manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Leader Light
  6. •
  7. Light Fixture
  8. •
  9. Leader Light LL36 104 User manual

Leader Light LL36 104 User manual

©MMXI - LEADER LIGHT – All right reserved Edition: A - 2011 Additional information on [email protected]
LEADER LIGHT s.r.o.
M.Gorkeho 33
052 01 Spisska Nova Ves
Slovakia
www.leaderlight.eu
USER MANUAL
Page 1 /2
ENVIRONMENTAL PROTECTION
Do not throw away the appliance with the normal household waste at the end of its
life, but hand it in at an ofcial collection point for recycling. By doing this, you help to
preserve the environment.
COMPLIMENTS ON YOUR PURCHASE!
All dimensions are in millimeters
Package includes:
Content:
01 SAFETY INFORMATION
01.1 Risk of eyes damage
01.2 Safety instructions
01.3 Fire protection
02 PRODUCT SPECIFICATION
02.1 Technical specication
02.2 Product description
03 INSTALLATION
03.1 Unpacking
03.2 Physical installation
03.3 Connection
03.4 Control data connection
03.5 DMX channels
04 PERMANENET USE LIMITATIONS
05 MAINTENANCE AND SERVICE
!
LL STAGE WASH
LL36 104 LL36 106 LL36 108
LL76 105 LL76 107 LL76 109
02.2 Product description
Indication of control LEDs (LED power- green,LED data - yellow)
LED Indication Status
LED Power blinking - 2Hz O.K. - Device is working correct
LED Data not lit No DMX signal
LED Data blinking - 4Hz O.K. - Correct DMX signal
LED Data fast blinking ERROR - Incorrect digital signal
LED Power &
LED Data alternating blinking function AutoTest
03 INSTALLATION
03.1 Unpacking
Unpack carefully.
This is electronic equipment and should be handled carefully.
Damaged delivered package or if are any mechanical parts broken – it must be
claim immediately by the transport company. Photo pictures as evidence are
valuable for future claim.
-
-
-
03.2 Physical installation
Loading capacity of bearing area has to be at least 10 times the weight of all
device clusters.
Hairbreadth from combustible materials is 0,5m.
Before physical installation insert the optic modul on front of luminary. The optic
installation is easy and fast by 2 screws. (gures Nr. 3.1 to 3.2)
-
-
-
03.3 Connection
Respect all SAFETY INFORMATION 01!
Connect the ground (earth) !
It is not necessary to open the xture before power supply. Power supply is
solved simple with Neutrik PowerCon connectors.
The xture is equipped with auto-switching power supply that automatically
adjusts to any 50-60Hz AC power source from 100-260V.
Cord plug connections:
-
-
-
-
-Symbol Pin Wire Colour Screw (US)
Llive brown yellow or brass
Nneutral blue silver
ground (earth) yellow/green green
!
600
125
120
1. Version without Vario optic 2. Version with Vario optic
LL STAGE WASH with adj. bracket
- 1pc.
LL STAGE WASH with adj. bracket
- 1pc.
PowerCon type “A“ + “B“- 1pc.
LL VARIO OPTIC WASH 600 15°
- 1pc.
User manual- 1pc. PowerCon type “A“ + “B“- 1pc.
User manual- 1pc.
Additional items needed:
Data cables with XLR 5pin F/M- 1pc.
Controller compatible with DMX- 1pc.
Mounting accessories as necessary-
!!
Dip options
Rotating DIP address 000÷511
“100“ “10“ “1“
DMX Out
XLR-5pin
DMX In
XLR-5pin
Power In
PowerCon
Power Out
PowerCon
Control LEDs
LL S TA GE WA SH
Made in EU
Leader Light s.r.o.
Slovakia 2009
www.leaderlight.eu
[email protected]
MODE ADDRESS
POWER DATA
WARNING - Disconnect
mains before remove cover!
! !
WARNING!!!
Non-minimum distance and / or non-use the
original brackets is at your own risk!
01 SAFETY INFORMATION
WARNING!!!
Carefully read before installing, powering or servicing. Nothing to do if
anything misunderstand! Installation can be done only by a qualied
professional in accordance with relevant local codes.
01.1 Risk of eyes damage
Do not look directly into LED lamps.
Do not look into light beam from a distance of less than 40 cm (16 inches)!
-
-
WARNING!!! AWUV versions:
Overall allowable time of exposure of unprotected eyes in relation to
the distance from the light source results:
distance (m) 0,6m 1,0m 2,0m 3,0m
max. exposure time (h:m:s) 0:17:52 0:35:55 1:35:24 2:43:08
01.2 Safety instructions
Shut down power before installation or maintenance.
Do not modify, alter, or attempt to service the LEADER LIGHT appliance. Doing
so will void the warranty.
Appliance and recommended AC power supply must be installed by a qualied
professional in accordance with relevant local codes. Use only acceptable source
of AC power and frequency that complies with local biulding and electrical codes.
Use only the recommended voltage source.
Appliance always connect to earth (eltech.)!
Do not use or do not connect the products if the power cable, power plug or
xtures are any way damaged, wet, or if they are overheating.
Before removing or installing any cover or part of appliance disconnect it from AC
power.
AC power supply must be protected against overvoltage and short circuits.
-
-
-
-
-
-
-
-
01.3 Fire protection
Follow all safety restrictions.
Thermostatic switches or fuses never to bypass.
Device never shield. Around the axis of the tting (180°) must be maintained space
for cooling.
Minimum distance from the surrounding objects must be 100mm (4 in.).
LEDs never direct cover with lters or other materials.
Allowing max. ambient temperature is 40°C (104°F).
Luminaries never use without mounting brackets. The housing never install
directly to the surface.
-
-
-
-
-
-
02 PRODUCT SPECIFICATION
02.1 Technical specication
Power connection: 100-260V AC 50-60Hz In/Out PowerCon
IP: IP20
Control data: DMX 512 In/Out with XLR 5pin
Ambient temp. (Ta): Maximum 40°C
Net weight: 6kg
Installation: Surface mounting
©MMXI - LEADER LIGHT – All right reserved Edition: A - 2011 Additional information on [email protected]
Page 2 /2
Camloc 1/4 turn fasteners
Safe mechanical quick release
fastener systems
Locking/unlocking by quarter turn
Hand operated
Service-friendly, time-saving
and cost cutting
Vibration-resistant
-
-
-
-
-
Mechanical mounting of LL STAGE WASH
03.4 Control data connection
Control data cable length is specied by Norm IEC929 Annex E4.
It is not necessary to open the xture before connecting of DMX512 control sig-
nal. Interconnections are realized by Neutrik XLR 5pin In/Out connectors.
Pin connections:
Pin 1 – ground
Pin 2 – signal negative
Pin 3 – signal positive
-
-
-
03.5 DMX channels
These informations are subject to change, latest data are on: www.leaderlight.eu
05 MAINTENANCE AND SERVICE
Before any maintenance is necessary to carefully read all SAFETY INFORMATION 01!
Damages caused by inadequate cleaning or maintenance are not covered by warranty.
Requires periodic cleaning (dust, dirt ,...)
Procedure for maintenance:
Unplug mains before maintenance and at least 10 minutes cool off.
Appliance do not illegal open or demount.
Clean-up dust only from outer surface. Use vacuum or dumpy duster (warm
water)
Before reinstalling make sure everything is intact and dry– no wet parts!
Service:
Customer service provided by the manufacturer.
-
-
-
-
-
-
-
-
!
Ch
.RGBAW AW AWUV
Mode1: Dip2=Off
1 R 1, R 2, R 3 A 1, A 2, A 3 A 1, A 2, A 3
2 G 1, G 2, G 3 W 1, W 2, W 3 W 1, W 2, W 3
3B 1, B 2, B 3 Master (Dip1=On, Dip4=Off) UV 1, UV 2, UV 3
4 A 1, A 2, A 3 Strobo (Dip1=On, Dip4=Off) Master (Dip1=On, Dip4=Off)
5 W 1, W 2, W 3 Strobo (Dip1=On, Dip4=Off)
6Master (Dip1=On, Dip4=Off)
7Strobo (Dip1=On, Dip4=Off)
Mode4: Dip2=On
1 R 1 A 1 A 1
2 G 1 W 1 W 1
3B 1 A 2 UV 1
4 A 1 W 2 A 2
5 W 1 A 3 W 2
6 R 2 W 3 UV 2
7 G 2 Master (Dip1=On,Dip4=Off) A 3
8B 2 Strobo (Dip1=On, Dip4=Off) W 3
9 A 2 UV 3
10 W 2 Master (Dip1=On,Dip4=Off)
11 R 3 Strobo (Dip1=On, Dip4=Off)
12 G 3
13 B 3
14 A 3
15 W 3
16 Master (Dip1=On,Dip4=Off)
17 Strobo (Dip1=On, Dip4=Off)
Extention and control functions:
Dip4=Off, Dip1=Off =>DipBCD: use rotating switch for DMX start address
(RS1-100, RS2-010, RS3-001) from 001 to 512
Dip4=Off, Dip1=On: address+2channels (Master+Strobo)
Dip4=On, Dip1=Off: switch on AutoRun-table functions:
“100“=Prg.0-9, “10“=StepTime, “1“=FadeTime
Dip4=On, Dip1=On: switch all channels on 50% - test function
Dip2=Off: Mode 1 (5+2ch) Dip2=Off: Mode 1 (2+2ch) Dip2=Off: Mode 1 (3+2ch)
Dip2=On: Mode 4 (15+2ch) Dip2=On: Mode 4 (6+2ch) Dip2=On: Mode 4 (9+2ch)
Dip3=Off: standard curve
Dip3=On: ultraSoft curve
Mechanical mounting of tubus and frame to the LL STAGE WASH
Vario Optic installation
2.1 Fit the tube LL37 300 / LL37 303 part on top of tting. The tube screws screw into the tting holes.
The tube is ready to use.
Tube and frame installation without tools (Figures Nr. 2.1 to 2.2).
2.2 The frame must be installed together with tube
LL37 303
. The frame mount with screws on the
top of tube.
It is not necessary to open the xture for echange of Vario Optic (Figures Nr. 3.1 to 3.2).
3.2 Carefully remove the optic modul and insert the new one and x with screws.
3.1 The optic installation is easy and fast by 2 screws.
180°
AIMING POSSIBILITY
The xture could be aim to wish position with
adjustable bracket.
Mounting on stage is easy using various accessories as seen below (Figures Nr. 1.1 to 1.4). The brackets are connect by Camlocs.
1.1
Serial connection by LL36 600 for creation of continuous line
1.2 Serial connection by LL36 610 for creation of line with extension
1.4 Parallel connection by triple bracket LL36 6301.3 Parallel connection by dual bracket LL36 620
LL36 620 LL36 630
LL36 600 LL36 610
04 PERNAMENT USE LIMITATIONS FOR HEATING DISSIPATION
Pernament use limitations for heating dissipation of LL STAGE WASH RGBAW - body
temperature must be less then 55°C
40°C ambient temperature -20% of total power
30°C ambient temperature -10% of total power
20°C ambient temperature 0% of total power
Black version - 30%
Silver or White version - 50%
Example:
Then nal pernament value for BLACK colour and 40°C ambient temperature = -30% -20%
= 56% = max 143 ≥ (R + G + B + W +A) / 5
It‘s mean average of power go inside the xture at DMX signal
Example:
black LL STAGE WASH: 180 ≥ (R + G + B + W + A) / 5
silver LL STAGE WASH: 128 ≥ (R + G + B + W +A) / 5
Values for R or G or B or W or A is 100% = 256 = 8bit levels *** RED 50% = 128 value, RED
75% = 192 value
Final information we don’t drop down each colour power with temperature control to
get maximum for each colour under total recomendations , therefore you need setup
limitations from control desk !!!
-

This manual suits for next models

5

Other Leader Light Light Fixture manuals

Leader Light LL36 104 User manual

Leader Light

Leader Light LL36 104 User manual

Leader Light LL ARC MINI LINE WHITE Series User manual

Leader Light

Leader Light LL ARC MINI LINE WHITE Series User manual

Leader Light LL LED FLOOD NEO Z-POWER RGBAW User manual

Leader Light

Leader Light LL LED FLOOD NEO Z-POWER RGBAW User manual

Popular Light Fixture manuals by other brands

Microh ULTRA TRINITY330 user manual

Microh

Microh ULTRA TRINITY330 user manual

Maxim Lighting CounterMax MX-L-120-1K quick start guide

Maxim Lighting

Maxim Lighting CounterMax MX-L-120-1K quick start guide

Light Sky F400LL user manual

Light Sky

Light Sky F400LL user manual

Portfolio DUALBRITE 4291 user manual

Portfolio

Portfolio DUALBRITE 4291 user manual

Philips 69118-31-PH Specification sheet

Philips

Philips 69118-31-PH Specification sheet

Green Creative INNOFIT INFT4 installation guide

Green Creative

Green Creative INNOFIT INFT4 installation guide

Polarlite 1500203 operating instructions

Polarlite

Polarlite 1500203 operating instructions

Martin MAC Viper Wash user guide

Martin

Martin MAC Viper Wash user guide

MOOD SOL-410 instruction manual

MOOD

MOOD SOL-410 instruction manual

WHITECROFT LIGHTING Concert EX2S installation instructions

WHITECROFT LIGHTING

WHITECROFT LIGHTING Concert EX2S installation instructions

Intermatic AL406 Series Assembly procedures

Intermatic

Intermatic AL406 Series Assembly procedures

Castell Salvo Traffic Lights user guide

Castell

Castell Salvo Traffic Lights user guide

Eaton EUX Universal Edge Lit Exit Lens installation instructions

Eaton

Eaton EUX Universal Edge Lit Exit Lens installation instructions

Lightolier Tangent FXT4P specification

Lightolier

Lightolier Tangent FXT4P specification

Armstrong TechZone ML-TZ-DF brochure

Armstrong

Armstrong TechZone ML-TZ-DF brochure

ACME Xperior 5R BEAM F User giude

ACME

ACME Xperior 5R BEAM F User giude

Philips 69130-87-PH Specification sheet

Philips

Philips 69130-87-PH Specification sheet

DTS DIVE 6 user manual

DTS

DTS DIVE 6 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.