureless!
Stirring mechanisms must be switched off and secured against accidental switch-
on!
6 Cleaning, disposal
Clean the pressure container after use thoroughly using a suitable detergent. Ensure that the
sealing surfaces between container and container cover are clean.
Dispose of materials accumulating during cleaning (cloths etc.) through the appropriate chan-
nels. Comply with the regulations of the local waste disposal authorities.
Comply with the safety instructions of the detergent manufacturer. Detergents may
be harmful to your health and be easily flammable!
Ensure that the detergent is compatible with the container materials!
6

Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc Order-No. 200-0157
7 Wearing parts, spare parts
Gaskets are subject to material fatigue and natural wear. Defective gaskets are noticeable from
the leakage of air or coating substance on fittings or connections. Gaskets may be made of
NBR, PE, EPDM or Viton.
When changing gaskets, check compatibility with the coating substance used.
Cover gasket for 50-litre and 100-litre container
Material Article number
NBR 5840-010-0220
PE 5840-010-0221
EPDM 5840-010-0222
Viton 5840-010-0223
8 Troubleshooting
Problem Cause Remedy
Leakage between container
flange and cover
Container flange, cover gas-
ket soiled or porous
Clean or replace
Leakage at compressed air fit-
ting
Gaskets defective Replace gaskets
Leakage at stirrer mounting Gasket defective Replace gaskets
Leakage at material outlet Gasket defective Replace gaskets
Material pressure cannot be ad-
justed
Material pressure regulator
defective
Replace
9 Technical data
50-litre type 100-litre type
Compressed air feed dry, oil-free, filtered
2.5-6bar
dry, oil-free, filtered
2.5-6bar
Max. filling volume 58litres 126 litres
Ambient temperature -10 to +50°C -10 to +50°C
Temperature – coating material -10 to +50°C -10 to +50°C
Test pressure/Date 3.6bar/8.6bar 3.6bar/8.6bar
Setting pressure of over-
pressure valve
customer-specific customer-specific
Weight (empty) 63-72kg 88-97kg
Dimensions max. 1025x495mm max. 1300x625mm
Mains voltage – electric stirrer 230V/50Hz 230V/50Hz
7

Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc Order-No. 200-0157
10 Dimensions
Je nach Rührwerk
760~Ø
310~
470~
550~
390~Ø
765~
650~
8

Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc Order-No. 200-0157
EG-Konformitätserklärung
EC-Declaration of conformity
gemäß Anhang VII der EG – Druckgeräterichtlinie 97/23/EG
as defined by Pressure Equipment Directive 97/23/EC Annex VII
Krautzberger GmbH
Stockbornstraße 13
65343 Eltville am Rhein
HIERMIT ERKLÄREN WIR, DASS FOLGENDES PRODUKT
HEREWITH WE DECLARE, THAT THE PRESSURE EQUIPMENT
Bezeichnung
Type
Materialdruckbehälter MDH mit 50l Inhalt;
2,5 - 6bar Betriebsdruck
Artikel-Nummer
Serial-no.
200-0157
Funktion
Function
Druckluft betriebener Materialdruckbehälter zur Druckbeaufschlagung
von flüssigen und niederviskosen Medien
IN DER GELIEFERTEN AUSFÜHRUNG FOLGENDEN BESTIMMUNGEN ENTSPRICHT:
CORRESPONDS TO FOLLOWING PERTINENT REGULATIONS IN THE DELIVERED IMPLEMENTATION
EG–Druckgeräterichtlinie 97/23/EWG, EG-Niederspannungs-Richtlinie 73/23/EWG (nur bei elektri-
schen Anbauteilen), EG-EMV-Richtlinie 93/68/EWG (nur bei elektrischen Anbauteilen), EG-
Maschinenrichtlinie 98/37 EG (bei Elektro- und Druckluftrührwerken)
Folgende harmonisierte EU-Normen wurden angewendet:
APPLIED HARMONIZED STANDARDS, IN PARTICULAR:
DIN EN 1050 (bei Rührwerken)
DIN EN 292-1/2 (bei Rührwerken)
DIN prEN 12757-1 (bei Rührwerken)
DIN EN 60204-1 (bei Elektrorührwerken)
Folgende nationale Normen wurden angewendet:
APPLIED STANDARDS AND TECHNICAL SPECIFICATIONS, IN PARTICULAR
AD 2000 Merkblätter
ANGEWANDTES KONFORMITÄTSBEWERTUNGS-
VERFAHREN:
Modul B+C1
Benannte Stelle gem. Artikel 12 Druckgeräte-
Richtlinie:
ENGAGED NOTIFIED BODIES:
TÜV Technische Überwachung Hessen
GmbH
Rüdesheimer Strasse 119
64285 Darmstadt
EG-BAUMUSTERPRÜFBESCHEINIGUNG NR.:
EC-TYPE EXAMINATION CERTIFICATE NO.
482 / 02
Datum: i.A.
Angaben zum Unterzeichner: M. Stoffels,
Leiter Konstruktion
Fluide Gru
pp
e 1
9

Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc Order-No. 200-0157
11 Inspection by qualified experts
Pressure containers must be checked on a regular basis by qualified experts. The in-
spection intervals depend on operational experience, the substances used, and the
outcome of previous inspections.
However, the following periods may not be exceeded:
Internal inspection: every 5 years
Pressure testing: every 10 years
External inspection: every 2 years
Internal and external inspection must be performed after 5,000 stress reversals. Re-
cord each startup and rundown of the container with a pressure fluctuation range >
3bar (equivalent to one stress reversal).
Acceptance test
:
.....................................
inspector
at:
.....................................
date
sign:
..................................................................
10

Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc Order-No. 200-0157
11
first periodic inspection
next periodic inspection
Installation test

Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc Order-No. 200-0157
next periodic inspection
next periodic inspection
12

Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc Order-No. 200-0157
next periodic inspection
next periodic inspection
13

Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc Order-No. 200-0157
next periodic inspection
next periodic inspection
14

Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc Order-No. 200-0157
next periodic inspection
next periodic inspection
15
Table of contents
Other Krautzberger Industrial Equipment manuals
Popular Industrial Equipment manuals by other brands

ARCURE
ARCURE BLAXTAIR 3 installation instructions

Deitz
Deitz PHARMAFILL CS10 Operation manual

Keysight
Keysight N5225-60110 Installation note

SCHUNK
SCHUNK ERT 100 Translation of original operating manual

ABB
ABB HT609447 Operation manual

PCB Piezotronics
PCB Piezotronics 352A24/NC Installation and operating manual

Carbex
Carbex i-BRUSH 2.0 installation manual

ABB
ABB TPS44-H33 Operation instructions

TNA
TNA TX7302 Installation and operation manual

Bastian Solutions
Bastian Solutions RZPAC Installation and maintenance manual

PCB Piezotronics
PCB Piezotronics 354C02 Installation and operating manual

Reflex
Reflex Reflexomat Original operating manual