KROHNE SMARTPAT COND 7200 User manual

Digital conductivity sensor for the pharmaceutical, food
and beverage industries
Electronic Revision:
ER 1.0.0_
(SW.REV 1.0.x)
SMARTPAT COND 7200
SMARTPAT COND 7200SMARTPAT COND 7200
SMARTPAT COND 7200 Handbook
HandbookHandbook
Handbook
© KROHNE 02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en

All rights reserved. It is prohibited to reproduce this documentation, or any part thereof, without
the prior written authorisation of KROHNE Messtechnik GmbH.
Subject to change without notice.
2
SM
www.krohne.com 02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
Copyright 2017 by
KROHNE Messtechnik GmbH - Ludwig-Krohne-Str. 5 - 47058 Duisburg (Germany)
:
IMPRINT
:::::::::::::::::::::::::::::::::::::::

CONTENTS
3
www.krohne.com02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
SMARTPAT COND 7200
1 Safety instructions 5
1.1 Intended use ..................................................................................................................... 5
1.2 Certifications .................................................................................................................... 5
1.3 Safety instructions from the manufacturer ..................................................................... 6
1.3.1 Copyright and data protection ................................................................................................ 6
1.3.2 Disclaimer ............................................................................................................................... 6
1.3.3 Product liability and warranty ................................................................................................ 7
1.3.4 Information concerning the documentation........................................................................... 7
1.3.5 Warnings and symbols used................................................................................................... 8
1.4 Safety instructions for the operator................................................................................. 8
2 Device description 9
2.1 Scope of delivery............................................................................................................... 9
2.2 Device description .......................................................................................................... 10
2.3 Nameplate ...................................................................................................................... 10
3 Installation 11
3.1 General notes on installation ......................................................................................... 11
3.2 Storage and transport .................................................................................................... 11
3.3 Pre-installation requirements ....................................................................................... 12
3.4 Installation procedure .................................................................................................... 13
4 Electrical connections 14
4.1 Safety instructions.......................................................................................................... 14
4.2 Power supply .................................................................................................................. 14
4.3 Grounding and equipotential bonding............................................................................ 15
4.4 Connecting the cable to the sensor ............................................................................... 15
4.5 Connecting the sensor cable.......................................................................................... 15
4.6 Connection diagram ....................................................................................................... 16
4.7 Installing the sensor....................................................................................................... 18
4.7.1 General installation instructions .......................................................................................... 18
4.7.2 Installation recommendation ............................................................................................... 19
5 Operation 21
5.1 Configuration .................................................................................................................. 21
5.2 Calibration ...................................................................................................................... 21
5.2.1 Calibration with PACTware
TM........................................................................................................................ 22
5.2.2 Calibration with HART
®
Handheld 475 FIELD COMMUNICATOR ........................................ 24
5.3 Troubleshooting.............................................................................................................. 26
5.4 Status messages and diagnostic information................................................................ 27

CONTENTS
4
www.krohne.com 02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
SMARTPAT COND 7200
6 Service 28
6.1 Maintenance ................................................................................................................... 28
6.1.1 Cleaning ................................................................................................................................ 28
6.2 Availability of services .................................................................................................... 28
6.3 Returning the device to the manufacturer..................................................................... 28
6.3.1 General information.............................................................................................................. 28
6.3.2 Form (for copying) to accompany a returned device............................................................ 29
6.4 Disposal .......................................................................................................................... 29
7 Technical data 30
7.1 Measuring principle........................................................................................................30
7.1.1 Conductivity measurement................................................................................................... 30
7.2 Technical data................................................................................................................. 31
7.3 Dimensions ..................................................................................................................... 33
7.4 Temperature derating .................................................................................................... 35
8 Description of HART interface 36
8.1 General description ........................................................................................................36
8.2 Software history ............................................................................................................. 36
8.3 Connection variants........................................................................................................37
8.3.1 Point-to-Point connection - analogue / digital mode........................................................... 38
8.4 Inputs/outputs and HART®dynamic variables and device variables............................ 39
8.5 Field Communicator 475 (FC 475).................................................................................. 39
8.5.1 Installation ............................................................................................................................ 39
8.6 Field Device Tool / Device Type Manager (FDT/DTM).................................................... 40
8.6.1 Installation ............................................................................................................................ 40
8.7 Overview Basic-DD menu tree (for Field Communicator 475) ...................................... 40
8.8 Basic-DD menu tree (details for settings) ..................................................................... 41

SAFETY INSTRUCTIONS
1
5
SMARTPAT COND 7200
www.krohne.com02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
1.1 Intended use
The intended use of the sensor SMARTPAT COND 7200 is the measurement of conductivity in
conductive liquids.
1.2 Certifications
The device meets the essential requirements of the EU directives. The CE marking indicates the
conformity of the product with the union legislation applying to the product and providing for CE
marking.
For full information of the EU directives and standards and the approved certifications, please
refer to the EU declaration on the KROHNE website
Other approvals and standard
•NAMUR recommendation NE 21
The manufacturer certifies successful testing of the product by applying the CE marking.
CAUTION!
Responsibility for the use of the measuring devices with regard to suitability, intended use and
corrosion resistance of the used materials against the measured fluid lies solely with the
operator.
INFORMATION!
This device is a Group 1, Class A device as specified within CISPR11:2009. It is intended for use in
industrial environment. There may be potential difficulties in ensuring electromagnetic
compatibility in other environments, due to conducted as well as radiated disturbances.
INFORMATION!
The manufacturer is not liable for any damage resulting from improper use or use for other than
the intended purpose.
CE marking

1
SAFETY INSTRUCTIONS
6
SMARTPAT COND 7200
www.krohne.com 02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
1.3 Safety instructions from the manufacturer
1.3.1 Copyright and data protection
The contents of this document have been created with great care. Nevertheless, we provide no
guarantee that the contents are correct, complete or up-to-date.
The contents and works in this document are subject to copyright. Contributions from third
parties are identified as such. Reproduction, processing, dissemination and any type of use
beyond what is permitted under copyright requires written authorisation from the respective
author and/or the manufacturer.
The manufacturer tries always to observe the copyrights of others, and to draw on works created
in-house or works in the public domain.
The collection of personal data (such as names, street addresses or e-mail addresses) in the
manufacturer's documents is always on a voluntary basis whenever possible. Whenever
feasible, it is always possible to make use of the offerings and services without providing any
personal data.
We draw your attention to the fact that data transmission over the Internet (e.g. when
communicating by e-mail) may involve gaps in security. It is not possible to protect such data
completely against access by third parties.
We hereby expressly prohibit the use of the contact data published as part of our duty to publish
an imprint for the purpose of sending us any advertising or informational materials that we have
not expressly requested.
1.3.2 Disclaimer
The manufacturer will not be liable for any damage of any kind by using its product, including,
but not limited to direct, indirect or incidental and consequential damages.
This disclaimer does not apply in case the manufacturer has acted on purpose or with gross
negligence. In the event any applicable law does not allow such limitations on implied warranties
or the exclusion of limitation of certain damages, you may, if such law applies to you, not be
subject to some or all of the above disclaimer, exclusions or limitations.
Any product purchased from the manufacturer is warranted in accordance with the relevant
product documentation and our Terms and Conditions of Sale.
The manufacturer reserves the right to alter the content of its documents, including this
disclaimer in any way, at any time, for any reason, without prior notification, and will not be liable
in any way for possible consequences of such changes.

SAFETY INSTRUCTIONS
1
7
SMARTPAT COND 7200
www.krohne.com02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
1.3.3 Product liability and warranty
The operator shall bear responsibility for the suitability of the device for the specific purpose.
The manufacturer accepts no liability for the consequences of misuse by the operator. Improper
installation or operation of the devices (systems) will cause the warranty to be void. The
respective "Standard Terms and Conditions" which form the basis for the sales contract shall
also apply.
1.3.4 Information concerning the documentation
To prevent any injury to the user or damage to the device it is essential that you read the
information in this document and observe applicable national standards, safety requirements
and accident prevention regulations.
If this document is not in your native language and if you have any problems understanding the
text, we advise you to contact your local office for assistance. The manufacturer can not accept
responsibility for any damage or injury caused by misunderstanding of the information in this
document.
This document is provided to help you establish operating conditions, which will permit safe and
efficient use of this device. Special considerations and precautions are also described in the
document, which appear in the form of icons as shown below.

1
SAFETY INSTRUCTIONS
8
SMARTPAT COND 7200
www.krohne.com 02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
1.3.5 Warnings and symbols used
Safety warnings are indicated by the following symbols.
• HANDLING
HANDLINGHANDLING
HANDLING
This symbol designates all instructions for actions to be carried out by the operator in the
specified sequence.
iRESULT
RESULTRESULT
RESULT
This symbol refers to all important consequences of the previous actions.
1.4 Safety instructions for the operator
DANGER!
This warning refers to the immediate danger when working with electricity.
DANGER!
This warning refers to the immediate danger of burns caused by heat or hot surfaces.
DANGER!
This warning refers to the immediate danger when using this device in a hazardous atmosphere.
DANGER!
These warnings must be observed without fail. Even partial disregard of this warning can lead to
serious health problems and even death. There is also the risk of seriously damaging the device
or parts of the operator's plant.
WARNING!
Disregarding this safety warning, even if only in part, poses the risk of serious health problems.
There is also the risk of damaging the device or parts of the operator's plant.
CAUTION!
Disregarding these instructions can result in damage to the device or to parts of the operator's
plant.
INFORMATION!
These instructions contain important information for the handling of the device.
LEGAL NOTICE!
This note contains information on statutory directives and standards.
WARNING!
In general, devices from the manufacturer may only be installed, commissioned, operated and
maintained by properly trained and authorized personnel.
This document is provided to help you establish operating conditions, which will permit safe and
efficient use of this device.

DEVICE DESCRIPTION
2
9
SMARTPAT COND 7200
www.krohne.com02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
2.1 Scope of delivery
Optional accessories
•Cable VP2-S (cable with shield in various lengths)
•SD 200 W/R –Wall or rack mount indicator
•OPTIBRIDGE / SMARTBRIDGE –USB interface cable
•SJB 200 W-Ex –Junction box
Consumables/Spare parts available
•Various conductivity standard solutions for sensor calibration
INFORMATION!
Inspect the packaging carefully for damages or signs of rough handling. Report damage to the
carrier and to the local office of the manufacturer.
INFORMATION!
Do a check of the packing list to make sure that you have all the elements given in the order.
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Figure 2-1: Standard scope of delivery
1 Ordered sensor with the ordered process connection
2 Documentation, including calibration certificate
3 CD with sensor software
INFORMATION!
For further information contact your local sales office.

2
DEVICE DESCRIPTION
10
SMARTPAT COND 7200
www.krohne.com 02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
2.2 Device description
2.3 Nameplate
The sensor type is specified on the label of the sensor package and on the sensor itself.
Figure 2-2: Construction of the sensor
1 VP2 connector
2 M28 x 1.5 thread for process connection
Varivent DN 40...125, Clamp DN 25/32/40 (1...1.5" / Ø 50.5 mm) or Clamp DN 50 (2" / Ø 64 mm) adapter
3 Electrodes: stainless steel 1.4435 / 316L
Figure 2-3: Example for a nameplate on the sensor body
1 Manufacturer
2 Device name
3 Cell constant / Electronic Revision version
4 TAG number (optional)
5 Order code
6 Serial number
7 Manufacturing date / Ingress protection
8 Electronic - Electric device waste marking /
Observe the operation and installation instruction / Approvals
ER 1.0.0
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.

INSTALLATION
3
11
SMARTPAT COND 7200
www.krohne.com02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
3.1 General notes on installation
3.2 Storage and transport
DANGER!
For devices used in hazardous areas, additional safety notes apply; please refer to the Ex
documentation.
DANGER!
All work on the electrical connections may only be carried out with the power disconnected.
DANGER!
Observe the national regulations for electrical installations!
WARNING!
During installation of the device make sure that you use ESD (electrostatic discharge) protection
equipment.
WARNING!
Observe without fail the local occupational health and safety regulations. Any work done on the
electrical components of the measuring device may only be carried out by properly trained
specialists.
INFORMATION!
Inspect the packaging carefully for damages or signs of rough handling. Report damage to the
carrier and to the local office of the manufacturer.
INFORMATION!
Do a check of the packing list to make sure that you have all the elements given in the order.
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
CAUTION!
Do not make any mechanical modifications to the sensor (electrodes shortened, drilled, bent or
scratched). This can result in the loss of proper functionality, as well as the rights under the
device warranty.
•
Store and transport the device in a dry, dust-free environment.
•
Store and transport the device in an environment with a temperature between -40...+85
°
C /
-40...+185
°
F.
•
The original packing is designed to protect the equipment. It has to be used if the device is
transported or sent back to the manufacturer including the sensor transportation packing, to
prevent damage of the sensor.

3
INSTALLATION
12
SMARTPAT COND 7200
www.krohne.com 02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
3.3 Pre-installation requirements
The required steps are explained in the following sections.
Unpacking the sensor
• Remove by gently twisting and pulling the protective cap from the sensor 1.
• Lay the sensor on a soft ESD mat or soft paper tissue 2.
• Leave the protection cap of the VP connector, as long as the sensor is not connected to the
cable.
CAUTION!
•
Do not drop the device! Handle the device with care!
•
Never touch or scratch the electrodes of the sensor.
•
Store the sensor in its original packaging in a dry, dust-free location. Keep it away from dirt. If
necessary, clean it. See cleaning procedure on page 28
.
•
Do not make any mechanical modifications to the sensor (electrodes shortened, drilled, bent
or scratched). This can result in the loss of proper functionality, as well as the rights under
the device warranty.
•
The sensor must be suitable for the temperature, pressure and medium conditions which are
specified (including chemical resistance).
•
The device must not be heated by radiated heat (e.g. exposure to the sun) to a electronics
housing surface temperature above the maximum permissible ambient temperature. If it is
necessary to prevent damage from heat sources, a heat protection (e.g. sun shade) has to be
installed.
INFORMATION!
A sensor specific DTM software for usage with PACTware
TM
FDT is available. The DTM software
is free of charge and available from CD (scope of delivery) or can be downloaded from the
KROHNE website (Downloadcenter).
Figure 3-1: Unpacking the sensor

INSTALLATION
3
13
SMARTPAT COND 7200
www.krohne.com02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
3.4 Installation procedure
1 Screw the process connection adapter on the sensor.
2 Connect the sensor to the junction box or directly to the process control system.
3 Install the sensor into its final measuring location.
4 If necessary re-calibrate the cell constant for your process conditions. (To re-calibrate con-
nect either a HART field communicator or connect the sensor via OPTIBRIDGE / SMART-
BRIDGE to a PC.)
WARNING!
During installation of the device make sure that you use ESD (electrostatic discharge) protection
equipment.

4
ELECTRICAL CONNECTIONS
14
SMARTPAT COND 7200
www.krohne.com 02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
4.1 Safety instructions
4.2 Power supply
The sensor requires a minimum operating voltage of 15 VDC. The power supply is provided via
the 2-wire interface (4...20 mA).
During initialisation of the sensor following values appear in the display mode of the "Measuring
value":
The specification NaN (Not a Number) disappears after a few seconds once the initialisation of
the sensor is completed. Afterwards, the measured values appear.
DANGER!
For devices used in hazardous areas, additional safety notes apply; please refer to the Ex
documentation.
DANGER!
All work on the electrical connections may only be carried out with the power disconnected.
DANGER!
Observe the national regulations for electrical installations!
WARNING!
Observe without fail the local occupational health and safety regulations. Any work done on the
electrical components of the measuring device may only be carried out by properly trained
specialists.
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
CAUTION!
Do not use the integrate 250 Ohm HART
®
resistor of the SMARTMAC 200 W, when using an
Ex isolation amplifiers of third-party with integrated 250 Ohm HART
®
resistor.
Conductivity NaN
Resistance NaN
Temperature NaN
Loop current NaN

ELECTRICAL CONNECTIONS
4
15
SMARTPAT COND 7200
www.krohne.com02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
4.3 Grounding and equipotential bonding
Sensor type SMARTPAT COND 7200 must have a capacitive connection to ground.
SJB 200 W-Ex junction box offers the grounding possibility.
For further information refer to the SJB 200 W-Ex manual.
For connection of SMARTPAT sensor use only a VarioPin cable with shield wire, like the
cable VP2-S.
4.4 Connecting the cable to the sensor
Connecting the cable to the sensor
• Ensure that both cable and sensor connector are absolutely dry 1.
• Screw the cable connector 2on the sensor connector and tighten it by hand.
4.5 Connecting the sensor cable
WARNING!
During installation of the device make sure that you use ESD (electrostatic discharge) protection
equipment.
CAUTION!
Moisture on the sensor connector must be avoided! Moisture may cause a short-circuit and a
malfunction of the sensor!
If moisture has entered the connector dry it with air (e.g. hot air gun).
Figure 4-1: Connecting the cable to the sensor
DANGER!
All work on the electrical connections may only be carried out with the power disconnected.
INFORMATION!
The cable glands installed by the manufacturer are designed for a cable diameter of 8 mm...13 mm /
0.31"...0.51". If you are using cables with a larger diameter, you must replace the manufacturer's cable
glands with suitable ones. The operator is responsible for the correct sealing of cable glands.
Cable VP2-S
Transparent-black (inner coax shield) Ub+
White Ub-
Shield S

4
ELECTRICAL CONNECTIONS
16
SMARTPAT COND 7200
www.krohne.com 02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
4.6 Connection diagram
Connection to SJB 200 W-Ex
Figure 4-2: Example of a connection with a SJB 200 W-Ex junction box
1 SJB 200 W-Ex junction box with or without internal resistor used
2 Sensor with VP2-S cable
3 Display or other 4...20 mA loop powered device (e.g. data logger)
4 Control system without internal 250 Ωresistor connected to internal resistor of SJB 200 W-Ex
5 Control system with internal 250 Ωresistor connected to SJB 200 W-Ex without using internal resistor
SJB 200 W-Ex
with internal resistor
SJB 200 W-Ex
without internal resistor
SShield SShield
ASensor + ASensor +
BSensor - BSensor -
CDisplay + FLoop - w/o Display
DDisplay - HLoop +
ELoop - w/ Display
GLoop + [250Ω]

ELECTRICAL CONNECTIONS
4
17
SMARTPAT COND 7200
www.krohne.com02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
HART®interface within SJB 200 W
Figure 4-3: Example of a HART
®
handheld connection
1 Connection via crocodile clips
2 Only for Ex:
Only for Ex:Only for Ex:
Only for Ex: M12 connector for the HART
®
handheld connecting cable
Connection of SMARTMAC 200 W with a loop powered device via the optional
SJB 200 W-Ex junction box to a SMARTPAT sensor
Figure 4-4: Example of connecting the SMARTMAC 200 W to a control system without internal 250 Ωresistor and one
additional loop powered device
1 SMARTMAC 200 W
2 Sensor with VP2-S cable
3 Cable connection between SJB 200 W-Ex and SMARTMAC 200 W
4 Display or other 4...20 mA loop powered device (e.g. data logger)
5 Control system without internal 250 Ωresistor
6 SJB 200 W-Ex junction box
SMARTMAC 200 W
with internal resistor
SJB 200 W-Ex
without internal resistor
SShield A Sensor +
ASensor + BSensor -
BSensor - CDisplay +
FLoop - DDisplay-
GLoop + [250Ω] E Loop - w/ Display
HLoop +
-HART+
INFORMATION!
The SJB 200 W offers the opportunity to access the sensor via HART
®
hand held. For further
information refer to the manual of the SJB 200 W.

4
ELECTRICAL CONNECTIONS
18
SMARTPAT COND 7200
www.krohne.com 02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
4.7 Installing the sensor
4.7.1 General installation instructions
Connection with sensor and control system
Figure 4-5: SMARTMAC 200 W connection to a control system with internal 250 Ωresistor (left side). SMARTMAC 200 W
connection to a control system without internal 250 Ωresistor (right side).
1 SMARTMAC 200 W
2 Sensor with VP2-S cable
3 Control system with internal 250 Ωresistor
4 Control system without internal 250 Ωresistor
SMARTMAC 200 W
without internal resistor
SMARTMAC 200 W
with internal resistor
SShield SShield
ASensor + A Sensor +
BSensor - BSensor -
FLoop - FLoop -
HLoop + GLoop + [250Ω]
WARNING!
Ensure that the pipeline is without pressure before installing or removing a sensor!
INFORMATION!
During installation you should fix a shut-off valve in front of and behind the instrument so that
the sensor can be taken out in case of check.
INFORMATION!
To achieve reliable measuring results, the electrodes must always have full contact with the
measuring medium.
INFORMATION!
Basically any installation position is possible. However, ensure that sufficient medium flows
through and around the electrodes (the conductive electrodes must always be completely
surrounded by the medium). Structural measures must be taken to prevent flow interruption or
gas bubbles.

ELECTRICAL CONNECTIONS
4
19
SMARTPAT COND 7200
www.krohne.com02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
4.7.2 Installation recommendation
•Installation against the flow to ensure direct exposure of the electrodes.
•This installation is only recommended if the pipeline is completely filled and if there are no
particles or air bubbles in the pipeline.
Figure 4-6: Typical installation
1 Flow direction
2 Ordered sensor
Figure 4-7: Installation for clean water
1 Flow direction
2 Ordered sensor

4
ELECTRICAL CONNECTIONS
20
SMARTPAT COND 7200
www.krohne.com 02/2017 - 4003041302 - MA SMARTPAT COND 7200 R02 en
•This installation is only recommended if the pipeline is completely filled and if there are no
particles or air bubbles in the pipeline.
•Consider the diameter of the pipeline, i.e. compare pipeline DN with insertion length of the
sensor shaft.
•This installation is only recommended if the pipeline is completely filled and if there are no
particles or air bubbles in the pipeline.
•Consider the diameter of the pipeline, i.e. compare pipeline DN with insertion length of the
sensor shaft.
Figure 4-8: Possible installation
1 Flow direction
2 Ordered sensor
Figure 4-9: Possible installation
1 Flow direction
2 Ordered sensor
Table of contents
Other KROHNE Industrial Equipment manuals
Popular Industrial Equipment manuals by other brands

ABB
ABB ACS560 Hardware manual

VELCORP GEMS VELS
VELCORP GEMS VELS LC-1EY-HGS-R Assembly instruction

ITW
ITW SIMCO ION IQ Power Installation and operating instructions

ITOH DENKI
ITOH DENKI POWER MOLLER 24 F-RAT-S300 operating instructions

Reliable
Reliable 500PS instruction manual

TÜNKERS
TÜNKERS KN 40 UZ operating instructions