2.1.2 Alarm Off button and Alarm function
If the temperature of the FC room detector is higher or equal -9 °C the alarm LED and
the accoustic signal transmitter will be activated.
The accoustic signal transmitter can be switched oof by pressing the alarm off button; the
alarm LED is still on. Accoustic signal and alarm LED are extinguished, if the temperature is
colder than -14 °C again.
2.1.3 Memory button and Memory function
If the preset rated temperature is reached again after an alarm signal, the temperature
indicator continues to flash until the Memory button is pressed. By pressing the Memory
button, the highest freezer temperature is displayed for 5 sec. before the indicator is reset to
the actual temperature.
2.1.4 FC temperature selector and FC temperature indicator
The FC temperature indicator shows the rated temperature. If the FC temperature selector
button is pressed, the actual rated value is indicated for 5 sec. The possible temperature
setting range is between -18 °C and -26 °C. Setting is performed in increments of 1 degree.
Each depression of the button reduces the temperature by 1 K. If the button is continually
pressed, the rated temperature is continually changed in a 1 second-cycle.
The display may only be changed in increments of 1 K in order to prevent it from flickering.
The entire display range is between +39 °C and -39 °C. The FC display shows a corrected
measured FC room detector temperature.
2.1.5 RC temperature selector and RC temperature indicator
The RC temperature indicator shows the actual temperature. If the refrigerator temperature
selector button is pressed, the actual rated value is displayed for 5 sec. The possible
temperature setting range is between 2 °C and 11 °C. Setting is performed in increments of
1 degree. Each depression of the button reduces the temperature by 1 K.
The display may only be changed in steps of 1 K in order to prevent it from flickering. The
matching speed amounts to max. 1 K per 10 min. up to 16 °C. In case of higher temperatures,
the matching speed amounts to 1 K per 4 min. The entire display range is between 0 °C and
39 °C. The RC display shows a corrected measured RC room detector temperature.
VKS-H Technical Manual
KE 320-4-2T H8-420-02-01
Responsible: K.H. Hiby Phone: (0209) 401-732 Fax: (0209) 401-743 Date: 28.01.1998
For internal use only 6