manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. lapara
  6. •
  7. Surge Protector
  8. •
  9. lapara LA-SP7 User manual

lapara LA-SP7 User manual

Popular Surge Protector manuals by other brands

Philips Theatre Director SPP4200WA/17 Owner's manual & warranty

Philips

Philips Theatre Director SPP4200WA/17 Owner's manual & warranty

M-system MMA instruction manual

M-system

M-system MMA instruction manual

CyberPower CSP600WSU user manual

CyberPower

CyberPower CSP600WSU user manual

UTP BALUN SP-VD08 user manual

UTP BALUN

UTP BALUN SP-VD08 user manual

ELAC ProteK PR91-W Setup guide

ELAC

ELAC ProteK PR91-W Setup guide

Tsubaki TSM4000M1 instruction manual

Tsubaki

Tsubaki TSM4000M1 instruction manual

CyberPower B1006T user manual

CyberPower

CyberPower B1006T user manual

QVS PP134C Specification sheet

QVS

QVS PP134C Specification sheet

Davis Instruments Radio Surge Protector user guide

Davis Instruments

Davis Instruments Radio Surge Protector user guide

CyberPower B300WRC1 user manual

CyberPower

CyberPower B300WRC1 user manual

M-system MGD-24 instruction manual

M-system

M-system MGD-24 instruction manual

Panamax MAX 5400-EX owner's guide

Panamax

Panamax MAX 5400-EX owner's guide

OBO Bettermann ÜSM-20-230I1PE65 installation instructions

OBO Bettermann

OBO Bettermann ÜSM-20-230I1PE65 installation instructions

CyberPower CSP604T user manual

CyberPower

CyberPower CSP604T user manual

CyberPower CSP706T user manual

CyberPower

CyberPower CSP706T user manual

Mitsubishi Electric LITOL LTM-125RF manual

Mitsubishi Electric

Mitsubishi Electric LITOL LTM-125RF manual

Intermatic PS3000 installation instructions

Intermatic

Intermatic PS3000 installation instructions

Siemens SICROWBAR 7VV3003 operating instructions

Siemens

Siemens SICROWBAR 7VV3003 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Quick Guide
___________________________________________________ __________________________________________________
LA-SP7 (V.1.12011) LA-SP7 (V.1.1 2011)
LA-SP7
Surge Protector
1. Introduction
Thank you for purchasing Lapara product. This item is designed to provide surge protection
and power extender for connected devices. With its master-controlled design, the unit
provides energy saving by shutting down unused peripherals. The master outlet is designed to
sense current drawn by connected equipment, usually a computer. When the computer is
shut down, it will shut off power to slave outlets which connect all PC peripherals.
2. Product Overview 
Master output receptacle (for connecting a
computer)

Uncontrolled output receptacles (for
connecting peripherals)

Slave output receptacles (for connecting
peripherals)

Modem/phone line surge protection

Function switch

Circuit breaker

AC input

Power LED

Master/Slave Function LED
Wall Mount the Unit
The unit can be mounted to a wall surface. Please follow below steps:
1. Use tape to hold this page in place against the wall.
2. Use a sharp nail to puncture the center of the two holes to mark the wall. (see below chart 1)
3. Mount the unit by positioning the key-hole slots over the mounting nails. (see chart 2)
3. Installation and Operation
Inspection
Remove the unit from the shipping package and inspect it for damage that may occurred
during transportation. Notify the carrier and place of purchase if any damage is found.
___________________________________________________ __________________________________________________
LA-SP7 (V.1.12011) LA-SP7 (V.1.1 2011)
Connect to the Wall Outlet
Plug the input power cord of the unit to the wall outlet. The Power LED will light up when the
mains is normal. The Power LED will be off while power failure.
Connect Equipment
There are three types of output receptacles: Master, Slave, and Uncontrolled.
Master/Slave Output Receptacles
To save power consumption, the unit is equipped with Master and Slave output receptacles.
The Master output receptacle will sense if master device (computer) is on. If the master
device is no longer drawing current, it will automatically shut down the power to the Slave
output receptacles. Please refer to below charts for detailed equipment connection.
Note: Do not connect devices to the slave output receptacles if you want them to continue
running when your computer is off.
NOTE: When the computer is turned off, the Master output receptacle shuts off power to the
slave output receptacles. However, when the computer goes into “sleep mode” or the power
consumption of connected device to Master output receptacle is below 20 W, the Master
output receptacle may not properly recognize the reduced power level.
Uncontrolled Output Receptacles
Equipment connected to uncontrolled output receptacles will continue running when the unit
is powered on and utility is normal even though Master device is shut down.
After connecting all devices to the unit, press “Function switch” to enable master/slave
function. The Function LED will light up. Press “Function switch” to disable the function and
the Function LED will be off.
Status Indicator
Utility is normal Power LED (Green) on
Utility fails Power LED (Green) off
Master/Slave function is enabled Master/Slave Function LED (Yellow) on
Master/Slave function is disabled Master/Slave Function LED (Yellow) off
Connect Modem/Phone for Surge Protection
Connect a single modem/phone line into surge-protected “IN” outlet on the unit. Connect
from “OUT” outlet to the computer with phone line cable.
Placement & Storage Conditions
Install the unit in a protected area that is free of excessive dust and has adequate air flow.
Please place the unit away from other units at least 2.5cm to avoid interference. Do NOT block
the top or side air vents on the unit.
Plug Computer into Plug Peripherals into
Master Output Receptacles Slave Output Receptacles
Do not operation the unit in an environment where the ambient temperature or humidity is
outside the limits listed in the specifications. Operate the unit in an environment free of
excessive dust, mechanical vibration, inflammable gases and explosive or corrosive
atmospheres.
Monitor Scanner
4. Important Safety Warning (SAVE THESE INSTRUCTIONS)
Computer To safely operate this voltage regulator, please read and follow all instructions
carefully. Read this manual thoroughly before attempting to unpack, install, or
operate. You may keep this quick guide for further reference.
Printer Hub
CAUTION: The unit is designed only for use under the 50 Hz input frequency and pure sine
wave environment. Any other input frequency or wave form will effect the voltage range
and load capability.
CAUTION: Please DO NOT connect the unit to the environment with direct voltage or
simulated sine wave.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and
humidity controlled indoor area free of conductive contaminants. (See the specifications for
the acceptable temperature and humidity range.)