Ksenia auxi wls KSI2300002.300 User manual

code R30020.100en www.kseniasecurity.com
ed.04/2020
auxi wls
Wireles module 2 inputs/2outputs
868 MHZ bidirectional
Installation guide
INTRODUCTION
auxi wls is a wireless module with 2 built-in inputs and outputs. Powered directly from the mains, auxi wls is
ideal to remotely manage lights, home automations (such as roller blinds and curtains) and, generally, any
load unreachable by cables. auxi wls can be used in conjunction with lares 4.0 control panels or as a stand-
alone device. In the second case, the outputs can be controlled locally (using the inputs on board) or
remotely, using the opera remote control.
DESCRIPTION OF THE PRODUCT - TERMINALS - WIRING EXAMPLES
LEGEND
A - Terminal blocks
B - Programming button
C - Status LED
D - Serial Number Label
E - Radio Antenna DO NOT CUT
1 - Input 1
2 - Input 2
3 - Common relay contacts
4 - Power supply - neutral
5 - Relay output 1
6 - Power supply - phase
7 - Relay output 2

code R30020.100en www.kseniasecurity.com
ed.04/2020
TECHNICAL DATA
• Voltage: 110 -230 VAC 50-60Hz
• Frequency: 868 MHz
• Operative range in open air: up to 150m
• Inputs: Nr. 2
• Outputs: Nr. 2 (5A 250V~AC - 5A 30VDC)
• Operative range: -20 / + 55°C
• Dimensions: 42 x 35 x 20 mm
• Protection class: IP20
FUNCTIONS
STAND-ALONE
It is possible to manage relay outputs through
the closure of the inputs present on auxi wls
or using the opera remote commands previously
programmed.
LARES 4.0 CONTROL PANELS
Depending on its size, lares 4.0 control panels
can manage up to 64 auxi wls. The activation
of the outputs can be managed through
scenarios or using the built-in inputs on auxi wls.
Inputs present on auxi wls can work in different
ways:
• Local: no panel zone has to be associated to
the input, in order to work in this mode. The
2 inputs present on device could be used to
change the status of the outputs.
• As Panel zone: in order to work in this mode,
a Panel zone has to be assigned to the input.
The closure / opening of inputs is notified to
the Panel that will performs the programmed
actions during the real time of the associated
zone or its restoral.

code R30020.100en www.kseniasecurity.com
ed.04/2020
OUTPUTS WORKING MODES
Both in stand-alone or directly connected to the Panel, the relay outputs can be programmed as follows:
• INDIPENDENT OUTPUTS: both the outputs are completely independent and can be separately
programmed (eg. the first output as bistable and the second one as monostable).
• STPD (change over switch) OUTPUTS: the outputs are considered as an unique logic output. The first is
Normally Open and the second one is Normally Closed. The outputs are dependent and cannot be
separately managed. The commutation of the first relay implies the commutation of the second one.
• INTERLOCKED OUTPUTS: in this mode, particularly useful to manage electric motors, the relay outputs
cannot be active at the same time. In case an output is active and the other one has to be activated, both
of the outputs will be deactivated for half a second and then will commutate.
The outputs can be programmed as Bistable or Monostable, regardless the selected configuration.
OUTPUTS MANAGEMENT THROUGH LOCAL CONTACTS (STAND-ALONE | LARES 4.0)
What follows is valid only for using auxi wls as stand-alone device
or as peripheral on Panel, without associated zones (see above).
In case of independent or interlocked outputs, the first input
manage the first relay output and the second input manage the
second relay output. In case of STPD (change over switch) output
it is possible to use one or another input to manage the output.
At the changing of the inputs status, outputs react as follows:
• MONOSTABLE OUTPUT: If the input remains closed for less
than one second (use with short press of button), the output
is activated during the ON time. In case the output is already
active, the ON time is restarted, if the output is programmed
as independent or SPTD (change over switch). Otherwise the
ON time turns off, if the output is programmed as interlocked.
If the input remains closed for more than one second (use with
long press of button), the output commutates both at the
closure and at the re-opening of the input.
• BISTABLE OUTPUT: If the input remains closed for less than one
second, the output commutates only at the input closure. If the
input remains closed for more than one second, the output
commutates both at the closure and at the re-opening of the input.

code R30020.100en www.kseniasecurity.com
ed.04/2020
OUTPUTS MANAGEMENT THROUGH OPERA REMOTE COMMANDS (STAND-ALONE)
What follows is valid only for using auxi wls as stand-alone device. To manage outputs with opera remote
command it is necessary to enroll it. As explained in ‘Programming’ paragraph, each key of remote
command can be associated with an auxi wls or 0-1-2 keys can be programmed to manage the relay outputs
of 3 different auxi wls. To associate a single key of remote command to an auxi wls allows to manage up to
3 auxi wls at the same time, with the same remote command, if these are covered by the RF channel. In case
all the keys of opera remote command are associated to the same auxi wls, these operate as follows:
0 key This key turns the 2 outputs in stay mode. This
action is confirmed by turning on the central LED on
opera remote command.
1 key This key manages the first relay output. By pressing
this key, the outputs react depending on the
programming.
• If the output is programmed as monostable it be
activated and remains active during the ON time. In
case the output is already active and programmed
as independent or SPTD (change over switch), the
ON time is re-started. Otherwise it turns off, if the
output is programmed as interlocked.
• If the output is programmed as bistable, it
commutates at every press on the key
To confirm the operation, opera remote command
turns ON its left LED, if the outputs is activated and
turns ON the central LED, if the output is
deactivated.
2 key This key manage the second relay output By
pressing this key, the outputs react depending on
the programming.
• If the output is programmed as monostable it be
activated and remains active during the ON time. In
case the output is already active and programmed
as independent or SPTD (change over switch), the
ON time is re-started. Otherwise it turns off, if the
output is programmed as interlocked.
• If the output is programmed as bistable, it
commutates at every press on the key
To confirm the operation, opera remote command
turns ON its left LED, if the outputs is activated and
turns ON the central LED, if the output is
deactivated.
i key This key allows to visualize the outputs status.
The short press on this key displays the status of the
first output. If the output is active, the left LED of
opera turns ON, otherwise it turns ON the central
one.
The long press on the same key (more than 3
seconds) displays the status of the second output in
the same way as the first one.

code R30020.100en www.kseniasecurity.com
ed.04/2020
In case the keys of the same opera remote command are associated to different auxi wls, by pressing a key
the relay outputs react as follows:
OUTPUT MANAGEMENT THROUGH PANEL SCENARIOS
In case auxi wls is associated to a lares 4.0 control panel, the activation / deactivation of the outputs can be
managed also through the panel. In the same way as the panel outputs, the outputs on auxi wls can
commute when a particular event occurs, or can be manually activated through web server.
QUANTITY DATA
LED FUNCTIONS
Powering it up, the LED on device quickly blinks 3 times. Once stops blinking, if there are programmed opera
remote commands and the device is working in stand-alone mode, the led stays steady on. If the device
works as a wireless peripheral of the panel, the led turns OFF. Once the starting phase is over, the led
indicates the reception of a valid radio command.
0 1 2
keys
In case the outputs are programmed as
independents, a short press of the key manages
the first output and a long press manages the
second output. In case the output are
programmed as SPTD (change over switch),
there is no difference between the short or the
long press of the key, considering that the
outputs commute together.
In case the outputs are programmed as
interlocked, the outputs reaction depends on
the previous status of the relay outputs. The
activation sequence is: first output activation,
output deactivation, second output activation,
output deactivation, first output activation
again and so on. The LED on opera remote
command, corresponding to the pressed key,
turns ON to confirm the operation
(left led > key 0, right led > key 2).
i key not used
lares 4.0 models wls 96 16 40 40 wls 140 wls 644 wls
Maximum number of
auxi wls I/O
8820 20 64 64

code R30020.100en www.kseniasecurity.com
ed.04/2020
CONFIGURATION OF RADIO MODULE USING LARES 4.0 CONTROL PANEL
In order to work with the lares 4.0 control panels, auxi wls has to be enrolled as peripheral. The different
ways to enroll an auxi wls are described here below:
1. Insert the serial number of auxi wls directly from basis software
2. Set the panel on ‘Enrolling’ mode and power up the auxi wls
3. Set the panel on ‘Enrolling’ mode and press shortly on programming button on auxi wls
The outputs and the inputs can be programmed as normally open or normally closed.
Please refer to the lares 4.0 Programming Manual for more details.
CONFIGURATION OF RADIO MODULE AS STAND-ALONE DEVICE
In order to program auxi wls as stand-alone device, at least an opera remote command has to be memorized.
The procedures to memorize an opera remote command and to program the relay outputs are described
here below.
MEMORIZE OPERA REMOTE COMMANDS
In order to program the remote commands, hold the programming button on auxi wls for 3 seconds. The led
on device stays lit to confirm the access on programming mode. Hold the key “i” on remote command for 3
seconds, in order to memorize it. The led on auxi wls blinks 4 times to confirm the memorization. It could be
useful to use the same opera to manage more auxi wls placed on the same radio operational range. To
do this, avoiding conflicts, just associate a single key of remote command to a single auxi wls. In order to
associate only one key to an auxi wls, press the key you want to associate (0, 1 or 2) within the 5 seconds
after the confirm of memorization. A memorized remote command can be deleted by holding for 3 second
the key. The led on auxi wls quickly blinks 2 couple of times in order to confirm the deleted remote
command.
PROGRAMMATION OF FUNCTIONS OF RELAY OUTPUTS
Once the memorization of remote commands is over, by holding for 3 seconds the programming button on
auxi wls, it switches from the programming of remote commands to the programming of outputs. While in
outputs programming mode, the led on auxi wls blinks regularly (half a second ON, half a second OFF). At
this point, a memorized remote command can be used to program the outputs. Please see the tables here
below to program the outputs.

code R30020.100en www.kseniasecurity.com
ed.04/2020
By holding for 3 seconds the programming button on auxi wls, it exits from the programming mode of the
outputs and the device returns to the normal working mode. The led on device blinks at the exit of
programming mode, as at the start of programming.
NOTE: auxi wls have to be programmed one by one. DO NOT try to program more than one auxi at the same
time, to avoid conflicts.
INDEPENDENT
MONOSTABLE BISTABLE
relay output 1 relay output 2 relay output 1 relay output 2
Short press on key 1 of opera
remote command. Once
pressed, the first relay
switches and the led on auxi
wls starts blinking each
second. This indicates that
auxi wls start counting the
monostable time. By pressing
again, the relay re-opens and
the led on auxi wls quickly
blinks 3 times to confirm the
configuration saving. The
monostable time is the time
elapsed between the two
press on key.
Short press on key 2 of opera
remote command. Once
pressed, the first relay
switches and the led on auxi
wls starts blinking each
second. This indicates that
auxi wls start counting the
monostable time. By pressing
again, the relay re-opens and
the led on auxi wls quickly
blinks 3 times to confirm the
configuration saving. The
monostable time is the time
elapsed between the two
press on key.
Long press on key 1.
The led on auxi wls
blinks 3 times to
confirm the
configuration saving.
Long press on key 2. The
led on auxi wls blinks 3
times to confirm the
configuration saving.
SPTD Change over switch INTERLOCKED
MONOSTABLE BISTABLE MONOSTABLE BISTABLE
Short press on key 0 of opera
remote control. Once
pressed, the first relay
switches and the led on auxi
wls starts blinking each
second. This indicates that
auxi wls start counting the
monostable time. By pressing
again, the relay re-opens and
the led on auxi wls quickly
blinks 3 times to confirm the
configuration saving.
The monostable time is the
time elapsed between the
two press on key.
Long press on key 0 of
opera remote control.
The led on auxi wls
quickly blinks 3 times
to confirm the
configuration saving.
Short press on key (i) of opera
remote command. Once
pressed, the first relay
switches and the led on auxi
wls starts blinking each
second. This indicates that
auxi wls start counting the
monostable time. By pressing
again, the relay re-opens and
the led on auxi wls quickly
blinks 3 times to confirm the
configuration saving. The
monostable time is the time
elapsed between the two
press on key.
Long press on key (i) of
opera remote control.
The led on auxi wls
quickly blinks 3 times to
confirm the
configuration saving.

code R30020.100en www.kseniasecurity.com
ed.04/2020
FACTORY DATA RESET
On factory data configuration there are no opera remote commands memorized and the outputs are
programmed as independent and bistable.
In order to restore the factory default, hold the programming button on auxi wls for 10 seconds while it is in
normal working mode. The led on device stays steady on, then starts regularly blinking and finally shortly
blinks 3 times, like the first power up. These 3 blinks indicate the reset of factory data and auxi wls returns
to the normal working mode. In case the button is released before the end of procedure (3 blinks), if the
button is released while the led stays lit, auxi wls will enter in the remote commands programming, if the
button is released while the led blinks regularly it will enter in the outputs programming.
In case of factory data reset, auxi wls acts as a wireless peripheral on panel, considering that there are no
remote commands memorized.