LAMINOX Saluber PD23E-20 User manual

OPERATION MANUAL
DEHUMIDIFIER
Saluber PD23E-20
Thanks for choosing this dehumidier, before using. Please read this
manual carefully, and follow this manual strictly. Please keep it
properly after reading for future reference.

DIRECTORY
IMPORTANT SAFEGUARDS
SPECIFICATIONS
GENRERAL DESCRIPTION
CONTROL PANEL
CONTROL PANEL
EMPTTING THE WATER TANK
CONTINUOUS DRAINAGE OPERATION
REPLACEMENT AND MAITENANCE OF AIR FILTER
CARE AND CLEANING
FAULT CODE
03
04
05
06
07
08
08
08
10
12
OTHER NOTICE 09
TROUBLE SHOOTING 13
02
DEHUMIDIFIER
Saluber PD23E-20
01
To prevent damage and voiding your warranty. Please place the unit in its right
position for a minimum of two hours before operating. For best result from your
portable dehumidifier please read this instruction manual carefully and save it for
future refer ence.
IMPORTANT NOTICE

Cleaning and user maintenance shall not be made by children without supervision.
The refrigerant in this unit with a uorinated greenhouse gas covered by the Kyoto
Protocol, which dangerous for the environment and for the global warming if it is
enters into atmosphere.
Chemical name of refrigerant (R-134a) is a uorinated greenhouse gas covered by the
Kyoto Protocol, Its global warming potential(GWP) is the 1430.
d)
e)
The ambient temperature operating range is between 5℃ and 35℃ with a relative
humidity ranging from 30% to 80%. For maximum efciency use the unit between 15℃
and 32℃.
SPECIFICATIONS
0403
When using electrical appliances, basic safety precautions should always be
followed including the following:
※If the machine`s power supply cord is damaged, you must entrust the
manufacturers of the machine. Maintenance service center or qualified
technicians will change for you, in case of any danger.
Leave the appliance to stand for at least two hours before power on, especially after
transportation.
Make sure that the voltage matching with the relevant data indicated on the rating
label.
The socket must be with grounding.
Keep the appliance dry. Make sure no water on the top or the body.
Do not unpin the plug when the appliance is working.
If moving needed, please switch it off and unpin the plug.
Allow a free space of 15 cm around air inlet of the appliance.
Do not insert any object into the air inlet or outlet openings.
Do not place the dehumidifier near a heating source (esp. a radiator) or indirect
sunlight.
Ensure that the appliance does not become hot.
Empty the water tank regularly. (In extreme conditions the water tank may be full
after a few hours operation.) Clean the air inlet lter if it becomes contaminated: the
appliance is most effective when
the lter is clean.
Please do not expect the air dehumidier to be effective when too many doors or
windows are opened or when something in the room is producing a lot of humidity.
The air dehumidifier will come into effect immediately. However, the reduction of
humidity many hardly be measureable during the rst few days.
If the supply cord is damaged, it must be replaced by the manufacturer, its servuce
agent
or similarly qualied persons in order to avoid a hazard.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
konwledge if they have beeen given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
a)
b)
c)
IMPORTANT SAFEGUARDS
Rated freguency:
Max power input:
Rated input power:
Tank capacity:
Air volume:
Noise level:
Refrigerant:
Net weight:
Suction pressure:
Discharge pressure:
Saluber PD23E-20
20 L/Day(30℃RH80%)
9.5 L/Day(26.7℃RH60%)
AC 220-240V
50 Hz
370W
240W
4 L
180m³/h
42 dB(A)
R134a /160g
14.3kg
0.5MPa
1.5MPa
Model No.:
Dehumidify capacity:
Rated voltage:

06
CONTROL PANEL
05
GENRERAL DESCRIPTION
7. Air inlet
8. Water tank
1. Oscillation louver
3. Air outlet
4. Lamp
2. Control panel
6. Handle
5. Wheels
9. UV-lamp
10. Prelter/activated coal lter
11. Continuous drain port
12. Back cover
13. Power cord
Operation indicator
Water full
indicator
Defrost indicator
Lamp
Down keyUp key
Mode
Timer
Power
P0WER
Starts or Stops
appliance.
MODE Control
Select the functions
of the unit for:AUTO
/ HIGH / LOW / and
FAN. The appliance
will go. AUTO
function the rst time
it is switched on and
remains in this mode
until other type of
programming is
chosen. Depending
on your relative
humidity conditions,
turn the fan speed
switch to high or low.
FAN (Ventilation Key)
FAN(Ventilation Key): press "MODE" key to select "FAN", and "FAN"
indicator light comes on.
LAMP
Start the appliance, the lamp will turn on automatically. The lamp color will
change according to the humidity condition (with 100 seconds as interval
between color changing)
Red color means high humidity, RH≥80%
Green color means comfortable, 80%>RH≥60%
Orange color means dry, RH<60%
Press ”LAMP” key, the lamp will be off or on.

08
Empty the water tank regularly when full, the air
dehumidifier turns off automatically and the tank full
indicator is turned on.
When used regularly, the lter may become clogged
with dust and particles. Therefore the lter should be
cleaned every one or two weeks. Follow these steps:
1. Remove the lter by pulling it out carefully.
2. Clean the filter with a vacuum cleaner or with
water. Tap the lter to remove excess water and let it
dry completely. Once you make sure that your filter
is completely dry, re-install it on your device. Do not
wash your lter in the dishwasher and never use hair
dryers or
Your device has a drainage port that allows you to have continuous drainage. Connect
a 10mm diameter PVC pipe (optional - not provided in the package) with the drainage
port located on back part of the unit, for continuous drainage purpose, as below
gure. Ensuring the hose is directed downwards, allowing water to ow by gravity to
an external drain. Ensure that the end of the hose is lower than the drain opening,
otherwise the water will not drain and ooding may occur.
Open the front cover of your device
Hold the water tank by its handle
Pull it out carefully
Empty the water tank
Return the empty water tank to its position after
wiping it off from any water residue.
EMPTYING THE WATER TANK
CONTINUOUS DRAINAGE OPERATION
REPLACEMENT AND MAINTENANCE
OF AIR FILTER
07
HUMIDITY SETTING
Press UP / DOWN key to select the desired relative humidity level,
default relative humidity is 55%. Relative humidity 35% is selected, the
compressor will not stop until water tank full.
TIMER (timer function)
press timer to program time and "TIMER" light comes on while timer is
programmed. Befpre programming make sure that the timer function has
not been actived (the light must be off)! The following timer programs are
available.
a) Delayed power-on function (the appliance is in stand-by status) USE
key "UP" and "DOWN" to set the time period (0~24 hours) The appliance
will start once time reaches setting value.
b) Delayed power-off function (the appliances is in working stantus) The
appliance will stop once time reach setting value.
DEFROST
The appliance will defrost automatically as programmed once the
coil sensor detects temperatue below some figure, and the defrosting
indicator will light up at the same time. Once defrosting finishes, the
appliance will recover to previous running mode.
TANK-FULL
If the water tank is full, the indicator light comes on and ash.
Carbon lter(deodor function)
Take out the carbon lter from bag and insert
it on the lter. See picture below. Suggest to
change the carbon filter every 3 months, it
always keep the room fresh.
CONTROL PANEL

10
Do not put the body in the
soft, uneven ground, in order
to avoid vibration or sound.
Do not put heavy or water
body above the vase, items.
Clean the body, gently
wipe with a damp cloth, do
not splash water, to avoid
damage to electrical
insulation
Please close the doors and
windows when used to
achieve the effect of the
desiccant.
Do not use any fine rod,
hard object into the body, so
as to avoid failure or danger.
Please stay away from the
fuselage. The heat source
side heaters to avoid danger
and waste electricity
CARE AND CLEANING
09
1.The machine uses the temperature range of 5℃~35℃, please use the machine in
this scope, (otherwise it will start the protection action, causing the machine
automatically stop running.)
2. At room temperature at 5℃ and the absolute temperature of the environment is very
low. It is not necessary to use the machine.
3. When the machine is running, it will produce a small portion of the heat, the room
temperature
will be a little higher, this is a normal phenomenon, please feel at ease.
4. automatically stop running, please send the water in the water drained, and put back
to the water tank, the machine will continue to operate.
5. In order to ensure the normal operation, do not open the water tank oat cover, or
place any
foreign body in the water tank.
6. When the machine can not start or unknown cause, please check with the following
steps:
(1) check whether the plug or the power cord is normal.
(2) Above all is normally, just please re-start the machine after 10 minute.
(3) If you are still unable to start, please contact the local dealer or the company's
customer service department.
7. Air inlet and outlet and the distance between the adjacent material to keep 15 cm
above.
8. After the machine is stopped, please restart in ve minutes to make sure that the
machine is used for longer service life.
9. if the long time does not use the desiccant, please unplug the power plug.
10. the machine inlet frosting, automatically defrost.
GENRERAL DESCRIPTION

12
E1 Room temperature (ambient temperature) sensor for short circuit
Code
E2
E3
E4
E5
E6
Failure
Room temperature sensor open circuit
Humidity sensor short circuit
Humidity sensor open circuit
Coil sensor short circuit
Coil sensor open circuit
CARE AND CLEANING
11
Please clean filter once every
two weeks (not to use 40
degrees above the hot water
or alcohol, gasoline, toluene
and other dangerous
flammable liquid).
Power failure or long-term
nouse, please unplug the
power cable plug, so as to
avoid leakage, and fire.
Around the body or out of
the air outlet do not put
items, to ensure that the
effect of the desiccant air.
When not in use, please
put in the position of
ventilation, and unplug the
power plug to avoid
danger.
After filtering the net, please
do not dry in the sun, so as
not to deformation.
Before your moving the
machine, pour out the water
within the water tank

When the following problems occur, please contact the local seller or customer service:
1) When the fuse breaks
2) When water or other dirt get's into the machine
3) When the power line or plug is abnormally hot.
When you need to call the customer services
Anything Wrong?
……, Please check your machine with the following steps
(only the service person can open the side door)
ISSUES Please check as following
The operation switch is
“ON”,but the machine is
not operation.
1. Is the water tank placed in the right position?
2. Is the power plug inserted right position?
3. Is the fuse broken?
4. Is the power off?
The dehumidification
amount is too low.
1. Is the front lter net dirty?
2. Is the interior temperature and the humidity too low?
3. Is the air outlet and air inlet jammed?
Long time operation can
not reach the suitable
humidity condition.
1. Does the door or window too widely open?
2. Is there any generated water evaporator?
3. Is the interior space too big?
When the machine is
making huge noise.
1. Is the oor at and hard?
2. Is the dehumidier in the right position?
The lamp is continuously
on.
1. Is the temperature or humidify sensor is
damaged or loosen?
TROUBLE SHOOTING
13

Table of contents