  9. KREYER Chilly User manual

KREYER Chilly User manual

Picture guide
Start-up of chillers type
Chilly
230V / single phase
Important notes:
The following picture guide is additional information to the official instruction manual and does
not replace it The instructions in the manual are to be considered before this document
Electrical and water installation and the start-up should be done by qualified personnel
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 2of 18) v.11-2015
Dear Chilly user – Brewer, winemaker, hobby user!
Congratulations on your new CHILLY unit !!
The following guide includes pictures to show you the step-for-step installation
and start-up of your new Chilly to help you get started fast and easy.
Pic.1: Your new CHILLY would be delivered secured on a pallet with protective foil and safety bands, eventually
in carton packaging.
Please check at arriving on possible transport damages and claim these immediately to the transporter.
If you are not sure please unpack the unit together with the transporter.
Transport damages cannot enforcement later!!
Correct place of installation:
In a well aired room.
If set outside, the unit should be under an awning or in a shed providing protection from the elements
(sunshine, rain, snow) and well aired.
The unit operates between the ambient temperatures:
Min. +10°C / 50°F
Max. + 42°C / 107°F
Distance / placement:
Free space in front of the cool air intake min. 0,5 meter / 2 feet
Free space in front of the hot air outlet min. 1,0 meter / 3,5 feet
For exact installation conditions, please refer to the manual.
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 3of 18) v.11-2015
Pic.2: When unpacking the Chilly, you will find its official
Instruction Manual
. This Manual pertains to your
specific unit by means of its Serial Number. The electrical diagram in this manual pertains to your unit.
Unit Serial Number appears on the name plate attached to it (8 digit number).
Pic. 3: View inside of the open tank – the heat-exchanger (evaporator) in spiral type is visible
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 4of 18) v.11-2015
Pic. 4: Fill the tank with clear water
Pic. 5: Add ‘food-safe’ grade glycol (anti-frost protection) to the water. The concentration of the Glycol in the total
quantity of water in your system depends on the water temperatures you want to set your Chilly to produce, and
the instructions from the Glycol manufacturer. Typically, you need to have about 25% - 30% of Glycol part in the
total quantity of water in your system. (Necessary for low temp Chillys, if ambient temperature can reach negative
temperature or in case of cooling below +8°C is needed)
Pic. 6: Controlling the level of filled water/glycol-mix in the sight glass - it should always be between MIN
(minimum) and MAX (maximum), also when the unit is in full operation.
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 5of 18) v.11-2015
If the water level went down after you started using the unit and water is circulating in your tanks – top up the
water and make sure to add Glycol in the right quantity as well!
Pic. 7 + 8: Connection of the systems water pipes/hoses to the chiller. At this point the valves are closed and
pointing upwards (see arrow direction).
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 6of 18) v.11-2015
Pic. 9: Bleeding of the pump (letting out air from the pump) – disconnect the tube/hose of the chiller
water outlet and open the outlet valve . At first the water will flow out in spurts. Keep the valve open
until the water comes out in a constant flow. This tells you that all air has been pushed out of the pump
by the water. Close the valve again and top up the water in the tank if necessary. Remember your
Glycol!
Attention:
Please check the pressure capacity of the unit pump. Please ensure that all
components in your water system are compatible with the maximum pump pressure. If
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 7of 18) v.11-2015
necessary, use pressure-reducer elements (e.g. bypass-valve) in your water system. Pump
capacity and further information are inside the unit manual.
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 8of 18) v.11-2015
Pic. 10: Reconnect the tube/hose to the chillers outlet. Then open both valves
(The valves are open when they are parallel to the tube, see arrows).
Optional: Overflow protection kit
he unit CHILLY is working as an open water system. Water users (e.g. tanks) should be installed on
the same level as the chiller or below to avoid an overflow of the chillers buffer tank when the
unit/pump is off.
If this isn’t possible you should install an overflow protection kit (consisting of a solenoid valve, a
solenoid connection cable and a non-return valve – available from WTG / KREYER). For the right
voltage of the solenoid valve respect absolutely the available control voltage of the chiller –> check
inside the electrical diagram appearing at the end of the instruction manual.
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 9of 18) v.11-2015
Install the non-return valve in the outlet pipe/flow line (for the right fitting position respect the flow
direction indicated by an arrow on the non-return valve) and the solenoid valve in the inlet
pipe/return line of your chiller (see picture in the example below
Insert the solenoid connection cable in one of the free cable inlets at the side of the chiller (see green
arrows -> remove one of the pre-cut openings + install a screwed cable gland) and lead it through to
the control cabinet:
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 10 of 18) v.11-2015
Check the electrical diagram of the chiller appearing at the end of the instruction manual where to
connect the cable of the solenoid valve (in this example here the contact inside the control cabinet is
X2 -> clips 5, 6 and 7=earth). It doesn’t matter whether you connect the brown or the blue cable to
clip 5 or 6:
Please check and compare volage on name plate with your local voltage – if not correlating
please contact your supplier!
- End of the optional overflow protection kit -
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 11 of 18) v.11-2015
Pic. 11 + 12: Take the plug and connect it to your power supply.
Note: Chilly units are used in many countries. It can happen that your unit comes with a plug
which is not the standard in your country. You may need to replace the plug on the unit to your
local type.
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 12 of 18) v.11-2015
NOTE:
Please close the lid of the Chilly unit when you have finished the installation
The unit should operate when the lid is closed for proper transfer of cold air from the fan
into the condenser
By open lid, the air sucked into the unit is drawn from the warm ambience all around the unit, and not only through
the fan which cools it properly on the way to the condenser. This may cause in some cases a stop due high-
pressure, and may reduce significantly the cooling capacity of the unit, so low temperatures may not be reached
as set.
Keep lid closed while the unit is in operation!
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 13 of 18) v.11-2015
Pic. 13 + 14: Switching on the unit by turning the main switch to ON (dashed line appears in the display)
Pic.15 (left): Adjusting the Set-Temperature ( this picture is in Celsius degrees, in the next page and in the official
manual you will find how to change your unit to show F° Fahrenheit degrees)
Pic. 16 (right): Chiller displaying the actual temperature
Operating mode:
he Chilly
displaying the
actual
temperature
(11°C)
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 14 of 18) v.11-2015
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 15 of 18) v.11-2015
Instructions to adjust the regulator PJ Easy
Parameter to change temperature from °C to °F (regulator PJ Easy):
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 16 of 18) v.11-2015
Optional: regulator ELIWELL ST 120
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 17 of 18) v.11-2015
Parameter to change temperature from °C to °F (regulator ELIWELL ST120):
-Press and hold for longer than 5 seconds
-Search “PA2” by pressing or and confirm with
-ype “22” by pressing and confirm with
-Search “diS” by pressing or and confirm with
-Search “dro” by pressing or and confirm with
-Select the unit of measurement used when displaying the temperature recorded by the
probes with or : value 0 = °C, value 1 = °F and confirm with
-Press to return to the standard operation menu
IMPORTANT NOTE: switching between °C and °F DOES NOT modify the SEt, diF values etc
(e g Setpoint=10°C becomes 10°F)
Optional: Differential pressure switch
Installed in most of the CHILLYs in the USA
When the pump pressure is correctly set adapted to your tank installation - the integral pump inside
the cooling unit would switch-off when all tank valves are closed and there is temporarily no
requirement for cooling/heating -> this needs to be adjusted.
o adjust take a screw driver, open the casing of the differential pressure switch (installed nearby the
pump) and adjust it corresponding to the description in the instruction manual. Afterwards close the
casing of the pressure switch and close the open cover panel of the unit
_________________________________________________________________________________________
Kreyer – Picture guide to installation and start-up Chilly (page 18 of 18) v.11-2015
Your Chilly is now ready to cool your tanks!
If you have Chilly 400V / 3 phase – (Chilly 350, Chilly 450) –
Please check the unit manual for the correct electrical connection
In case of technical questions or problems please always indicate the machine
type and its serial number - see green box in the picture above! You will find
this information on the type plate mounted on the outer side of each
machine
It is recommended to save this manual and the operation manual of your unit
within reach and to keep another copy in your office as back-up
For questions and assistance please contact your local Chilly provider or
contact us at KREYER Germany:

Other manuals for Chilly

1

Other KREYER Chiller manuals

KREYER MCK Series User manual

KREYER

KREYER MCK Series User manual

KREYER Chilly User manual

KREYER

KREYER Chilly User manual

Popular Chiller manuals by other brands

Zanussi ZANUSSI easyChill 110005 Specifications

Zanussi

Zanussi ZANUSSI easyChill 110005 Specifications

Trane RTHD Troubleshooting

Trane

Trane RTHD Troubleshooting

York YZ Wiring diagrams

York

York YZ Wiring diagrams

Trane RTAA installation instructions

Trane

Trane RTAA installation instructions

Fujitsu AIRSTAGE ARUH72TLAV2 installation manual

Fujitsu

Fujitsu AIRSTAGE ARUH72TLAV2 installation manual

FTS CHARPYCOOL Operator's manual

FTS

FTS CHARPYCOOL Operator's manual

aquatherm AT-5000 Installation, use & care manual

aquatherm

aquatherm AT-5000 Installation, use & care manual

Daikin SkyAir RZF-A Series Service manual

Daikin

Daikin SkyAir RZF-A Series Service manual

Carrier 16LJ-01 Operation manual

Carrier

Carrier 16LJ-01 Operation manual

Elkay HRC2-5-1C installation instructions

Elkay

Elkay HRC2-5-1C installation instructions

Daikin EWYQ007ACV3P Operation manual

Daikin

Daikin EWYQ007ACV3P Operation manual

Modena UC Series manual

Modena

Modena UC Series manual

MAXA i-32V504 manual

MAXA

MAXA i-32V504 manual

NANO Precision NPC 015 Service manual

NANO

NANO Precision NPC 015 Service manual

AERMEC NYB 500 RP Wiring diagram

AERMEC

AERMEC NYB 500 RP Wiring diagram

Huber Unichiller 400T Operation manual

Huber

Huber Unichiller 400T Operation manual

AERMEC CR Series Technical and Installation Booklet

AERMEC

AERMEC CR Series Technical and Installation Booklet

Trane CVHH CenTraVac Installation, operation and maintenance

Trane

Trane CVHH CenTraVac Installation, operation and maintenance

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.