LPF30F_UG_ENB01W
www.lanpro.com
User Guide for SC Field Installable
LP-F30F Connectors (2.0/3.0 mm type)
Step 1: Insert the boot
and ring into the cable.
Step 3: Strip off the
jacket from the MARK 3.
Step 5: Strip off the
buffer and 250um
coating till MARK 1,
and keep 125um ber.
Step 7: Press the LP-F30F tool and then insert the
125um ber to reach the innermost until the buffer
make a curve. Then release the tool and check if this
buffer is tight.
Step 9: Release the
tape to take out the
LP-F30F connector,
and cut the extra yarn.
Step 11: Release the
tape to take out the
LP-F30F connector,
and done.
Step 2: Make a mark
on cable according to
MARK 3 of the length
chart.
Step 4: Make marks
on buffer according to
the length chart
(MARK 1: The starting
point to strip the buffer.
MARK 2: Check point).
Step 6: Follow the
LP-F30FTOOL FIBER
CUTTER MANUAL
to cut the ber
Step 8: Place the yarn in the slot of both side, then
screw the ring.
Step 10: Move the
boot toward to the
stopper.
MARK 3
MARK 2 MARK 1