The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation
(1/8 rated power); and during extreme heavy duty operation (1/4 rated power).
Current Draw and Thermal Dissipation
FP+ Series: Dedicated Touring Amplifiers
FP 6000Q
FP 6000Q
Level Load Rated Power Line Current *2) Watt *1) Thermal Dissipation
115 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standby, with remote power off via NomadLink 0 0 0 0 0
Powered on, idling 134 0134 456 115
Amp (I) Watt
Pink noise (1/8
rated power)
16 Ω/ Ch. 320 x4
6.9 3.5 423 160 263 898 226
32 Ω/ Bridged 640 x2
8 Ω/ Ch. 625 x4
10.9 5.4 700 313 388 1323 333
16 Ω/ Bridged 1250 x2
4 Ω/ Ch. 1250 x4
18.0 9.0 1215 625 590 2015 508
8 Ω/ Bridged 2500 x2
2 Ω/ Ch. 1500 x4
22.8 11.4 1575 750 825 2817 710
4 Ω/ Bridged 3000 x2
Pink noise (1/4
rated power)
*3)
16 Ω/ Ch. 320 x4
11.8 5.9 771 427 344 1175 296
32 Ω/ Bridged 640 x2
8 Ω/ Ch. 625 x4
20.0 10.0 1402 833 569 1942 489
16 Ω/ Bridged 1250 x2
4 Ω/ Ch. 1250 x4
37.3 18.6 2748 1667 1081 3690 930
8 Ω/ Bridged 2500 x2
2 Ω/ Ch. 1500 x4
38.9 19.4 2872 2000 872 2977 750
4 Ω/ Bridged 3000 x2
Mains connector, 230 V CE version 16 A, CEE7
Mains connector, 115 V ETL version 30 A, Nema L5 -30P Twist lock
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and
specified here is what is known as the “Active Power” of the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated
power. Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be
tripped even if operation is in excess of max. ratings.