LDPI LEHL1 Manual

Terminal
Block LED Driver
(-)
(+)
(LEAD WIRES
TO LED LOAD)
WHITE (NEUTRAL)
GREEN (GROUND)
BLACK (LINE)
AC INPUT
General Wiring Diagram
Installation and Operation
Product Size
Pendant Type
CAUTION: Turn off electrical power at
fuse or circuit breaker box before
wiring fixture to the power supply.
Connecting panels to the AC source
supply:
All units must be individually connect-
ed to the AC supply.
Black = Line
White = Neutral
Green = Ground
Electrical Connection:
1. Loosen the three M5 socket head cap screws with spring washers on the driver housing Cover.
2. The entry hole of the driver housing is 3/4” NPT. Attach to suitable conduit.
3. Run the wire from outside through the conduit and the entry hole of driver housing, and then connect it to
the Terminal Block.
4. Re-attach the housing cover and tighten it with the three M5 socket head cap screws and spring washers
at torque value 5 N-m.
1. Attach the driver housing to the threaded 3/4" pipe and tighten with M4 fastening screws.
2. Connect the electrical part.
3. Re-attach the fixture to the driver housing and tighten it with the three M5 socket head cap screws and
spring washers.
Φ262mm /10.3in
155mm / 6.1in
step1
step2
step3
Set screw
M4
Socket head cap screws
M5
U-Bracket
1. Use the four M8 expansion bolts to attach the bracket to the wall.
2. Connect electrical part.
3. Re-attach the fixture to the driver housing and tighten it with the three M5 socket head cap screws and
spring washers. Adjust the angle of the fixture with the M4 screws.
Ceiling Mount
Stanchion 25°/90°
1. Use the four M8 expansion bolts to attach the bracket to the ceiling.
2. Use the six M4 hexagon socket screws to attach the driver housing to the bracket.
3. Fixture should be hung on the driver housing; connect the wires.
4. Re-attach the fixture and tighten it with the three M5 socket head cap screws and spring washers.
1. Screw the bracket to the pole then tighten the M5 fastening screws.
2. Use six M4 hexagon socket screws to attach the driver housing to the bracket.
3. Connect the electrical part.
4. Re-attach the fixture to the driver housing and tighten it with the three M5 socket head cap screws and
spring washers.
step1
step2
Socket head cap screws
M5
Screws
M4
(Gasket+Washers induded) M8
Expansion bolts
step3
(Gasket+Washers induded) M8
Expansion bolts
step1
step2
M4 Socket head cap screws
M4
step3
step4
M5
Socket head cap screws
step1 step2
step3 step4
M4
Socket head cap screws
Screws
M5
M5
Socket head cap screws
D-1319 v.07.16.19
Page: 3
D-1319 v.07.16.19
Page: 2
LDPI, Inc. / (800) 854-0021 / www.ldpi-inc.com / [email protected] LDPI, Inc. / (800) 854-0021 / www.ldpi-inc.com / [email protected]
Φ262mm /10.3in
279mm /
11in
Operational Data
Housing
INSTALLATION, OPERATION AND
MAINTENANCE INSTRUCTIONS
LEHL1 LED HAZARDOUS LOCATION
LIGHTING FIXTURES
1. Operate this fixture at its rated voltage. Do not install where the marked operating temperature exceeds
the ignition temperature of the hazardous atmospheres. See fixture label for data.
2. This fixture is intended to be connected to a properly installed and grounded UL listed junction box.
Heavy-duty anodized die cast aluminum
Long lasting and durable powder coat finish
Over-voltage, and over-heat protection
Exposed fasteners with quality stainless steel
Excellent anti-corrosive property
WARNING!
1. TO PREVENT THE RISK OF ELECTRICAL SHOCK DEACTIVATE/DISCONNECT
THE POWER SUPPLY BEFORE INSTALLING THE FIXTURE.
2. THE DRIVER IN THIS FIXTURE IS DESIGNED TO OPERATE ON GROUNDED
NEUTRAL SYSTEMS ONLY.
3. THIS FIXTURE SHOULD BE INSTALLED BY QUALIFIED TECHNICIANS IN STRICT
ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ANY LOCAL
REQUIREMENTS.
Wall 25°/90°
1. Use the four M8 expansion bolts to attach the bracket to the wall.
2. Use the six M4 hexagon socket screws to attach the driver housing to the bracket.
3. Fixture should be hung on the driver housing; connect the wires.
4. Re-attach the fixture and tighten it with the three M5 socket head cap screws and spring washers.
Servicing
To avoid personal injury, disconnect power to the fixture and allow it to cool down before performing mainte-
nance.
Perform visual, electrical, and mechanical inspections on a regular basis. The environment and frequency of
use should determine this. However, it is recommended that checks should be made at least once a year.
The external glass should be cleaned periodically to ensure continued performance. Clean the glass with a
clean, damp, non-abrasive, lint-free cloth. If this is not sufficient, use a mild soap or a liquid cleaner. Do not
use an abrasive, strong alkaline, or acid cleaner as damage may occur.
Inspect the cooling fins on the fixture to ensure that they are free of any contamination (i.e. excessive dust
build-up). Clean with a non-abrasive cloth if needed. Mechanically check to make sure all parts are properly
assembled.
Electrically check to make sure that all connections are clean and tight.
step1 step2 step3
step5step4
M4
Socket head cap screws
(Gasket+Washers induded) M8
Expansion bolts
D-1319 v.07.16.19
Page: 4
LDPI, Inc. / (800) 854-0021 / www.ldpi-inc.com / [email protected] D-1319 v.07.16.19
Page: 1
LDPI, Inc. / (800) 854-0021 / www.ldpi-inc.com / [email protected]

Popular Lighting Equipment manuals by other brands

Vision & Control LDLF30x180-B470/24V/-a Instructions for use

Vision & Control

Vision & Control LDLF30x180-B470/24V/-a Instructions for use

Ibiza LMH350RGBW user manual

Ibiza

Ibiza LMH350RGBW user manual

Goobay 49873 user manual

Goobay

Goobay 49873 user manual

Clas Ohlson WX-P-31VLED44-150WW-1 quick start guide

Clas Ohlson

Clas Ohlson WX-P-31VLED44-150WW-1 quick start guide

Brightz tossbrightz instructions

Brightz

Brightz tossbrightz instructions

Lightolier Alter Waves QVL2GPFSS432 specification

Lightolier

Lightolier Alter Waves QVL2GPFSS432 specification

LIVARNO home 970-K manual

LIVARNO home

LIVARNO home 970-K manual

Smith-Victor PRO Series quick start guide

Smith-Victor

Smith-Victor PRO Series quick start guide

Lightolier 4190 Instructions for installation

Lightolier

Lightolier 4190 Instructions for installation

Portfolio 19530-000 installation instructions

Portfolio

Portfolio 19530-000 installation instructions

thomann VARYTEC LED Theater Spot 50 3200K user manual

thomann

thomann VARYTEC LED Theater Spot 50 3200K user manual

FOSCARINI Dolmen terra manual

FOSCARINI

FOSCARINI Dolmen terra manual

Lithonia Lighting ELU 4 installation instructions

Lithonia Lighting

Lithonia Lighting ELU 4 installation instructions

Home Accents Holiday TY449-1611-1 Use and care guide

Home Accents Holiday

Home Accents Holiday TY449-1611-1 Use and care guide

Lena Lighting UP LED Installation instruction

Lena Lighting

Lena Lighting UP LED Installation instruction

Abriblue OPEN Classic installation instructions

Abriblue

Abriblue OPEN Classic installation instructions

Draper Slimline 65421 manual

Draper

Draper Slimline 65421 manual

Prolux LED PAR 1818 user manual

Prolux

Prolux LED PAR 1818 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.