LabRepCo LABH?14?SD User manual

GENERALPURPOSEREFRIGERATORSMODEL:LABH‐14‐SD,
LABH‐9‐SD,LABH‐17‐SD,LABH‐20‐SD,LABH‐30‐SD,
LABH‐30‐HG,LABH‐30‐HGC
OWNER’SINSTRUCTIONS
Thismanualdescribeshowtooperateandcareforyourappliancetogetthebest,mostefficient,performance.
READTHISBOOK!
NotetoCustomer:
Thismerchandisewascarefullypackedandthoroughlyinspectedbeforeleavingourplant.Responsibilityforits
safedeliverywasassumedbythecarrieruponacceptanceoftheshipment.Asdirectedonthesideofyour
packingcarton,claimsforlossordamagesustainedintransitmustbemadeonthecarrierasfollows:
A.) VisibleLoss,Damage,ShortageExternalEvidenceofLossorDamage:Thistypeofdamagemustbenotedon
thefreightbillandacknowledgedbythecarrier’sagent(driver)attimeofdelivery.Makesureyougetasigned
copy.Sendawrittenrequestforaninspectiontothecarrier.
B.) ConcealedDamage:Thistypeofdamagemaynotbediscovereduntiltheunitisbeingunpacked.When
concealeddamageisdiscovered,stopunpackingimmediatelyandcontactthecarrierimmediatelytoreport
theclaimandrequestaninspection.Thisshouldbedoneassoonaspossibleand,inanycase,mustbedone
within15daysorreceivingthemerchandise.Ifatallpossible,donotmovetheitemandsaveallpackaging
materialforcarrier’sinspection.
C.) FAILURETOFOLLOWTHESEINSTRUCTIONSMAYRESULTINTHECARRIERREFUSINGTOHONORYOUR
COMPANY’SCLAIM.UNDERNOCIRCUMSTANCESSHOULDTHEMERCHANDISEBERETURNEDTOTHE
MANUFACTURER.NORETURNSWILLBEACCEPTEDWITHOUTPRIORAUTHORIZATION.
Horizon Scientific
125 Varnfield Drive
Summerville, SC 29483
Phone: 800-648-4041
Fax: 843-821-8051
Warranty:
Two-Year Parts and Labor
5 Years Compressor Parts
Revision Date
03/12/11

2
TABLEOFCONTENTS
RECEIVING..........................................................................................3
INSTALLATION....................................................................................4
REFRIGERATOROPERATION...............................................................6
QUICKTROUBLESHOOTINGGUIDE.....................................................7
MAINTENANCEANDCLEANING..........................................................8
PRODUCTWARRANTYINFORMATION..............................................10
BEFORECALLINGTHEMANUFACTURER’STECHNICALSUPPORTDEPARTMENT,pleasehavethe
unit’smodelandserialnumberreadyaswellastheproblemdescription.Themodelandserial
numberislocatedontheserialtagwhichcanbefoundontheinteriorleftupperwallofthe
unit.
Forconvenience,youmaywanttorecordthefollowinginformationhereforeasyaccessinthe
future.
Modelnumber:__________________________________
Serialnumber:__________________________________
Dateofdelivery:_________________________________

3
RECEIVING
Yourunitwasbuilt,packaged,andinspectedwithextremecare.Weshippedittoyouusing
carrierswetrustwithaproventrackrecordofcarefulhandling,goodcustomerservice,andon
timedelivery.Unfortunately,regardlessofalloftheseeffortssometimesaccidentshappenand
occasionallythoseaccidentsresultinshippingdamage.Whenthecarrierpickedupthe
merchandisefromus,theyassumedresponsibilityforitsconditionenroutetoyou.Thus,any
claimsforshippingdamagemustbefiledwiththecarrier.Likeanybodyelse,carriersdon’tlike
topayoutoninsuranceclaims,sotheirclaimsproceduresandrequirementsarevery
restrictive.Youshouldconsultthecarrier’swebsitefortheirspecificclaimsprocedures.You
shouldalsoknowthattimeisoftheessence.
Therearetwogeneraltypesofshippingdamage.Thefirstisvisibledamage.Thistypeof
damageincludesvisibleloss,damage,shortageoranyexternalevidenceoflossordamagethat
isvisibleattimeofdelivery.Thistypeofdamagemustbenotedindetailonyourdelivery
receipt.Makesurethedriversignsanddatesthedeliveryreceipt,acknowledgingthe
damage.Thishastohappenatthetimeofdeliveryoritwon’thappenatall.Keepacopyfor
yourrecordsandsendanothertothecarrier’sdamageclaimsdepartmentalongwithaformal
requestforaninspectionreport.Followupwithaphonecall.Theircontactinformationcanbe
foundonthecarrier’swebsite.
Thesecondtypeofshippingdamageisconcealeddamage.Thistypeofdamagewillprobably
notbeapparentattimeofdeliveryandmaynotbediscovereduntilunpackingandinspecting
theunit.Remember,timeisoftheessencehere.Youshouldunpackandinspecttheunitas
soonaspossible.Eachdaythatpassesreducesthelikelihoodthatthecarrierwillpaytheclaim.
Assoonastheconcealeddamageisdiscovered,stopunpackingandretainallpacking
materials.Contactthecarrierbyphonetoreporttheclaim.Notethedateandtimeand
personyouspokewith.Getaclaimnumber.Followupwithawrittenletterreferencingthe
claimnumberandincludingaformalrequestforaninspection.Again,consultthecarrier’s
websiteforspecificclaiminstructionsandfollowthemprecisely.
ASSTATEDABOVE,THECARRIERISYOURSOLESOURCEFORSATISFACTIONOFADAMAGE
CLAIM.UNDERNOCIRCUMSTANCESSHOULDTHEMERCHANDISEBERETURNEDTOTHE
MANUFACTURER.NORETURNSWILLBEACCEPTEDWITHOUTPRIORAUTHORIZATION.

4
INSTALLATION
UNCRATING–Moveyourrefrigeratorasclosetothefinallocation
aspossiblebeforeunpacking.Removethewoodenplanksor
skid.Thelocationshouldbeascloseaspossibletothepower
outletsotheextensioncordisnotneeded.Thisunitrequiresa
minimumof4inchesofairflowspaceinbackand3incheson
thesidesandtop.Donotstorematerialonthetopofthis
unit.
LEVELINGYoucanlevelyourunitwiththescrew‐typeadjustablelevelinglegsonthefront
cornersoftheunit.Turncounterclockwisetoraisethecorner;turnclockwisetolowerit.
Levelinglegsarerequiredinfrontonly.Unitmayhaveaslighttiltfromfronttobackafter
legsareinstalled.Thisisacceptableandisrecommendedonthisunit.
POWERSOURCE–Thesupplycircuittothiscabinet
mustconformtoallNationalandLocalElectrical
Codes.ConsultthecabinetSerial‐Dataplatefor
voltage,cycle,phase,andamprequirementsbefore
makingconnection.VOLTAGESHOULDNOTVARY
MORETHAN5%FROMSERIALPLATERATINGS.A
separatecircuitisrecommendedtopreventpossible
lossofproductduetoover‐loadingorfailureofotherequipmentonthesamecircuit.
PROTECTTHECIRCUITWITHA20AMPDELAY‐TYPE
FUSEORCIRCUITBREAKER.Donotuseanextension
cord.Besureyourunitisproperlygrounded.Usethe
3‐prongplugprovidedintoa3‐pronggroundedoutlet.
(Onlythismethodcomplieswithnationalelectrical
codes,localcodesandordinances.)Unlesstheabove
groundingmethodisfollowed,youarenotprotected
againstsevereorlethalshockintheeventofashort
circuitofanelectricalcomponentorwiringoftheunit.
STARTING–Therearenocompressorshippingboltsto
loosenorvalvestoopen.Allthatisnecessaryafterthe
unithasbeenproperlyleveledistoplugtheservice
cordintoanelectricaloutletWhenstartingthisnew
appliance,allowthecabinettooperateaminimumofeighthoursoruntilithasstarted
cyclingnormallybeforeplacingproductinthecabinet.Themotorcompressormaystart
andstopseveraltimeswhentheunitisfirststartedorafterdefrosting,especiallyifthe
weatherisveryhot.Thisisonlynormalfunctioningofthemotoroverloadprotector.The
motorcompressorwillcyclenormallyassoonastheexcessheathasbeenremoved.

5
ShelfInstallation(NOTONALLMODELS)
Hookshelfclipsontopilasterstrips(seeIllustration).Positionallfourshelfclipsequalin
distancefromthefloorforflatshelves.Wireshelvesareorientedsothatcrosssupportbarsare
facingdown.
Placeshelvesonshelfclipsmakingsureallcornersareseatedproperly.
Temperaturecontrol
NOTE:Thecontrolispresetatthefactorytoprovidethedesiredairandproduct
temperaturesinsideoftheunitandrequiresnofurtheradjustment.Pleasecontactthe
manufacturer’sTechnicalSupportDepartmentbeforemakinganyadjustmentstodetermine
ifadjustmentisnecessaryand,ifso,tomakesureitisperformedproperly.
Thisunithasamanualthermostatlocatedinsideofthecompartment.Thisthermostatcontrols
thecompressor.Turningthethermostattowardsthehighernumberswillmaketheunitcolder.
Lowernumbersmakeitwarmer.Turningthethermostattotheoffor0positionwillturnthe
unitoff.

6
RefrigeratorOperation
Aftertheunitisproperlyinstalledandpowerisapplied,itwilltakesometimebeforethe
systemiscooleddowntotemperatureandcyclingnormally.Youshouldwait8hoursonthe
firststartupbeforebeginningtoaddproducttotheunit.Thisensuresthattheunitisinstalled
andoperatingproperlybeforebeingputintoservice.Onsubsequentstartups(aftercleanings,
forexample),thiswaittimecanbereducedtoabout3hours.Afterthiswaittime,theunit
shouldbecyclinginthedesigntemperaturerange.Theunitsarecalibratedbeforeleavingthe
factory,sonoadjustmentshouldbenecessary.
Loadingtheunitswillagaincausetemperaturetoriseasthewarmerproductisintroducedinto
thecompartment.Ifalargeamountofproductistobeintroduced,itisagoodideatodoitin
stages,allowingseveralhoursbetweenstagestoallowtemperaturetostabilizeagainbefore
introducingadditionalwarmproduct.Thiswillminimizethetemperaturetransientwhile
loading.Othertipsforsuccessfulloadinginclude:
‐Leaveabout2‐3inchesoffreespacealongthebackandsidesoftheunittoallowforproper
airflowand,therefore,moreevencoolingoftheproduct.
‐Whenloadingthetopshelf,avoidblockingtheevaporatorfan(s)(ifinstalled).Thereshould
beatleast4inchesofclearancebelowthefan(s)toallowproperairflow.
‐Donotoverloadtheunit.Afullloadisabout70to75%full.Additionally,theloadshouldbe
distributedevenlyfromtoptobottomandsidetosideforbestresults.
‐Minimizethetimethedoorisopen.Ontopoflettingthecoldairout,youarealsoletting
warm,moistairinwhichcanresultinmorecondensationand/orfrostintheunit.
Theauto‐defrostmodelswillperiodically(usually2to4timesaday)gointoadefrostcycleto
removefrostbuild‐uparoundtheevaporatorcoils.Duringthiscycle,thecompressoristurned
offanddefrostheatersareturnedonintheevaporatorsection.Thiswillcauseatemperature
transientwhichwillbeseeninairtemperatureinsidetheunitbutshouldnotsignificantlyaffect
producttemperatures.
Rememberthattheunitsarecalibratedtothedesigntemperaturerangebeforeleavingthe
factory.Wealsodoextensivetestingtoensurethatthesetemperatureswillresultinproduct
temperaturesinthedesiredband.Thereshouldbenoneedtoadjustthetemperaturecontrol
ontheseunits,butifitisnecessary,theycanbeadjustedusingthemanualthermostatonthe
insideoftheunit.
ItisSTRONGLYRECOMMENDEDthatyoucontactthemanufacturer’sTechnicalSupport
Departmentpriortoperforminganytemperatureadjustmentstoensuretheadjustmentis
necessaryand,ifso,itisperformedcorrectly.

7
QuickTroubleshootingGuide
Checktheseitemsbeforecallingforservice
PROBLEM: POSSIBLECAUSE/SOULTIONS:
Unitdoesnotrun
Electricalcircuitisnot110‐120V60Hz.
Thepowercordisnotpluggedin.
Nopoweratelectricaloutlet.Checktomakesure
breakerisnottrippedorfuseisnotblown.Additionally,
makesureunitisnotpluggedintoaGroundFaultCircuit
Interrupter(GFCI)typeofoutlet.
Unitdoesnotmaintainatthe
propertemperature
Checktheroomtemperature.Werecommendthe
refrigeratororfreezershouldbeplacedintheair
conditionedroombetween65°Fto85°F.Iftheroom
tempistoowarm,therefrigeratororfreezermaynotbe
abletomaintaintheinteriortempatproperrange.
Doorisnotclosedproperly.
Amountofstoredproductisoverloaded.
Productreplacementsarepushedagainstrearwallor
interruptedtheproperrefrigeratoraircirculation.For
theproperaircirculation,placetheproductsevenlyon
eachshelf.Donotpushagainsttherefrigerator’srearor
sidewalls.
Evaporatorisblockedbyfrostorice.Removethe
products,unplugtherefrigeratororfreezerpower,and
allowtheunittodefrost.Iftheproblemstillexists,call
forservice.
3rdpartythermometerisplacedincorrectly.Forproper
temperaturemonitoring,thethermometershouldbe
placeinthemiddleofrefrigerator.
Appliancerunstoolong
Prolongdooropenings.
Controlsettoocold.
Roomtemperatureishighwhichwillmaketheunitwork
hardertokeepcool.
Temperatureofexternalwall
surfaceiswarm
Theexteriorwallscanbeasmuchas30degreeswarmer
thanroomtemperatureduetotheembedded
condensercoils.Thisisnormalwhentheunitis
operating.

8
MoistureduringtheSummermonths
Theamountofmoisture,condensation,orhighhumidityrelatedissuesincreaseduringthesummer
and,inmostcases,willself‐resolvewhentheweathercoolsdown.Pleasenotearefrigeration
systemwillNOTgeneratemoistureorwaterbutsimplycondensesthemoisturethatisalreadyin
thechamber.Keepingtheunitinanairconditioned,lowhumidityspacewillresolvemanyissues.
Otherthingsyoushouldcheck:
1. Locationoftherefrigerator(SeeQuickTroubleshootingGuideabove)
2. Doorsealingandfrequencyofdooropeningevent(SeeQuickTroubleshootingGuideabove)
3. Makesurethereisawatertrap(U‐shapedloop)inthedraintubeneartheend.Thiswill
“trap”asmallamountofwaterintheloopandpreventairfromenteringthechamber
throughthetube.
BEFORECALLINGTHEMANUFACTURER’STECHNICALSUPPORTDEPARTMENT,pleasehavethe
unit’smodelandserialnumberreadyaswellastheproblemdescription.Themodelandserial
numberislocatedontheserialtagwhichcanbefoundontheinteriorleftupperwallofthe
unit.
PROBLEM:POSSIBLECAUSE/SOULTIONS:
Compressornoises
Compressormaybeoverheated.Pleasechecktheroom
tempandensuretherangeiswithin65°Fto85°F.Ifthe
problemstillexists,callforservice.
Moisturecollectsinside
Doorgasketisnotsealingproperly.Checkfordebris,
cracks,anditemspassingthroughdooratthegasket.
Therefrigeratororfreezerisfacingadoorwayoris
underneathofairconditioningvent.Relocatetheunitor
redirectairvent.
Toomanydooropenings.Minimizetimedoorisopen.
Hot,humidweatherincreasescondensation.
Makesurethereisawatertrap(U‐shapedloop)inthe
draintubenearthecompressor.Thiswill“trap”asmall
amountofwaterintheloopandpreventairfrom
enteringthechamberthroughthetube.
Moisturecollectsonoutside
surface
Hot,humidweatherincreasescondensation.
Ashumiditydecreases,moisturewilldisappear.
Odorinsidetheunit
Interiorneedstobecleaned.Seesectionon
maintenanceandcleaninginthismanual.
Makesureproductcontainersaretightlysealedto
preventleakage
Doorwillnotclose
Theunitisnotlevel.RefertotheLevelingsectionatthe
beginningofthismanual
Checkfordirtanddebrisoritemspassingthroughthe
doorseal.

9
MaintenanceandCleaning
Manual‐DefrostUnitsshouldbedefrostedandcleanedwhenever¼to½inchoffrosthasaccumulated
aroundtheevaporatorcoilsoriftheunitwillnotmaintainpropertemperature.Usetheproceduresin
theDefrostingsectionatthebottomofthispage
AutoDefrostunitsrequirelittlemaintenance.Theyshouldbecleanedperiodicallytokeepthemrunning
efficiently.Usethecleaningagentsandsuggestionsinthistableforbestresults.
CLEANING
PARTCLEANINGAGENTSTIPSANDPRECAUTIONS
InteriorandDoor
Liners
Soapandwater
Bakingsodaandwater
Use2tablespoonsofbakingsodain1quartof
warmwater
Besuretowringexcesswateroutofspongeor
clothbeforecleaningaroundcontrols,lightbulb
oranyelectricalparts.
GlassDoors(if
applicable)
SoapandwaterCleantheglasswithamilddetergentandwater
onasoftclothorsponge.Rinsewithwaterand
wipedry
DoorGasketsSoapandwaterWipegasketsandtheirseatingsurfaceswitha
cleansoftcloth
ShelvesSoapandwaterDonotwashremovableshelvesindishwasher
Exteriorand
Handles
Soapandwater
NonAbrasiveGlass
Cleaner
Donotusecommercialhouseholdcleaners,
ammonia,oralcoholtocleanhandles
Useasoftclothtocleansmoothhandles
Donotuseadryclothtocleansmoothhandles
DEFROSTING(LABH‐3‐RFCM,LABH‐12‐RFCM,LABH‐16‐RFCMONLY)
Itisimportanttodefrostandcleantheunitwhen¼to½inchoffrosthasaccumulatedaround
theevaporatorcoilsorwhentheunitwillnotmaintainpropertemperature.Whendefrosting
becomesnecessary,turntheunitoffbydisconnectingitfromthepowersource.DONOT
ADJUSTTHETHERMOSTAT.Removetheproductandleavethedooropenwhiledefrostingthe
evaporator.Thefrostshouldmeltanddrainthroughthedraintubetothedrainpanunderthe
unit.Oncetheunitisdefrosted,cleanitusingthecleaningsuggestionsinthetableabove.
WipeawayanyexcesswaterandreturntheunittoservicepertheRefrigerationOperation
sectionofthismanual.

10
PRODUCTWARRANTYINFORMATION
HORIZONSCIENTIFIC,INC.PRODUCTWARRANTY
HorizonScientific,Inc.warrantstotheoriginalpurchasereverynewHorizonScientific,Inc.refrigeratedunit,the
cabinetandallpartsthereof,tobefreefromdefectsinmaterialorworkmanship,whensuchunitisinstalled,used,
andmaintainedinaccordancewithprovidedinstructions,foraperiodoftwo(2)years.Thewarrantyperiodstarts
twoweeksfromthedateofshipmentfromHorizonScientific,Inc.Thistwoweekperiodallowsampleshipping
timesothatthewarrantywillgointoeffectatapproximatelythesametimeyourequipmentisdelivered.Unless
subjecttopriorwrittenagreementwithHorizonScientific,Inc.,thiswarrantydoesnotallowforanywarrantystart
defermentgreaterthantwoweeksfromdateofshipmentduetoadelayedinstallationand/orstart‐up.By
purchasinganyproductfromHorizonScientific,Inc.,youandanyentityforwhichyouarepurchasingacknowledge
andagreetoeachandeveryprovisioncontainedherein,andallotherNoticesandTermsprovidedtoPurchaserby
HorizonScientific,Inc.,whichareherebyincorporated.
Underthiswarranty,HorizonScientific,Inc.,throughitsauthorizedserviceorganizations,willrepair,oratits
option,replaceanypartfoundtocontainamanufacturingdefectinmaterialorworkmanshipwithoutchargeto
theownerforparts,servicelabororanyshippingorcartagecosts.Replacementorrepairedpartswillbe
warrantedforonlytheunexpiredportionoftheoriginalwarranty.
ADDITIONALTHREEYEARCOMPRESSORWARRANTY
Inadditiontothetwo(2)yearwarrantystatedabove,HorizonScientific,Inc.warrantsitshermeticallyandsemi‐
hermeticallysealedcompressorstobefreefromdefectsinbothmaterialandworkmanshipundernormaluseand
serviceforaperiodofthree(3)additionalyearsfromtheendoftheinitialtwo(2)yearwarrantyperiod,butnotto
exceedfive(5)yearsaftershipmentfromHorizonScientific,Inc.
CompressorsdeterminedbyHorizonScientific,Inc.tohavebeendefectivewithinthisextendedtimeperiodwill,at
HorizonScientific,Inc.'soption,beeitherrepairedorreplacedwithacompressororcompressorpartsofsimilar
designandcapacity.
Thethree(3)yearextendedcompressorwarrantyappliesonlytohermeticallyandsemi‐hermeticallysealedparts
ofthecompressoranddoesnotapplytoanyotherpartsorcomponents,including,butnotlimitedto,cabinet,
paintfinish,temperaturecontrol,refrigerant,meteringdevice,driers,motorstartingequipment,fanassemblyor
anyotherelectricalcomponents.
HorizonScientific,Inc.’ssoleobligationunderthiswarrantyislimitedtoeitherrepairorreplacementofparts,
subjecttotheadditionallimitationsbelow.Thiswarrantyneitherassumesnorauthorizesanypersontoassume
obligationsotherthanexpresslycoveredbythiswarranty.
NOCONSEQUENTIALDAMAGES.HorizonScientific,Inc.isnotresponsibleforeconomicloss;profitloss;orspecial,
indirectorconsequentialdamages,includingwithoutlimitation,lossesordamagesarisingfromcontentsspoilage
claimswhetherornotonaccountofrefrigerationfailure,electricalfailure,powerfailure,orcompressorfailure.

11
HORIZONSCIENTIFIC,INC.’SMAXIMUMCUMULATIVELIABILITYRELATIVETOALLCLAIMSANDLIABILITIES,
INCLUDINGOBLIGATIONSUNDERANYINDEMNITY,WHETHERORNOTINSURED,SHALLNOTEXCEEDTHECOSTOF
THEPRODUCT(S)GIVINGRISETOTHECLAIMORLIABILITY.
WARRANTYISNOTTRANSFERABLE.Thiswarrantyisnotassignableandappliesonlyinfavoroftheoriginal
purchaser/usertowhomdelivered.Anysuchassignmentortransfershallvoidthewarrantieshereinmadeand
shallvoidallwarranties,expressorimplied,includinganywarrantyofmerchantabilityorfitnessforaparticular
purpose.
NOIMPLIEDWARRANTYOFMERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE.Therearenoother
warranties,express,implied,orstatutory,exceptthetwo(2)yearwarrantyandtheadditionalthree(3)year
compressorwarrantyasdescribedabove.Thesewarrantiesareexclusiveandinlieuofallotherwarranties,
includingimpliedwarrantyandmerchantabilityorfitnessforaparticularpurpose.Therearenowarrantieswhich
extendbeyondthedescriptiononthefacehereof,whetherbasedoncontract,warranty,tort(including
negligence),strictliability,indemnity,oranyotherlegaltheory,andwhetherarisingoutofwarranties,
representations,instructions,installations,ornon‐conformitiesfromanycause.Purchaserfurtheracknowledges
thatthepurchasepriceoftheProductreflectsthesewarrantytermsandremedies.
ALTERATION,NEGLECT,ABUSE,MISUSE,ACCIDENT,DAMAGEDURINGTRANSITORINSTALLATION,FIRE,
FLOODOROTHEREXTERNALCAUSES.
HorizonScientific,Inc.isnotresponsiblefortherepairorreplacementofanypartsthatHorizonScientific,Inc.
determineshavebeensubjectedafterthedateofmanufacturetoalteration,neglect,abuse,misuse,accident,
damageduringtransitorinstallation,fire,floodorotherexternalcauses.Itdoesnotapplytodefectsresulting
fromfailuretoproperlyinstall,operateormaintaintheproductinaccordancewiththeprintedinstructions
provided,ordamagecausedbythestorageofanycorrosivematerialthatcomesincontactwiththeinterioror
exteriorportionsofthecabinet,ortheuseofsparkproducingequipmentorcontainers(suchasgalvanizedor
carbonizedsteelcontainers)thatcomeincontactwithanyinteriorportionofthecabinet.
OUTSIDEU.S./CANADA.Thiswarrantydoesnotapplyto,andHorizonScientific,Inc.isnotresponsiblefor,any
warrantyclaimsmadeonproductssoldorusedoutsidetheUnitedStatesandCanada.
CHOICEOFLAW/VENUE.ThelawsoftheStateofSouthCarolinashallgovernthevalidity,interpretationand
enforcementofthiswarranty,regardlessofconflictsoflawprinciples.Purchaseragreesthatpropervenueforany
actiontoenforcethetermsofthiswarrantyshallbetheDorchesterCountyDistrictCourts,SouthCarolina.
PurchasersubmitsthejurisdictionofsuchcourtsoverthePurchaserandthesubjectmatterofanysuchaction.
Anyactionforbreachofthesewarrantyprovisionsmustbecommencedwithinone(1)yearafterthatcauseof
actionhasaccrued.
WARRANTYCLAIMS.Toobtainpromptwarrantyservice,simplycontactthemanufacturerat800‐648‐4041.
HorizonScientific,Inc.’sshippingrecordsshowingdateofshipmentshallbeconclusiveinestablishingthewarranty
period.Allclaimsshouldinclude:modelnumberoftherefrigerator,theserialnumberofthecabinet,proofof
purchase,dateofinstallation,andallpertinentinformationsupportingtheexistenceoftheallegeddefect.Any
repairsmustbeauthorizedbyHorizoninorderforthewarrantytobehonored.
This manual suits for next models
6
Table of contents
Other LabRepCo Refrigerator manuals