Laney LX120RTWIN User manual

LX120RWN
TI
OPERATING INSTRUCTIONS - 1
USER MANUAL

L10X 2RTWIN
22
L 1 0
X 2 RTWIN
33
Laney Laney
IMPORTANT SAFETY INSTRUCTIONS
WARNING: When using electric products, basic cautions should always be followed, including the following.
1. Read all safety and operating instructions before using this product
2. The product should be powered by a three pin `grounded (or earthed) plug connected to a power socket with a grounded earth outlet.
3. All safety and operating instructions should be retained for future reference
4. Obey all cautions in the Operating instructions and on the back of the unit
5. All operating instructions should be followed
6. This product should not be used near water, i.e. a bathtub, sink, swimming pool, wet basement, etc.
7. This product should be located so that its position does not interfere with its proper ventilation. It should not be placed flat against a wall or placed in a built
up enclosure that will impede the flow of cooling air.
8. This product should not be placed near a source of heat such as stove, radiator, or another heat producing amplifier.
9. Connect only to a power supply of the type marked on the unit adjacent to the power supply cord.
10.Never break off the ground pin on a power supply cord.
11.Power supply cords should always be handled carefully. Never walk or place equipment on power supply cords. Periodically check cords for cuts or signs of
stress, especially at the plug and the point where the chord exits the unit.
12.The power supply cord should be unplugged when the unit is to be unused for long periods of time.
13.If this product is to be mounted in an equipment rack, rear support should be provided.
14.The user should allow easy access to any mains plug, mains coupler and mains switch used in conjunction with this unit thus making it readily operable.
15.Metal parts can be cleaned with a damp cloth. The vinyl covering used on some units can be cleaned with a damp cloth or ammonia based household cleaner if
necessary. Disconnect the unit from the power supply before cleaning.
16.Care should be taken so that objects do not fall and liquids are not spilled into the unit through any ventilation holes or openings. On no account place drinks
on the unit.
17.A qualified service technician should check the unit if:
18.The user should not attempt to service the equipment. All service work is done by a qualified service technician.
19. Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in
susceptibility to noise induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently
intense noise for a sufficient time. The U.S. Government's Occupational Safety and Health Administration (OSHA) has
specified the following permissible noise level exposure. (See oposite).
According to OSHA, any exposure in excess of the permissible limits could result in some hearing loss. Ear plugs
or protectors in the ear canals or over the ears must be worn when operating this amplification system in order to
prevent a permanent hearing loss if exposure exceeds the limits set forth above. To ensure against potentially
dangerous exposure to high sound pressure levels it is recommended that all persons exposed to equipment capable
of producing high sound pressure levels such as this amplification system be protected by hearing protectors while this
unit is in operation.
!The power cord has been damaged
!Anything has fallen or spilled into the unit
!The unit does not appear to operate correctly
!The unit has been dropped or the enclosure damaged.
Duration Per Day
In Hours
8
6
4
3
2
1 ½
1
½
¼ or less
Sound Level dBA,
slow response
90
92
95
97
100
102
105
110
115
SAVE THESE INSTRUCTIONS
BEFORE SWITCHING ON
After unpacking your amplifier check that it is factory fitted with a three pin
'grounded' (or earthed) plug. Before plugging into the power supply ensure
you are connecting to a grounded earth outlet.
If you should wish to change the factory fitted plug yourself, ensure that the
wiring convention applicable to the country where the amplifier is to be used is
strictly conformed to. As an example in the United Kingdom the cable colour
code for connections are as follows.
NOTE
This manual has been written for easy access of information. The front and
rear panels are graphically illustrated, with each control and feature
numbered. For a description of the function of each control feature, simply
check the number with the explanations adjacent to each panel.
Your Laney amplifier has undergone a thorough two stage, pre-delivery
inspection, involving actual play testing.
When you first receive your Laney guitar amplifier, follow these simple
procedures:
(i) Ensure that the amplifier is the correct voltage for the country it is to be
used in.
ii) Connect your instrument with a high quality shielded instrument cable.
You have probably spent considerable money on your amplifier and guitar -
don’t use poor quality cable it won’t do your gear justice.
Please retain your original carton and packaging so in the unlikely event
that some time in the future your amplifier should require servicing you will
be able to return it to your dealer securely packed.
Care of your Laney amplifier will prolong it's life.....and yours!
EARTH or GROUND GREEN/YELLOW
NEUTRAL - BLUE
LIVE - BROWN
CAUTION:
WARNING:
Intended to alert the user to the presence of uninsulated ‘Dangerous Voltage’ within the products
enclosure that may be sufficient to constitute a risk of electrical shock to persons.
Ce symbole est utililise pur indiquer a l’utilisateur de ce produit de tension non-isolee dangereuse
pouvant etre d’intensite suffisante pour constituer un risque de choc electrique.
Este simbolo tiene el proposito de alertar al usuario de la presencia de ‘(voltaje) peligroso’ que no
tiene aislamiento dentro de la caja del producto que puede tener una magnitud suficiente como
para constituir riesgo de corrientazo.
Dieses Symbol soll den Anwender vor unsolierten gefahrlichen Spannungen innerhalb des
Gehauses warnen, die von Ausrichender Starke sind, um einen elektrischen Schlag verursachen
zu konnen.
Intended to alert the user of the presence of important operating and maintenance (Servicing)
instructions in the literature accompanying the product.
Dieses Symbol soll den Anwender vor unsolierten gefahrlichen Spannungen innerhalb des
Gehauses warnen, die von Ausrichender Starke sind, um einen elektrischen Schlag verursachen
zu konnen.
Este simbolo tiene el proposito de la alertar al usario de la presencis de instrucccones importantes
sobre la operacion y mantenimiento en la literatura que viene conel producto.
Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung
aufmerksam machen, die Handhabung und Wartung des Produkts betreffen.
Risk of electrical shock - DO NOT OPEN.
To reduce the risk of electrical shock, do not remove the cover. No user serviceable parts inside.
Refer servicing to qualified personnel.
Risques de choc electrique - NE PAS OUVIRIR
Afin de reduire le risque de choc electrique, ne pas enlever le couvercle. II ne se trouve a l’interieur
aucune piece pouvant etre reparee par l’utilisateur. Confier l’entretien a un personnel qualifie.
Riesgo de corrientazo - no abra
Para disminuir el risego de carrientazo, no abra la cubierta. No hay piezas adentro que el pueda
reparar. Deje todo mantenimiento a los tecnicos calificadod.
Risiko - Elektrischer Schlag! Nicht offen!
Um das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es
befinden sich keine Teile darin, die vom Anwender repariert werden Konnten. Reparaturen nur von
qualifiziertem Fachpersonal durchfuhren lassen.
To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before
using this appliance please read the operating instructions for further warnings.
Afin de prevenir les risques de decharge electrique ou de feu, n’exposez pas cet appareil a la pluie
ou a l’humidite. Avant d’utiliser cet appareil, lisez les advertissments supplentaires situes dans le
guide.
Para evitar corrientazos o peligro de incendio, no deja expuesto a la lluvia o humedad este
aparato Antes de usar este aparato, lea mas advertcias en la guia de operacion.
Um einen elektrischen Schalg oder Feuergefahr zu vermeiden, sollte dieses Gerat nicht dem
Regen oder Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die
Bedienungsanleitung lesen.
PRECAUCION:
ADVERTENCIA:
ATTENTION:
ADVERTISSEMENT:
VORSICHT:
ACHTUNG:

L10INX 2RTW
22
L 1 0X 2 RTWIN
33
Laney Laney
IMPORTANT SAFETY INSTRUCTIONS
WARNING: When using electric products, basic cautions should always be followed, including the following.
1. Read all safety and operating instructions before using this product
2. The product should be powered by a three pin `grounded (or earthed) plug connected to a power socket with a grounded earth outlet.
3. All safety and operating instructions should be retained for future reference
4. Obey all cautions in the Operating instructions and on the back of the unit
5. All operating instructions should be followed
6. This product should not be used near water, i.e. a bathtub, sink, swimming pool, wet basement, etc.
7. This product should be located so that its position does not interfere with its proper ventilation. It should not be placed flat against a wall or placed in a built
up enclosure that will impede the flow of cooling air.
8. This product should not be placed near a source of heat such as stove, radiator, or another heat producing amplifier.
9. Connect only to a power supply of the type marked on the unit adjacent to the power supply cord.
10.Never break off the ground pin on a power supply cord.
11.Power supply cords should always be handled carefully. Never walk or place equipment on power supply cords. Periodically check cords for cuts or signs of
stress, especially at the plug and the point where the chord exits the unit.
12.The power supply cord should be unplugged when the unit is to be unused for long periods of time.
13.If this product is to be mounted in an equipment rack, rear support should be provided.
14.The user should allow easy access to any mains plug, mains coupler and mains switch used in conjunction with this unit thus making it readily operable.
15.Metal parts can be cleaned with a damp cloth. The vinyl covering used on some units can be cleaned with a damp cloth or ammonia based household cleaner if
necessary. Disconnect the unit from the power supply before cleaning.
16.Care should be taken so that objects do not fall and liquids are not spilled into the unit through any ventilation holes or openings. On no account place drinks
on the unit.
17.A qualified service technician should check the unit if:
18.The user should not attempt to service the equipment. All service work is done by a qualified service technician.
19. Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in
susceptibility to noise induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently
intense noise for a sufficient time. The U.S. Government's Occupational Safety and Health Administration (OSHA) has
specified the following permissible noise level exposure. (See oposite).
According to OSHA, any exposure in excess of the permissible limits could result in some hearing loss. Ear plugs
or protectors in the ear canals or over the ears must be worn when operating this amplification system in order to
prevent a permanent hearing loss if exposure exceeds the limits set forth above. To ensure against potentially
dangerous exposure to high sound pressure levels it is recommended that all persons exposed to equipment capable
of producing high sound pressure levels such as this amplification system be protected by hearing protectors while this
unit is in operation.
!The power cord has been damaged
!Anything has fallen or spilled into the unit
!The unit does not appear to operate correctly
!The unit has been dropped or the enclosure damaged.
Duration Per Day
In Hours
8
6
4
3
2
1 ½
1
½
¼ or less
Sound Level dBA,
slow response
90
92
95
97
100
102
105
110
115
SAVE THESE INSTRUCTIONS
BEFORE SWITCHING ON
After unpacking your amplifier check that it is factory fitted with a three pin
'grounded' (or earthed) plug. Before plugging into the power supply ensure
you are connecting to a grounded earth outlet.
If you should wish to change the factory fitted plug yourself, ensure that the
wiring convention applicable to the country where the amplifier is to be used is
strictly conformed to. As an example in the United Kingdom the cable colour
code for connections are as follows.
NOTE
This manual has been written for easy access of information. The front and
rear panels are graphically illustrated, with each control and feature
numbered. For a description of the function of each control feature, simply
check the number with the explanations adjacent to each panel.
Your Laney amplifier has undergone a thorough two stage, pre-delivery
inspection, involving actual play testing.
When you first receive your Laney guitar amplifier, follow these simple
procedures:
(i) Ensure that the amplifier is the correct voltage for the country it is to be
used in.
ii) Connect your instrument with a high quality shielded instrument cable.
You have probably spent considerable money on your amplifier and guitar -
don’t use poor quality cable it won’t do your gear justice.
Please retain your original carton and packaging so in the unlikely event
that some time in the future your amplifier should require servicing you will
be able to return it to your dealer securely packed.
Care of your Laney amplifier will prolong it's life.....and yours!
EARTH or GROUND GREEN/YELLOW
NEUTRAL - BLUE
LIVE - BROWN
CAUTION:
WARNING:
Intended to alert the user to the presence of uninsulated ‘Dangerous Voltage’ within the products
enclosure that may be sufficient to constitute a risk of electrical shock to persons.
Ce symbole est utililise pur indiquer a l’utilisateur de ce produit de tension non-isolee dangereuse
pouvant etre d’intensite suffisante pour constituer un risque de choc electrique.
Este simbolo tiene el proposito de alertar al usuario de la presencia de ‘(voltaje) peligroso’ que no
tiene aislamiento dentro de la caja del producto que puede tener una magnitud suficiente como
para constituir riesgo de corrientazo.
Dieses Symbol soll den Anwender vor unsolierten gefahrlichen Spannungen innerhalb des
Gehauses warnen, die von Ausrichender Starke sind, um einen elektrischen Schlag verursachen
zu konnen.
Intended to alert the user of the presence of important operating and maintenance (Servicing)
instructions in the literature accompanying the product.
Dieses Symbol soll den Anwender vor unsolierten gefahrlichen Spannungen innerhalb des
Gehauses warnen, die von Ausrichender Starke sind, um einen elektrischen Schlag verursachen
zu konnen.
Este simbolo tiene el proposito de la alertar al usario de la presencis de instrucccones importantes
sobre la operacion y mantenimiento en la literatura que viene conel producto.
Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung
aufmerksam machen, die Handhabung und Wartung des Produkts betreffen.
Risk of electrical shock - DO NOT OPEN.
To reduce the risk of electrical shock, do not remove the cover. No user serviceable parts inside.
Refer servicing to qualified personnel.
Risques de choc electrique - NE PAS OUVIRIR
Afin de reduire le risque de choc electrique, ne pas enlever le couvercle. II ne se trouve a l’interieur
aucune piece pouvant etre reparee par l’utilisateur. Confier l’entretien a un personnel qualifie.
Riesgo de corrientazo - no abra
Para disminuir el risego de carrientazo, no abra la cubierta. No hay piezas adentro que el pueda
reparar. Deje todo mantenimiento a los tecnicos calificadod.
Risiko - Elektrischer Schlag! Nicht offen!
Um das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es
befinden sich keine Teile darin, die vom Anwender repariert werden Konnten. Reparaturen nur von
qualifiziertem Fachpersonal durchfuhren lassen.
To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before
using this appliance please read the operating instructions for further warnings.
Afin de prevenir les risques de decharge electrique ou de feu, n’exposez pas cet appareil a la pluie
ou a l’humidite. Avant d’utiliser cet appareil, lisez les advertissments supplentaires situes dans le
guide.
Para evitar corrientazos o peligro de incendio, no deja expuesto a la lluvia o humedad este
aparato Antes de usar este aparato, lea mas advertcias en la guia de operacion.
Um einen elektrischen Schalg oder Feuergefahr zu vermeiden, sollte dieses Gerat nicht dem
Regen oder Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die
Bedienungsanleitung lesen.
PRECAUCION:
ADVERTENCIA:
ATTENTION:
ADVERTISSEMENT:
VORSICHT:
ACHTUNG:

Dear Player,
Thank you very much for purchasing your new Laney product and becoming part of the worldwide Laney family. Each and
every Laney unit is designed and built with the utmost attention to care and detail, so I trust yours will give you many years of
enjoyment.
Laney products have a heritage which stretches back to 1967 when I first began building valve amplifiers in my parent’s garage.
Since then we have moved on from strength to strength developing an extensive range of guitar, bass, public address and
keyboard amplification products along with a list of Laney endorsees that includes some of the world’s most famous and
respected musicians. At the same time we believe we have not lost sight of the
reason Laney was founded in the first place - a dedication to building great
sounding amplification for working musicians.
Warm Regards,
Lyndon Laney CEO
Laney
L10X 2RTWIN
44
Laney
L 1 0
X 2 RTWIN
55
INTRODUCTION
The LX120RTwin is a 120W open back twin channel guitar combo loaded with
twin 12 inch loudspeakers. It features two completely separate channels, each with bass, mid and treble EQ controls; and
the drive channel is also loaded with our custom XTS technology. It also features an extension speaker socket to drive
additional cabinets and a CD/Line in socket should you need to play along to a CD/MP3; FX loop sockets for your external
FX processors; and finally the LX120RTwin features a built in spring line reverb with master level control.
We hope you enjoy using your LX120RTwin as much as we enjoyed designing and making it.
Best wishes from all at Laney.
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
EXTREME/METAL
CLEAN
BLUES
ROCK LEAD
IN
IN
IN
OUT
QUICK START SETTINGS - Suggestions only experiment!

Dear Player,
Thank you very much for purchasing your new Laney product and becoming part of the worldwide Laney family. Each and
every Laney unit is designed and built with the utmost attention to care and detail, so I trust yours will give you many years of
enjoyment.
Laney products have a heritage which stretches back to 1967 when I first began building valve amplifiers in my parent’s garage.
Since then we have moved on from strength to strength developing an extensive range of guitar, bass, public address and
keyboard amplification products along with a list of Laney endorsees that includes some of the world’s most famous and
respected musicians. At the same time we believe we have not lost sight of the
reason Laney was founded in the first place - a dedication to building great
sounding amplification for working musicians.
Warm Regards,
Lyndon Laney CEO
Laney
L10INX 2RTW
44
Laney
L 1 0X 2 RTWIN
55
INTRODUCTION
The LX120RTwin is a 120W open back twin channel guitar combo loaded with
twin 12 inch loudspeakers. It features two completely separate channels, each with bass, mid and treble EQ controls; and
the drive channel is also loaded with our custom XTS technology. It also features an extension speaker socket to drive
additional cabinets and a CD/Line in socket should you need to play along to a CD/MP3; FX loop sockets for your external
FX processors; and finally the LX120RTwin features a built in spring line reverb with master level control.
We hope you enjoy using your LX120RTwin as much as we enjoyed designing and making it.
Best wishes from all at Laney.
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
EXTREME/METAL
CLEAN
BLUES
ROCK LEAD
IN
IN
IN
OUT
QUICK START SETTINGS - Suggestions only experiment!

Laney
L10X 2RTWIN
66
Laney
L 1 0
X 2 RTWIN
77
EXTENSION LOUDSPEAKER
8 OHM MINIMUM IMPEDANCE
REFER TO USER MANUAL
FOR LOUDSPEAKER CONNECTIONS
www.laney.co.uk
Laney
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
POWER AMP IN
PRE AMP OUT
LX120RTWIN FRONT / REAR PANEL FEATURES
1
2
3
21
4
5
6
7
8
9
10
11
12
14
15
16
17
18
19
then be in complete control of the slave power amplifier.
Loudspeakers: Connect your louspeakers here. The impedance of the cabinet/s
should not be less than 4 Ohms. Connecting cabinets that have a lower inpedance
than 4 Ohms will result in the amplifier overheating. Continual use in this manner may
cause perminent damage.
Power Inlet Socket: Connect your power source here. Make sure that the
specified voltage is correct for your country! Also here in the drawer is the
main safety fuse for the unit. Only use the correct size and rating of fuse as
specified on the panel.
Main Power Switch: for the unit. (Always switch off and
disconnect the power cord when not in use)
Main Power LED: When illuminated indicates that power is
connected to the unit and it is ready to go.
FX Send / Return: Line level FX Loop to connect to an external
effects controller.
Footswitch: Connect a Laney FS2 footswitch here to enable
remote switching for the channel and reverb/FX. Note: Drive
channel must be enabled (via ) for channel switching with a
footswitch to function.
13
21
20
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
12
3
456
7
8
9
10
121314
15
16
17
18
19
20
11
13 Crunch ON/OFF: Switch in to activate the overdrive ‘Crunch’ channel. When active, control the amount of distortion with and the
overall volume with
Treble:Controls the amount of treble present on the clean channel.
Mid:Controls the amount of mid present on the clean channel.
Bass: Controls the amount of bass or bottom end present on the clean channel.
Volume: Controls the volume level of the clean channel.
Input: This socket should be used for connecting your instrument to the amplifier. Only use a good quality screened cable.
Power Amp In Preamp Out: These jacks are primarily used to connect other power amplifiers or to connect LX120RH amplifiers
together to boost power outputs. When connecting to another power amplifier the preamplifier output jack should be used. The signal at
this socket will be affected by all the controls on the preamplifier. When connecting two LX120RH amplifiers together to boost power
levels the master amplifier preamplifier out jack should be connected to the power amplifier input socket of the slave. The master will
12
11
CD/Line In:Fancy playing along with a backing track? Connect your CD/MP3 player here.
Reverb: Controls the amount of reverb applied to the signal
Treble: Controls the amount of treble present on the drive channel.
Mid: Controls the amount of mid present on the drive channel.
Bass: Controls the amount of bass or bottom end present on the drive channel.
XTS: eXtreme Tone Shaping. This applies a scooped mid tone shape to the drive channel and boosts certain key frequencies for a
unique sound.
Master: Controls the overall level on the drive channel. Use with
Crunch: Controls the crunch channel gain, low down for classic rock and blues, higher up for hard rock and metal.... the higher you
go the more Extreme it gets. Use in conjunction with to get the overall level balanced how you want it. LED Indicates that the
drive channel is active.
12
11

Laney
L10INX 2RTW
66
Laney
L 1 0X 2 RTWIN
77
EXTENSION LOUDSPEAKER
8 OHM MINIMUM IMPEDANCE
REFER TO USER MANUAL
FOR LOUDSPEAKER CONNECTIONS
www.laney.co.uk
Laney
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
POWER AMP IN
PRE AMP OUT
LX120RTWIN FRONT / REAR PANEL FEATURES
1
2
3
21
4
5
6
7
8
9
10
11
12
14
15
16
17
18
19
then be in complete control of the slave power amplifier.
Loudspeakers: Connect your louspeakers here. The impedance of the cabinet/s
should not be less than 4 Ohms. Connecting cabinets that have a lower inpedance
than 4 Ohms will result in the amplifier overheating. Continual use in this manner may
cause perminent damage.
Power Inlet Socket: Connect your power source here. Make sure that the
specified voltage is correct for your country! Also here in the drawer is the
main safety fuse for the unit. Only use the correct size and rating of fuse as
specified on the panel.
Main Power Switch: for the unit. (Always switch off and
disconnect the power cord when not in use)
Main Power LED: When illuminated indicates that power is
connected to the unit and it is ready to go.
FX Send / Return: Line level FX Loop to connect to an external
effects controller.
Footswitch: Connect a Laney FS2 footswitch here to enable
remote switching for the channel and reverb/FX. Note: Drive
channel must be enabled (via ) for channel switching with a
footswitch to function.
13
21
20
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
12
3
456
7
8
9
10
121314
15
16
17
18
19
20
11
13 Crunch ON/OFF: Switch in to activate the overdrive ‘Crunch’ channel. When active, control the amount of distortion with and the
overall volume with
Treble:Controls the amount of treble present on the clean channel.
Mid:Controls the amount of mid present on the clean channel.
Bass: Controls the amount of bass or bottom end present on the clean channel.
Volume: Controls the volume level of the clean channel.
Input: This socket should be used for connecting your instrument to the amplifier. Only use a good quality screened cable.
Power Amp In Preamp Out: These jacks are primarily used to connect other power amplifiers or to connect LX120RH amplifiers
together to boost power outputs. When connecting to another power amplifier the preamplifier output jack should be used. The signal at
this socket will be affected by all the controls on the preamplifier. When connecting two LX120RH amplifiers together to boost power
levels the master amplifier preamplifier out jack should be connected to the power amplifier input socket of the slave. The master will
12
11
CD/Line In:Fancy playing along with a backing track? Connect your CD/MP3 player here.
Reverb: Controls the amount of reverb applied to the signal
Treble: Controls the amount of treble present on the drive channel.
Mid: Controls the amount of mid present on the drive channel.
Bass: Controls the amount of bass or bottom end present on the drive channel.
XTS: eXtreme Tone Shaping. This applies a scooped mid tone shape to the drive channel and boosts certain key frequencies for a
unique sound.
Master: Controls the overall level on the drive channel. Use with
Crunch: Controls the crunch channel gain, low down for classic rock and blues, higher up for hard rock and metal.... the higher you
go the more Extreme it gets. Use in conjunction with to get the overall level balanced how you want it. LED Indicates that the
drive channel is active.
12
11

Laney
L10X 2RTWIN
88
Laney
L 1 0
X 2 RTWIN
99
General Notes
Amplifier connection: In order to avoid damage,
it is advisable to establish and follow a pattern for
turning on and off your equipment.
With all system parts connected, turn on source equipment, tape decks, cd players, mixers, effects processors etc. BEFORE turning on
your guitar amplifier.
Many products have large transient surges at turn on and off which can cause damage to your speakers. By turning on your guitar
amplifier LAST and making sure its Volume controls are set to minimum any transients from other equipment will not reach your
loudspeakers. Wait until all system parts have stabilised; usually a couple of seconds. Similarly when turning off your system always turn
down the Volume controls on your guitar amplifier and then turn off its power before turning off other equipment.
Servicing: The user should not attempt to service these products. Refer all servicing to qualified service personnel.
Caution: These professional loudspeaker
systems are capable of generating very high sound pressure levels.
Use care with placement and operation to avoid exposure to excessive levels that can
cause permanent hearing damage.
Cables: never use shielded or microphone cable for any speaker
connections as this will not be substantial enough to handle the
amplifier load and could cause damage to your amplifier system.
SAMPLE SETTINGS
FX Controller
Input Output
8 Ohms Link
Model RB115
Power Rating 300W Program
Model RB115
Power Rating 300W Program
Serial Number:Serial Number:
Input
Laney
Power To The Music
www.laney.co.uk
DESIGNED IN THE UK BY LANEY 8 Ohms Link
Model RB115
Power Rating 300W Program
Model RB115
Power Rating 300W Program
Serial Number:Serial Number:
Input
Laney
Power To The Music
www.laney.co.uk
DESIGNED IN THE UK BY LANEY
SAMPLE
LX412S

Laney
L10INX 2RTW
88
Laney
L 1 0X 2 RTWIN
99
General Notes
Amplifier connection: In order to avoid damage,
it is advisable to establish and follow a pattern for
turning on and off your equipment.
With all system parts connected, turn on source equipment, tape decks, cd players, mixers, effects processors etc. BEFORE turning on
your guitar amplifier.
Many products have large transient surges at turn on and off which can cause damage to your speakers. By turning on your guitar
amplifier LAST and making sure its Volume controls are set to minimum any transients from other equipment will not reach your
loudspeakers. Wait until all system parts have stabilised; usually a couple of seconds. Similarly when turning off your system always turn
down the Volume controls on your guitar amplifier and then turn off its power before turning off other equipment.
Servicing: The user should not attempt to service these products. Refer all servicing to qualified service personnel.
Caution: These professional loudspeaker
systems are capable of generating very high sound pressure levels.
Use care with placement and operation to avoid exposure to excessive levels that can
cause permanent hearing damage.
Cables: never use shielded or microphone cable for any speaker
connections as this will not be substantial enough to handle the
amplifier load and could cause damage to your amplifier system.
SAMPLE SETTINGS
FX Controller
Input Output
8 Ohms Link
Model RB115
Power Rating 300W Program
Model RB115
Power Rating 300W Program
Serial Number:Serial Number:
Input
Laney
Power To The Music
www.laney.co.uk
DESIGNED IN THE UK BY LANEY 8 Ohms Link
Model RB115
Power Rating 300W Program
Model RB115
Power Rating 300W Program
Serial Number:Serial Number:
Input
Laney
Power To The Music
www.laney.co.uk
DESIGNED IN THE UK BY LANEY
SAMPLE
LX412S

Laney
L10X 2RTWIN
1010
Laney
L 1 0
X 2 RTWIN
1111
INTERNAL
LOUDSPEAKERS
EXTERNAL
LOUDSPEAKER
BLOCK DIAGRAM & TECHNICAL SPECIFICATIONS
This product conforms to the requirements of the following European Regulations, Directives & Rules:-
CE Mark (93/68/EEC), Low Voltage (72/23/EEC), EMC (93/68/EEC),
RoHS (EU2002/95/EC), WEEE (EU2002/96/EC)
In order to reduce environmental damage, at the end of its useful life, this product must not be disposed of along with normal
household waste to landfill sites. It must be taken to an approved recycling centre according to the recommendations of the WEEE
(Waste Electrical and Electronic Equipment) directive applicable in your country.
INPUT
POWER
AMP
CD IN
DRIVE
CLEAN
XTS REVERB
FOOTSWITCH
EQ
SECTION
POWER
AMP IN
This loop is a series type
so all of your signal will go
through your FX unit.
PREAMP
OUT
FX
RETURN
FX
SEND
Supply Voltage: - Factory Preset
~100V, ~120V, ~220V, ~230V, ~240V 50/60Hz
Mains Fuse:
~220V>~240V = T1A L. ~100>~120V = T2A L
Power Consumption:
300 Watts
Output Power Rating:
120W
Input Impedance:
1MOhm/47pF
Size:
479*680*275 (H*W*D)
Loudspeakers:
2 Custom Designed Drivers
Features:
Rugged construction
TEC Tube Emulating Technology
XTS eXtreme Tone Shaping (Drive channel only)
Speaker socket (Minimum 8 Ohm Impedance)
CD In (10K Input impedance) (Nominal 750mV Input level)
FX Loop (Nominal 750mV Level)
Footswitchable:
Yes, Channel and FX (via FS2)
EQ:
Both channels contain separate Passive Bass, Middle and Treble
Unit Weight:
22.7 Kg (Shipping Weight: 24.2 Kg)
EQ
SECTION
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
USER SETTINGS - Store your own cool sounds!

Laney
L10INX 2RTW
1010
Laney
L 1 0X 2 RTWIN
1111
INTERNAL
LOUDSPEAKERS
EXTERNAL
LOUDSPEAKER
BLOCK DIAGRAM & TECHNICAL SPECIFICATIONS
This product conforms to the requirements of the following European Regulations, Directives & Rules:-
CE Mark (93/68/EEC), Low Voltage (72/23/EEC), EMC (93/68/EEC),
RoHS (EU2002/95/EC), WEEE (EU2002/96/EC)
In order to reduce environmental damage, at the end of its useful life, this product must not be disposed of along with normal
household waste to landfill sites. It must be taken to an approved recycling centre according to the recommendations of the WEEE
(Waste Electrical and Electronic Equipment) directive applicable in your country.
INPUT
POWER
AMP
CD IN
DRIVE
CLEAN
XTS REVERB
FOOTSWITCH
EQ
SECTION
POWER
AMP IN
This loop is a series type
so all of your signal will go
through your FX unit.
PREAMP
OUT
FX
RETURN
FX
SEND
Supply Voltage: - Factory Preset
~100V, ~120V, ~220V, ~230V, ~240V 50/60Hz
Mains Fuse:
~220V>~240V = T1A L. ~100>~120V = T2A L
Power Consumption:
300 Watts
Output Power Rating:
120W
Input Impedance:
1MOhm/47pF
Size:
479*680*275 (H*W*D)
Loudspeakers:
2 Custom Designed Drivers
Features:
Rugged construction
TEC Tube Emulating Technology
XTS eXtreme Tone Shaping (Drive channel only)
Speaker socket (Minimum 8 Ohm Impedance)
CD In (10K Input impedance) (Nominal 750mV Input level)
FX Loop (Nominal 750mV Level)
Footswitchable:
Yes, Channel and FX (via FS2)
EQ:
Both channels contain separate Passive Bass, Middle and Treble
Unit Weight:
22.7 Kg (Shipping Weight: 24.2 Kg)
EQ
SECTION
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
CD/LINE INFOOTSWITCH
LX120RTWIN
REVERB FX SEND FX RETURNTREBLEMIDBASSMASTERCRUNCHTREBLEMIDBASSVOLUME XTS
DRIVE EQUALISATIONDRIVECLEAN
POWER
1
0
ON
INPUT
USER SETTINGS - Store your own cool sounds!

In the interest of continued product development, Laney reserves the right to amend product specification without prior notification.
POWER TO THE MUSIC
Laney
LA N E Y A M P L I F I C A T I O N
w w w. l a n ey. c o. u k
Other Laney Musical Instrument Amplifier manuals

Laney
Laney LX 10 User manual

Laney
Laney Black Country Customs Supermod LA100SM User manual

Laney
Laney Alliance VH100R User manual

Laney
Laney LX 10 User manual

Laney
Laney TT50H User manual

Laney
Laney Richter Bass RB2 User manual

Laney
Laney PB 150 HEAD User manual

Laney
Laney LX15B User manual

Laney
Laney LA30C User manual

Laney
Laney GH50L User manual

Laney
Laney MINISTACK Series User manual

Laney
Laney Richter R1 User manual

Laney
Laney Iron heart User manual

Laney
Laney GS412PA User manual

Laney
Laney TI412S User manual

Laney
Laney IronHeart IRT60H User manual

Laney
Laney Richter Bass RB7 User manual

Laney
Laney LV100 User manual

Laney
Laney Prism P20 User manual

Laney
Laney AudioHub AH40 User manual