MPS-8Z connection to an audio system with ZES-22
1 HOW IT WORKS
This support manual explains how to correctly connect the LDA MPS-8Z S02
microphone to the LDAZES-22 S02 digital audio matrix via the LDAZES-22ACSI S01
adapter.
1.1 Power supply
The MPS 8Z is supplied with an external power supply with a 5V female USB type A
connector, which is connected via a mini-USB AB male to USB A male cable, also
supplied. You can either use it to power the device, or power the device directly from the
ACSI bus, via its bus connection. If this is the case, save the power supply for later use.
1.1.1 Power Source Selector
The equipment has a "PWR" selector shown in Picture 1: MPS-8Z power switch detail
detail that allows choosing the source of the power supply between local, or supplied
through the ACSI bus.
When the selector is in the OFF position, the equipment will be powered locally, by the
external charger (supplied with the equipment). When the selector is in the ON position,
the MPS-8Z will be powered from the ACSI bus. In this case, if the local charger is also
connected, it will automatically switch to the local charger if the power supply from the
ACSI bus is interrupted.
1.2 RS-485 connection
To properly make the connection between the MPS-8Z microphone and the ZES-22
matrix, a specific configuration of a UTP cable must be available; using a is category 5 or
higher cable.
Starting from the connection diagram of an RJ-45 terminal (see Picture 2: Colour chart
for RJ45 type B connections), the connection in Table 1: Pinout of the RJ45 connector.