Page 2 of 3 75.5316.00 20080111
4 Installation
5 Company Contact
1Mounting the Pushplate
The Wireless Pushplate may be mounted WITH or WITHOUT
the mounting plate. To use the mounting plate, screw a
minimum of two (2) screws into a solid surface through the
holes in the mounting plate (#8 countersunk head screws must
be used). The mounting plate must be mounted so that the
text side is facing up.
To attach the housing to the mounting plate, place the housing over the key
tabs on the mounting plate and then slide the plate downward until the locking
tab engages the housing. To remove the housing, press in the locking tab and
reverse this procedure.
NOTE: To securely lock the plate, put an additional screw through both
the housing and the mounting plate.
LOCKING TAB
2Pushplate Function
To assemble or disassemble the pushplate, use the enclosed
hex key (or similar diameter tool) to press in and release the
spring clips from the housing. The spring clip will need to be
engages / disengages from the top and bottom, one at a time.
When the spring clips are correctly engaged, they will make a
CLICK. It may be necessary to rotate the faceplate slightly to
have them lock correctly.
To replace the battery, remove the faceplate and the four (4) screws holding
the battery cover to expose the transmitter assembly. Replace the battery with
a fresh 12V (A23) battery and reassemble the pushplate.
WARNING: DO NOT OVER TIGHTEN THE SCREWS ON THE BATTERY
COVER. THIS MAY CAUSE THE TRANSMITTER TO BE IN
CONSTANT ACTIVATION. THE HEAD OF THE SCREWS
SHOULD BE FLUSH WITH THE TOP OF THE PLASTIC COVER.
MOUNTING KEYS
DOUBLE GANG
MOUNTING HOLES (4)
ENGAGE KEYS
LOCK / UNLOCK
BATTERY LOCATION
(OBSERVE PROPER POLARITY)
DETACH / REATTACH
(LISTEN FOR CLICK)
PRESS
(TOPAND THEN
BOTTOM)
3Receiver Setup
For complete Receiver (8310-865, sold separately) Setup & Installation procedures, refer to LCN publication 75.5315 (433MHz Trans-
mitters & Receiver User’s Guide).
Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem,
please contact LCN at 1-800-526-2400. If you must wait for the following workday to call LCN, leave the door
inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or gate
for an incomplete solution.
For more information, visit www.lcn.ingersollrand.com.