1. The 3071PPAO lock is supplied factory default in Private User Mode i.e. for assigned locker Users
2. The Default factory Codes are: Master Override: 4321+OK Assigned User: 1234+OK
3. If the lock is required to operate in Public Share User Mode it needs to be changed from Assigned
User Mode as follows; Insert 4 x AA baeries in back box, insert the probe supplied or a paper-
clip into the single ’reset’ hole on the backbox and hold down as you insert the fourth AA baery.
Keep the probe held down unl the lock emits “three beeps” conrming Public Mode has been
set. Release the probe. If you do not get 3-beeps repeat the process
4. In Public Share Mode, share users can enter any 4-8 digit code + OK to lock and the same code to
unlock. Alternavely, share users can use any Mifare 13.56MHz RFID card/fob to lock and unlock
5. To change the Master Override Code enter the current Master Code and press ’C’ enter the new
Master Code + OK. The Master Code can be from 4-15 digits long. Always write the new Master
code down and always make code changes and test new codes with the locker door open.
6. To Change the Default User Code enter the current User code + C and whilst the green LED is
ashing enter the new 4-8 digit User Code + OK. Always leave door open when changing codes!
7. To enroll up to three Master Override RFID Cards/Fobs. Enter current Master Code Press ’C’ and
whilst green LED is ashing present the cards/fobs, one at a me. Enrolled cards are conrmed by
a single beep. If LED stops ashing before enrolling all 3 cards/fobs, repeat above process for the
remaining cards/fobs. Test by presenng each Master Card/Fob one at a me to lock and unlock
the lock (with the door open)
8. To Open lock when a user code is unknown or forgoen: Enter the Master Code + OK or, present
any of the three cards/fobs.
9. Auto Unlock Feature. The 3071PPAO has an auto open feature that can be set to automacally
open the lock between 1 and 1440 minutes aer being locked. To set the desired me period to
open aer locking, present a master card/fob at the lock and enter 4-digits represenng minutes
between 1-1440 + OK (e.g. To open aer 4-hours present card/fob enter 0240 +OK) If the Auto
Open feature is not required Present the Master Card/Fob press 0000 +OK otherwise the lock
will open aer 24-hours by factory default.
10. Emergency Power Supply. If the baeries are le to go at from ignoring the audible and visual
low baery warnings you will need to insert the Emergency Power Supply into the le side of the
keypad and enter the Master Override code + OK or present the Master Card/Fob at the keypad
WARNING
DEFAULT CODES CAN BE SOURCED FROM THE INTERNET. IT IS THEREFORE RECOMMENDED THAT THE
DEFAULT MASTER OVERRIDE AND USER CODES ARE CHANGED IMMEDIATELY FOLLOWING INSTALLATION
TO AVOID COVERT ACCESS INTO LOCKERS OR THEFT OF PERSONAL BELONGINGS. FOR MORE DETAILED
INSTRUCTIONS PLEASE REFER TO THE FULL KM3071PP-AO USER MANUAL OR CONTACT YOUR LOCKER
SUPPLIER

PLEASE NOTE: - LOCK IS SHIPPED IN PRIVATE MODE AS FACTORY DEFAULT SETTING
KM3071-PP AO Digital RFID Locker Lock
SHORTFORM INSTALLER INSTRUCTIONS
FOR CARD or PIN PUBLIC SHARE MODE OPERATION
Do not close the door until Master Fobs are enrolled and lock has been tested with default Master
override PIN 4321+OK and default User PIN 1234+OK. See User Manual for further details
Leave Locker Door Open at all times throughout the installation and programming
1. Install lock on door and connect Keypad to Latchbox making sure the two ridges on the ribbon
cable plug are facing UP to be correctly inserted into the socket of the latchbox connector.
Inserting the ribbon cable plug into the socket upside down will damage the pins in the
connector that will permanently damage the lock and void the warranty.
2. Insert 3 x AA quality brand batteries in the latchbox and insert the probe in the single reset hole
on the latchbox, keeping it held down as you insert the 4th AA battery until you hear 1 short
beep followed by 3 long beeps. Remove the probe after the 3 beeps. The latch bolt will
automatically retract back into the latchbox, and the lock will be set in Public Mode.
3. The lock is now in Public Share User Mode and can be operated by any 4-8 digit PIN to lock it
and the same PIN to unlock. It can also be operated by any Mifare 13.56MHz 1K RFID Card Fob
or Wristband by presenting the card/fob at the keypad to lock it and using the same
card/fob/wristband to unlock it. In Public Share User Mode, the lock can also be opened using
the Master Override PIN (default 4321+OK) or A Master Override Fob.
4. To enroll the 3 Master Override Fobs supplied with the locks (Red, Blue, and Yellow) enter the
Master PIN 4321+ C (Master Fob enrollment mode) and whilst green light is flashing, present
each override fob to where card/hand icon is indicated on the keypad confirmed by 1 beep and
a green light for each fob that has been enrolled
5. In Public Share User mode, the Auto Open feature can be activated to automatically open the
lock between 1 and 1440 minutes after being locked. This is to deter share locker users taking
ownership or extended use of the locker. To turn this feature off present any Master override
Fob and enter 0 0 0 0 + OK.
6. After enrolling the 3 fobs, Test lock with any temporary 4-8 digit pin +OK, latch will extract
ready to push door closed to lock and can be opened using same temporary PIN to open. When
lock is opened by a Master Fob or Master Override PIN the temporary User PIN is deleted and
the lock defaults to the ready share user mode for next user.
7. Test lock with default Master pin 4321+OK, latch will retract and 5 seconds later it will extend
ready for door to be pushed closed
8. Test lock with the 3 Master Fobs, and present all three Fobs one at a time (after the latch
automatically extends to locked position to confirm fobs unlock)
9. After Master PIN, User PIN, and the 3 Master Fobs have been tested you may now close the
locker door and test to ensure it opens using the User PIN or Master Fob
10. To set the Auto Open feature present any one of the 3 master Override Fobs at the Keypad
Reader and enter 4 digits representing minutes between 0001 and 1440 e.g., to have the lock
automatically open 1 hour after being locked by a temporary user, present Master Fob and
enter 0060 + OK
Advise your end user customer to instruct users not to overload the locker with private property that could apply pressure on the locker door
from the inside (e.g., backpacks, laptops, and any other bulky items) as this can apply undue pressure on the latch causing it to jam

PLEASE NOTE: - LOCK IS SHIPPED IN PRIVATE MODE AS FACTORY DEFAULT SETTING
KM3071-PP AO Digital RFID Locker Lock
SHORTFORM INSTALLER INSTRUCTIONS
FOR CARD or PIN PRIVATE MODE OPERATION
Do not close the door until Master Fobs are enrolled and lock has been tested with default Master
override PIN 4321+OK and default User PIN 1234+OK. See User Manual for further details
Leave Locker Door Open at all times throughout the installation and programming
1. Install lock on door and connect Keypad to Latchbox making sure the two ridges on the ribbon
cable plug are facing UP to be correctly inserted into the socket of the latchbox connector.
Inserting the ribbon cable plug into the socket upside down will damage the pins in the
connector that will permanently damage the lock and void the warranty.
2. Install 4 X AA quality brand batteries in latchbox, confirmed by 1 beep, a green light and the
latch bolt extending. For transit and packing purposes, the latchbox is shipped from the factory
with the latch retracted and the lock set in default Private mode. The lock is now ready to use in
Private mode and can be operated by the default user PIN 1234+OK and the Master PIN
4321+OK.
3. Now enroll the 3 Master Override Fobs supplied with the locks (Red, Blue, and Yellow) by
entering the Master PIN 4321+ C (Master Fob enrollment mode) whilst green light is flashing,
present each override fob to where card/hand icon is indicated on the keypad confirmed by 1
beep and a green light for each fob that has been correctly enrolled
4. In Private Mode the Auto Open feature is not active. This is only active in Public share user
mode. See separate instructions for this.
5. After enrolling the 3 fobs, Test lock with default user pin 1234+OK, latch will retract and 5
seconds later it will automatically extend. This only happens in Private User Mode so the door
can be pushed closed to lock it without the need of a card/fob or pin.
6. Test lock with default Master Pin 4321+OK, latch will retract and 5 seconds later it will extend
ready for door to be pushed closed
7. Test lock with the 3 Master Fobs and present all three Fobs one at a time after the latch
automatically extends to confirm all 3 fobs operate the lock. After Master PIN, User PIN, and
the 3 Master Fobs have been tested you may now close the locker door and test to ensure it
opens using the User PIN or Master Fob
SPECIAL INSTRUCTIONS
Make sure latch and striker plate are correctly aligned and latch does not bind on any part of the striker plate. A chattering
noise indicates the latch is not perfectly by aligned with striker plate, locker carcass is unlevel, items inside the locker are
putting pressure against the door or, batteries are going flat.
When connecting or disconnecting the Keypad backbox ribbon cable, do not pull on the ribbon cables to unplug it. The keypad
ribbon cable plug has two ridges on it which must face up for correct connection.
If door is locked and PIN or Master Fobs do not open the lock, firstly insert the power bank in the side of the keypad to apply
power to the lock in event of low batteries. If lock still doesn’t open by PIN or Fob remove the power bank from the USB cable
and using a paperclip bent into a U shape, put it the two ends into the two holes on the USB plug to reset the lock externally
Advise your end user customer to instruct users not to overload the locker with private property that could apply pressure on the locker door
from the inside (e.g., backpacks, laptops, and any other bulky items) as this can apply undue pressure on the latch causing it to jam

2
KM-3071-PPAO Overview
•The KM-3071-PPAO is factory pre-programmed in PRIVATE User Mode for assigned locker applicaons.
•It can be changed to PUBLIC user mode for share locker applicaons. (Refer to below for changing user mode).
•It features a digital touch screen keypad for operaon by a 4 to 8 digit PIN and an integrated Mifare 13.56MHz
RFID Card reader for operaon using Mifare cards, Fobs or Wristbands.
•The KM3071 PP AO features Master Override PIN (4 to 8 digits in length and up to 3 Master Override Cards/
Fobs or Wristbands). The KM 3071 PPAO can also be programmed for up to 17 individual User Card access
(useful for common lockers shared by mulple users e.g. staonery cupboards, storage lockers etc.)
•Another feature of the KM3071 PPAO is an auto opening funcon. This feature is used where lockers are
shared for a limited me only to deter user’s taking ownership of lockers. The auto mer can be set to open the
lock aer it has been locked from 0001 minute up to 1440 minutes (24 hours). If this feature is not required, it
must be disabled at me of installaon. (Refer to enabling/disabling auto open feature further in this manual).
•The KM3071 PPAO is supplied programmed with a default User code 1234 + OK and Master Code 4321 + OK.
•When KM3071 PPAO is in use, a faint green ashing LED is displayed at the boom of the keypad.
•The KM3071 PPAO is supplied with an an-fricon roller on the Striker plate to assist the latch opening and also
features a spring loaded plunger to slightly push the door ajar aer unlocking to assist accessible opening
An-fricon roller
Spring loaded plunger to push
door ajar aer unlocking
Green LED Indicator for programming
conrmaon and user/occupied status
San Silver Alloy Keypad Casing
Digital Touch Screen Keypad with
integrated RFID Card Reader
Emergency Power Input via mini
USB Connecon
KM3071PPAO Striker Plate

3
KM-3071-PP Digital Locker Lock with Touch Screen Keypad and Card Reader
REQUIRED COMPONENTS AND TOOLS
KM3071PP Digital Touch screen
Keypad with Mifare Card Reader
Lock Body and Baery box Striker Plate and installaon screws
and Emergency USB power cable.
Please conrm all lock parts are present. If there are ANY damaged or missing components contact your
KSQ product support specialist.
COMPONENTS SUPPLIED WITH THE LOCK
ADDITIONAL COMPONENTS REQUIRED PRIOR TO INSTALLING
PHILIPS HEAD SCREWDRIVER 3 x Mifare Cards, Fobs or Wristbands for lock Administrator
override or Assigned and Share User Access.
(3-Mifare devices are supplied with all orders MOQ 50+
KM3071 PPAO locks or more. Additional cards at cost.
4 x AA QUALITY BRAND HEAVY
DUTY ALKALINE BATTERIES
AC PLUG PACK FOR POWERING THE LOCKS TO ENABLE DESKTOP PROGRAMING
PRE INSTALLATION . THIS METHOD NEGATES INSTALLATION OF BATTERIES FOR
EVERY LOCK TO ENABLE PRTOGRAMMING. PRE-PROGRAMMED LOCKS WILL RETAIN
MEMORY FOR UP TO 3 MONTHS WITHOUT POWER. OPTIONAL COST POA
OPTIONAL EMERGENCY POWER PACK FOR PROVIDING POWER TO THE LOCKS IN
THE EVENT OF FLAT BATTERIES. THE EMERGENCY POWER PACK PLUGS INTO THE
KM3071 KEYPAD USING THE USB CABLE SUPPLIED WITH THE LOCK. OPTIONAL COST
POA
OR

4
Private User Mode (Private Operaon)
Fixed User mode is for private use, for when a user has been assigned
their own personal locker. In this mode, the user card must rst be en-
rolled into the lock before it will work. In this mode, once a user card is
enrolled, it will not require the card to close, and will automacally
re-lock.
Public User Mode (Shared Operaon)
Public User Mode that any user can use any PIN or Card on any lock to operate it.
When the user unlocks the original lock again, the lock resets awaing the next user,
and the user card is now free to operate any lock once more. Please note that when
Public user mode is acvated, the automac opening feature is acvated.
If the automac opening feature is not required then it must be cancelled.
To cancel the auto open feature, swipe the master card and the green LED will ash.
Whilst ashing, swipe the master card once more and then enter 0000 + OK on the
keypad, this will be conrmed by 1 beep.
KM-3071-PPAO Operang Modes
The KM-3071-PP features 2 operang modes: Private User Mode and Public User Mode
To Change the operang mode from the factory default Private User Mode, follow the below steps or refer to page 4.
1)Remove one baery and insert the supplied probe into the reset hole as pictured below.
2) Re-insert the baery and keep the probe held in for 2 seconds unl the lock emits 2 beeps.
3) DO NOT SHUT THE DOOR—Test the lock with a 4 digit PIN. Enter the same 4 digit PIN to conrm.
•Public User Mode PIN/CARD Required to Lock and Unlock
•Private User Mode PIN/CARD only Required to Unlock (Auto Relock Feature)
To unlock in Private User Mode with Card, touch the reader with User Fob, LED will ash once and beep once and
latch will retract. Ready to be relocked by presenng the User Fob again.
To lock in Private User Mode with Card.
Touch the reader with User Fob for one beep, LED will ash quickly for 2 seconds and latch will extend conrmed by
two beeps, ready for locking by closing the door.
To lock in Public user mode with Card
Present your card over the keypad to lock the lock.
To unlock in public user mode with Card .
Present the same user card over the keypad to unlock the lock.

5
Inialising the Lock—First Time Start
The rst step is to connect the cable from the locks back box to the reader and proceed to insert 4 quality AA
baeries.
•PLEASE READ BELOW INSTRUCTIONS CAREFULLY TO SAVE TIME IN COMMISSIONING PROCESS -
The lock factory default mode is Private User Mode.
•To change the lock into one me user mode—Refer to step 3 below
Touch Screen and Mifare Card Reader Back of Reader Lock Back Box
2: Insert Four (4) alkaline AA
baeries and replace the cover
1: Connect Cable from back-
box to the rear of the Reader
3. To program the lock for Public/One Time User mode
one me user mode.
PLEASE NOTE:
Remove one baery and insert the supplied probe into the reset hole as pictured below. Re-insert the baery
and keep the probe held in for 2 seconds unl the lock emits 3 beeps. This conrms the locks is now in the
If the lock is set in public user mode, the automac opening feature will be acvated.
w
Please ensure you turn
this feature o it is it not required. To turn the auto open feature o, swipe the master card, hile the green
LED is ashing, enter 0000 + OK.
Note: Picture shows back latch
in white for clarity. All
KM3071PPAO locks are now
supplied with Black Back Latch.
Note: Picture shows back
latch in white for clarity. All
KM3071PPAO locks are now
supplied with Black Back
Latch.

6
To enroll the Master Key, rst enter the default management code of 4321+ C . The lock will begin to unlock and
the green LED will ash on the face of the keypad. Whilst green LED is ashing, present the card over the keypad to
enroll it as a Master Card. Up to 3 Master Cards can be enrolled into each lock (or the same 3 master cards can be
enrolled in all locks) Enrollment of Master Card/s is conrmed by 1 long beep.
To enrol the user card, swipe the management card over the keypad, the green LED will light up, the lock will un-
lock and the green LED will begin to ash. Present the master card over the keypad once more and the lock will
beep, now present the desired user card over the keypad to enrol it as the user card. This is conrmed by 1 beep.
Present the next card on the keypad whilst the green LED is ashing to enrol mulple user cards. Up to a
maximum of 20 user cards can be enrolled into each lock or all locks.
To delete the user card, present the management card on the keypad and the lock will emit 1 beep. Present the
master card back on the keypad, you will get another beep and the lock indicator light will begin to ash. Present
the master key once more and the locking indicator will begin to ash faster. Present the user cards you wish to
delete, conrmed by 1 beep.
WRITE DOWN YOUR NEW MASTER CODE! The factory default Master Code is 4321 + OK
ALWAYS LEAVE THE DOOR OPEN WHEN ENROLLING CARDS OR CHANGING MASTER OR USER PINS
To change the master code, enter the current master code + C . The lock will emit a long buzz and the unlocking
indicator will ash on the keypad. Enter your new Master Code and press OK to conrm. The lock will emit a long
beep conrming the enrolment of the new code. Please note that the Master Code can 4-15 Digits in length. Always
test the new master code at the lock with the door open to conrm the new master code works.
WRITE DOWN NEW DESIRED USER CODE! The factory default User Code is 1234.
To change the user code, enter the current user code + C . The lock will emit a long buzz and the unlocking indicator
will ash on the keypad. Enter your new User Code and press OK to conrm. The lock will emit a long beep conrm-
ing the enrolment of the new code. Please note that the User Code can be 4-15 Digits in length. Test the lock with
the door open to conrm the new User code works.
To lock in Private User Mode, In private user mode the latch automacally extends aer unlocking. To lock, simply
close the door.
To unlock in Private User Mode, touch the reader with User Fob, LED will ash once and beep once and latch will
retract. Aer 5 seconds the latch will automacally extract ready for relocking. Do not leave your card inside the
locker!
Programming the Master Key
4321 + C, whilst green LED is ashing, present Master Card over the keypad, enrolment conrmed by 1 long beep.
Present another card to enrol addional Master Cards—Maximum 3 per lock
Changing the Master Code
Changing the User Code
4321 + C
GREEN LED FLASHING
Programming the User Card
Deleng the User Card

7
Reseng the User Code in Permanent User Mode
To reset the user code back to the factory default of 1234, unlock the lock using the master code. This will reset the
user code back to factory default of 1234 allowing the next user to set up their own unique permanent PIN.
Programming the Automac Opening Feature
Examples: To set the lock to open in 1-hour AFTER LOCKING present master card, enter ‘0060’ + OK or for 2-hours
present master card enter ‘0120’ +OK or 12-hours ‘0720’ + OK or 1440 +OK for 24-hours.
To cancel the mer from auto opening the lock aer locking , present the master card over the keypad, the LED
will ash and whilst LED is ashing, enter 0000 + OK. (conrmed by 1-beep) You must do this if the auto me
open feature is not used for both the Private mode and Public Mode
Mung the keypad sounds
To silence the audible indicators (keypad sounds) , press and Hold OK on the lock for 5 seconds, the green LED will
ash once to conrm the lock is now in silent mode. Please note, in
silent mode the lock will not emit any beeps to indicate any funcons performed via the keypad. For ease of program-
ming, KSQ recommend to enable the silent mode on the lock aer it has been programmed and tested with the new
master code. To RE-acvate the audible nocaons (keypad sounds) press and hold the OK buon for 5 seconds, the
LED will ash and the lock will beep once to conrm the audible keypad sounds are acve.
The automac opening feature can be programmed so that the lock will automacally unlock aer a set period of
me, anywhere from 1 minute up to 24 hours aer each use. To program the automac opening me, present the
master card over the keypad to unlock the lock, the green LED will ash. Whilst the LED is ashing, enter 4 digits
represenng the number of minutes you want the lock to automacally open aer being locked by a user.

8
When the lock is rst used with a User or Master Code the lock may emit a chaering noise. This is a normal funcon
of the lock and not a fault.
Check with your installer to ensure that the latch bolt and striker plate are perfectly aligned.
(Refer to Page 2 Please Note)
ADDENDUM - LOCK CHARACTERISTICS AND FAULT FINDING
Other things that can cause problems with the latch operaon are, overghtening of the screws in the backbox that
hold the keypad on. To overcome this loosen the screws slightly and test the lock with the door open. If the lock
operates normally when the locker door is in the open posion, then most problems are invariably associated with the
installaon; such as a misalignment of the lock latch with the striker plate, (either too ght, too high or too low)
causing the latch to jam, mis-adjustment of the hinges aecng posioning of the door and latch aligning with the
striker plate, movement in the locker carcass such as not being perfectly level, or bulky items inside the locker pung
undue pressure on the locker door prevenng the latch from freely operang.
When the 3071PPAO lock is rst POWERED UP it will be in factory default mode of Private User operation with preset
factory default PINs of 4321+OK as Master PIN and 1234+OK. The latch bolt will be extended allowing the door to be
pushed closed to lock without card or PIN. To Change the Mode from Private to Public, install 3 AA batteries, and reserve
a 4th battery to insert at the same time that you insert a probe or paper clip into the RESET hole on the battery backbox.
Hold the probe down as you insert the 4th battery and wait until you hear 3 beeps confirming that the lock has been
changed from Private to Public share mode.
When the lock is set in Public share mode the latch will be retracted, waiting for a share user RFID card to be presented
or a share user PIN to be entered to extend the latch. After the lock mode has been changed and when a share RFID card
or PIN is used the lock the lock, the lock may produce a chattering noise. This is normal when the latch position
internallyresets for the selected mode. After the Card or PIN is used the latch will be extended ready to close the door.
To enrol the Master Cards, enter the Master PIN 4321+ C and whilst the green LED is flashing, present up to 3 RFID cards
at the keypad/reader one after the other. As each card is enrolled you will get 1 beep. If you do not manage to enrol all 3
Master Cards at the same time, repeat the process.
When the lock has been reset to Public Mode the Auto-Open timer is enabled. If you do not want the lock to
automatically open in Share User mode you need to DISABLE the timer feature. Present a Master Card at the keypad
reader and then enter 0-0-0-0 to turn off the timer. If you do not turn of the timer the lock will automatically unlock
after 24-hours. If you want to use the timer for deterring Users taking ownership of the lockers present a Master card
at the keypad reader and then enter 4-digits that numerically represent minutes between 0001 for 1 minute and 1440
minutes for 24-hours. e.g, 0060 would be 1 hour, 0120 would be 2 hours 0480 would be 8 hours.
If you insert a probe into the reset hole and hold down the button you will revert the lock back to Private User
Mode and any master or user cards that were previously enrolled will be deleted .is chaering noise should NOT
be experienced for normal use unless the latch is obstructed or, is binding against the striker plate or, the locker
door has pressure against it from bulky items stored inside the locker prevenng the latch from retracng.

9
The KM-3071-PP features a low voltage alarm that will acvate when the locks baeries fall below 4V.
If the locks emits 3 beeps and 3 quick ashes of the green LED aer use, then the baeries need to be changed
immediately. If the lock is stuck in the locked posion and the baeries are at, insert the emergency power pack into
the small input located on the right hand side of the keypad reader. Unlock using either the user or master card/Pin
If the locks an-tamper alarm is acvated, present a Master Card to cancel it.
TO CANCEL ALARMS FOR ANTI-TAMPER, FORCED LATCH OR LOW BATTERY ALARMS
Oponal Emergency Power Supply EPS-3071
For powering lock when baeries are at. Requires 4 x
1.5 AAA baeries , supplied with Micro USB Cable
Oponal Power Plug Pack KM3071-PPAO
For powering the locks without baeries to enable ‘bench-top’ pre-
programming of the customers requirements including the enrollment
of the master cards, seng the correct user mode and programming the
automac opening feature. This greatly reduces the me involved with
the inial programming and commissioning of the locks before use by
negang baery installaon
KSQ strongly recommend that you always test the lock with the door
open and check that both master override cards/Pins are working prior
to closing the locker door.
This device requires a standard 240VAC power outlet and extension lead.
FOR TECHNICAL SUPPORT CONTACT YOUR INSTALLER OR THE AUSTRALIAN DISTRIBUTOR BELOW
www.ksq.com.au sales@ksq.com.au 07 ) 55 26 27 26

TROUBLE SHOOTING CLICKING OR A RATCHET NOISE COMING FROM THE
KM3071PPAO DIGITAL TOUCHSCREEN RFID LOCKER LOCK
A clicking or ratcheng noise coming from the lock is generally caused by the latchbolt being out of sync
with the gear wheels in the back box. This mainly happens when the latch bolt tries to extract but
becomes obstructed. Obstrucons are mainly caused by,
(a) The door not being completely closed and the latch not properly aligned with the striker plate or,
(b) Bulky items in the locker prevenng the door from closing and or items pung pressure against the
door from the inside and prevenng the latch from operang freely.
(c) It can also happen due to the spring loaded plunger on the striker plate prevenng the door from
closing completely and the latch hing the locker carcass or the striker plate, which commonly
happens with locks being used in locker mode and when the user enters their code whilst the door
is sll ajar.
Best pracce for assigned locker users, is to wait for the latch to automacally extract (around 3-4 sec-
onds aer being opened) and then push the door rmly closed so the latch goes into the striker plate.
Best pracce for share locker users, is to place their belongings into the locker, enter their temporary
code with the door open to extract the latch and then push the door rmly to closed so that the latch
goes into the striker plate.
When the KM3071PPAO lock is out of sync and the door is open you should perform a manual reset by
pung a probe or paper clip into the single reset hole on the back box, and holding it in for 1 beep. This
resets the lock back to factory default sengs and will resync the latch. When the lock is reset, the
Master Pin and User Pin will both go back to the default seng of Master 4321 +OK and User 1234 + OK.
If the locks are being used in share locker mode and you perform the manual reset as per above, the lock
will also default back to the assigned Private User Mode and you will need to be reset it to the Share User
Mode. Please refer to instrucons Page 2 to set the lock to Public Share User Mode.
When the KM3071PPAO lock is out of sync and the door is locked and does not respond to the Master
Fobs or the Master Pin you can perform a reset from the keypad as follows:
Using the USB -C external power cable (supplied with the emergency power bank) insert the cable
without the power bank connected, into the C-port on the le side of the keypad. You will need a paper-
clip bent into a ‘U’ shape so that both ends are exactly the same length. Insert the paperclip into the USB
end of the cable and short out the two metal contacts in the plug unl you get a beep and green LED.
Then enter the default Master Pin 4321+OK or the default User Pin to open the lock. If the lock is not
responding to the above (no beep or LED) the problem may be due to low baeries. Aach the USB-C
cable to the Emergency Power Bank insert it into the keypad and enter the known Master Pin or Default
Master Pin 4321+OK.
Please Note:
When ever you do a reset on the KM3071PPAO from the latchbox or keypad using the USB-C cable, the
lock will default to factory sengs as explained in above. It also deletes the original User PIN and the 3
RFID Fobs. Please refer to the cheat sheets in aached. If the lock connues to be problemac then
return the lock to KSQ and we’ll send a replacement. If the returned lock is not assessed as being faulty
under warranty you will be charged for the replacement new lock at the current List Price and postage.

TROUBLE SHOOTING CLICKING OR A RATCHET NOISE COMING FROM THE
KM3071PPAO DIGITAL TOUCHSCREEN RFID LOCKER LOCK
WARNING! PERFORM THE FOLLOWING INSTRUCTIONS WITH THE LOCKER DOOR OPEN AT ALL TIMES
Insert the USB-C small cable plug into the USB-C port without the Emergency Power
Bank connected. Use a straightened paperclip bent into a U–shape so both ends are
equal length, and insert the paperclip into the two open holes of the large USB plug
to short out the two metal contacts and reset the lock (Conrmed by a beep and a
green LED)
Reseng the lock from the Touchscreen Keypad using USB-C cable
KSQ
1 2 3
4 5 6
7 8 9
C 0 OK
KM3071PPAO
USB-C Port
USB Plug
Paperclip bent into U shape
so both ends are equal.
o
O
Aer Reseng the lock you need to set a new Master Pin and enroll the three Master RFID Fobs.
1. Write down the New Master Pin !
2. Enter 4321+ C the green LED will start ashing, enter New Master Pin (4-8 digits) and Press OK. Enter the New
Master Pin to Test followed by OK. Latchbolt should retract and 3-4 seconds later , automacally eject
To enroll the three Master Override RFID Fobs
3. Enter Master Pin and Press ’C’ a Green LED will start ashing. Present each RFID Fob one aer the other to enroll
them whilst LED is ashing. If LED mes out repeat the above to enroll remaining fob/s. Test all three Fobs aer
enrolling by presenng the fob to the keypad to unlock the latchbolt.
Single Reset Hole.
Insert the Probe and hold it down unl you hear a long single beep and remove the
Probe. The Latchbolt will retract. Now enter the default User Pin 1234+OK. The lock
will emit the loud ratcheng noise conrming a resync and then eject the Latch-
bolt .The lock is now ready to be reprogrammed.
Reset Probe or a straightened paperclip
Reseng the lock from the Latchbox for Assigned Private User Operaon Latchbolt
Remove One
baery from the Backbox, insert the Reset Probe into the Single Reset Hole and hold it
down whilst inserng the 4th baery. Keep the probe in unl you get a single beep
followed soon aer by 3 beeps and the Latchbolt retracng, conrming that the lock
has been successfully reprogrammed for Public Share User operaon. In Public User
Mode the latchbolt is always retracted unl a temporary User enters their 4-8 digit
PIN to extract the latchbolt. Aer unlocking the last temporary User Pin is delet-
ed and the lock is reset ready for the next temporary User. In Public Share User Mode,
it is recommended for the User to enter their Pin rst and then close the door
Reset Probe or a straightened paperclip
Single Reset Hole.
Reseng the lock and Changing to Public Share Mode Operaon
o
1
2
3
4
Latchbolt

10

11
KM-3071-PP DIMENSIONS
KEYPAD SIDE VIEW
FOR TECHNICAL SUPPORT CONTACT YOUR INSTALLER OR THE AUSTRALIAN DISTRIBUTOR BELOW
KeyWatch Systems Qld sales@ksq.com.au (07) 55 26 27 26
Table of contents
Other KSQ Lock manuals
Popular Lock manuals by other brands

Simons Voss Technologies
Simons Voss Technologies LockNode SREL2.G2 quick guide

DOM
DOM Tronic Pro instructions

Esco
Esco systeQ-M-B2H-ESC Installation, operation and maintenance instructions

Lockwood
Lockwood PADDE TRIMEC 200 Series installation instructions

COMPX
COMPX 230SERIES manual

Burg Wächter
Burg Wächter secuENTRY ENTRY 7710 RFID manual