USER MANUAL
LL ARC MINI LINE WHITE
Leader Light s.r.o.
M.Gorkeho 33
SK-052 01 Spisska Nova Ves
Slovakia
www.leaderlight.eu
LL40 205
ENVIRONMENT
Do not throw away the appliance with the normal household waste at the end of its life,
but hand it in at an ofcial collection point for recycling. By doing this, you help to preserve
the environment.
WARNING!!!
Carefully read before installing, powering or servicing.
Nothing to do if anything misunderstand! Installation can be done only
by a qualied professional in accordance with relevant local codes.
01 SAFETY INFORMATION
01.1 Risk of eyes damage
Do not look directly into LED lamps.
Do not look into light beam from a distance of less than 40 cm (16 inches)!
-
-
01.2 Protection from electric shock
Shut down power before installation or maintenance.
Luminaries, Driver and recommended power supply must be installed by a qualied
professional in accordance with relevant local codes. Only acceptable source of power and
frequency that complies with local building and electrical codes to use.
Do not use or do not connect the products if the power cable, power plug or xtures are any
way damaged, wet, or if they are overheating.
Do not modify, alter, or attempt to service the LeaderLight appliance. Doing so will void the
warranty.
Before removing or installing any cover or part of appliance disconnect from power.
-
-
-
-
-
01.3 Fire prevention
Follow all safety consideration.
Thermostatic switches or fuses never to bypass.
Device never shield – minimum distance around tting must be 50mm (2 in.).
LEDs never direct cover with lters or other materials.
Allowing max. ambient temperature is 40°C (104°F).
-
-
-
-
-
02 PRODUCT SPECIFICATION
02.1 Technical Specication
03 INSTALLATION
03.1 Unpacking
Unpack carefully.
This is electronic equipment and should be handled carefully.
Damaged delivered package or if are any mechanical parts broken – it must be claim
immediately by the transport company. Photo pictures as evidence are valuable or
future claim.
-
-
-
03.2 Physical installation
Loading capacity of bearing area has to be at least 10 times the weight of all device
clusters (luminaries, clamps, cables, ...).
Hairbreadth from combustible materials is 0,5m.
-
-
©MMX - Leader Light – All right reserved If you have any question please, contact [email protected]
COMPLIMENTS ON YOUR PURCHASE!
LL40 215 LL40 225
Content:
01 SAFETY INFORMATION
01.1 Risk of eyes damage
01.2 Protection from electric shock
01.3 Fire prevention
02 PRODUCT SPECIFICATION
02.1 Technical Specication
03 INSTALLATION
03.1 Unpacking
03.2 Physical installation
03.3 Electrical installation
03.3.1 Connecting to AC/DC power supply
03.3.2 Connecting to LL ARC DRIVER for intensity/colour control
04 MAINTENANCE
03.3.1 Connecting to DC power supply (Figure Nr. 1.1)
LL ARC MINI LINE must be connected to the device- MW power supply
IN:100-260AC/ OUT: 24V.
It is not necessary to open xture before connecting to MW power supply.
AC Power Supply Cord plug connections to MW Power supply:
-
-
Symbol Pin Wire Colour Screw (US)
Llive brown yellow or brass
Nneutral blue silver
ground (earth) yellow/green green
03.3.2 Connecting to LL LED DRIVER (Figure Nr. 1.2)
For intensity and colour control is necessary connection with LL ARC DRIVER.
It is not necessary to open xture before connecting to LL ARC DRIVER.
Before installing of LL ARC DRIVER carefully read USER MANUAL for LL ARC DRIVER.
-
-
-
03.3 Electrical installation
To tackle all Safety Information- 01!
You can suffer a dangerous electric shock by using a high voltage AC/DC
power supply - by touching the AC/DC power supply wires inside LL ARC MINI LINE!
LL ARC MINI LINE can be operated in two ways:
- 03.3.1 LL ARC MINI LINE connecting to DC POWER SUPPLY - for switch ON/OFF
luminaries
- 03.3.2 LL ARC MINI LINE connecting to LL ARC DRIVER - for intensity and colour
control
-
-
-
Edition: A - 2010
All dimensions are in milimeters
Φ38
Lamp type: 1200mm: 96xW TOP LED (White)
600mm: 48xW TOP LED (White)
300mm: 24xW TOP LED (White)
Lifetime: Long 100 000 hrs 60% degradation
View Angle: 120°
Control data Input: 1 channel 24V dimming
Power input: 1200mm: max. 8W
600mm: max. 4W
300mm: max. 2W
Power connection: 24V DC 5m cable with 6pin LINE connector
Net weight: 1200/600/300mm: 1kg/ 0,6kg/ 0,3kg
Dimensions LxΦ:
1200/600/300mm x 38mm without bracket
IP: IP20
Ambient temp. (Ta): Maximum 40°C
Cooling: Conventional
Materials and nish: End cups: plastic
Cover: frosted PMMA
Installation: Any position for ceiling, wall and surface-mounting
300
600
1200
Operation only with DC 24V source! By using a high voltage AC power supply-danger
of electric shock!
Following items are included:
- LL ARC MINI LINE with 5m cable and 6pin LINE connector 1 pc.
- LL BRACKET MINI LINE FIX 1 pc.
- User manual 1 pc.
Additional items needed:
- LL ARC DRIVER
- DC power supply 24V
- Controller compatible with DMX
- Mounting accessories (adjustable bracket)
- Screws and washers M6
If you have any question please, contact [email protected]
Order code Product name IC (A)
LL40 205 LL ARC MINI LINE White 300 1x0,08A
LL40 215 LL ARC MINI LINE White 600 3x0,16A
LL40 225 LL ARC MINI LINE White 1200 3x0,32A
Accessories:
LL41 170 LL BRACKET ARC MINI LINE 300 ADJUSTABLE
LL41 171 LL BRACKET ARC MINI LINE 600/1200 ADJUSTABLE
LL41 150 LL BRACKET ARC MINI LINE FIX
1.1
DC 24V
max. 10A
DIN
POWER
SUPPLY
MW 240
DIN 24V
100-260V AC
LL ARC MINI LINE connecting to DIN POWER SUPPLY enables to switch ON/OFF luminaries.
04 MAINTENANCE
To tackle all Safety Information- 01!
Damage caused by inadequate cleaning or maintenance is not covered by warranty.
Regular cleaning is demand (dust, dirt, ...).
Maintenance policy:
Unplug mains before maintenance and at least 10 minutes cool off
Appliance do not illegal open or demount
Clean-up dust only from outer surface (for ex. diffuser).
Use vacuum or dumpy duster (warm water)
Before reinstalling to check failure-free state – no wet parts!
-
-
-
-
-
-
-
-
1.2
LL ARC MINI LINE connecting to PWM DRIVER and DIN POWER SUPPLY enables to switch ON/OFF luminaries and in addition intensity and colour control by DMX controller.
max. 16A
max. 10A!
DC 24V
100-260V AC
DIN POWER
SUPPLY
MW 240
DIN 24V
DMX
CONTR.
connect max. 1,4A per GROUP
MINI LINE W
MINI LINE W
MINI LINE W
R+ R- G+ G- B+ B-
black
white
White
End cup
- standard delivery with luminary
FIX BRACKET
- standard delivery with luminary
180°
AIMING POSSIBILITY
The xture could be aim to wish
position with adjustable bracket.
MOUNTING ACCESSORIES
Adjustable bracket

This manual suits for next models

6

Other Leader Light Light Fixture manuals

Leader Light LL36 104 User manual

Leader Light

Leader Light LL36 104 User manual

Leader Light LL36 104 User manual

Leader Light

Leader Light LL36 104 User manual

Leader Light LL LED FLOOD NEO Z-POWER RGBAW User manual

Leader Light

Leader Light LL LED FLOOD NEO Z-POWER RGBAW User manual

Popular Light Fixture manuals by other brands

Whelen Engineering Company Delta Independence installation guide

Whelen Engineering Company

Whelen Engineering Company Delta Independence installation guide

Lightolier LL4MF8LR232 specification

Lightolier

Lightolier LL4MF8LR232 specification

American DJ Fantasy Scan 250 User instructions

American DJ

American DJ Fantasy Scan 250 User instructions

Philips 69101-30-PH Specification sheet

Philips

Philips 69101-30-PH Specification sheet

Lightolier QVS2GPTOS232 specification

Lightolier

Lightolier QVS2GPTOS232 specification

Paradise Datacom GL38682 quick start guide

Paradise Datacom

Paradise Datacom GL38682 quick start guide

Philips ProSpec 37108 specification

Philips

Philips ProSpec 37108 specification

Velvet SWORD Series user manual

Velvet

Velvet SWORD Series user manual

Robe ColorWash 575 AT ZOOM Service manual

Robe

Robe ColorWash 575 AT ZOOM Service manual

Stagg BAT XS user manual

Stagg

Stagg BAT XS user manual

Boost BOOST-LIGHT70 instruction manual

Boost

Boost BOOST-LIGHT70 instruction manual

Beamz 151.350 user manual

Beamz

Beamz 151.350 user manual

Osram KREIOS FLx Installation and safety instructions

Osram

Osram KREIOS FLx Installation and safety instructions

Chauvet LEG-5000 supplementary guide

Chauvet

Chauvet LEG-5000 supplementary guide

GLP KNV Cube user manual

GLP

GLP KNV Cube user manual

UltraPro ESCAPE LED Rope Light user manual

UltraPro

UltraPro ESCAPE LED Rope Light user manual

Philips selecon plcyc1 MKII Installation & user manual

Philips

Philips selecon plcyc1 MKII Installation & user manual

Philips Vari-lite VL3500 Wash FX Luminaries user manual

Philips

Philips Vari-lite VL3500 Wash FX Luminaries user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.