•Microprocessor based trim tab control with LED tab position indicators
• Completely sealed, completely waterproof and will not deteriorate in sunlight
• Tabs automatically retract and calibrate on key switch on or off
• Easy upgrade from rocker switch style control with BP-10 mounting plate
• No external power module required
• Automatically dims LED tab position indicators in darkness and brightens in sunlight
• Adjustable programming features located on back of specification sheet
• Operates up to 6 stations (Use 1 SR cable per Oval control for each station)
• Operates up to 2 actuators per tab on 12vdc and 4 actuators per tab on 24vdc systems
• Black or Gray color display available
FEATURES
Linear Devices Corporation
8790 Park Central Drive, Richmond, VA 23772
www.lectrotab.com, Ph 804-261-3888, Fax 804-264-3070
January 2011
The Oval control combines a microprocessor based trim
tab control with an LED tab position indicator. This control
incorporates automatic tab retraction and calibration
whenever the control power is switched on or off. This
unique design requires no feedback sensor for tab
position. LED indicators automatically dim at night and
brighten in sunlight. The Oval is completely sealed and
waterproof. Its rubberized cover is UV protected and will
not deteriorate in sunlight. The control switch is self-
contained and does not require an additional control box.
Lectrotab’s Oval control can be used as a single station or
can handle up to 6 stations in constant communication
with each other.
Oval LED Control
SPECIFICATIONS
Model
Number
Display
Color
Number of
Stations
Overall
Width
Overall
Height
Mounting
Hole Cutout
(Diameter)
DC
Voltage
Fuse Size
Power Input
(1 Actuators per Tab)
Fuse Size
Power Input
(2 Actuators per Tab)
Fuse Size
AUX Terminal
(MUST CONNECT)
SETR-61
Black
Up to 6 (Use 1 SR
Cable per SETR for
2 or more stations)
3.94"/
100mm
3.38"/
86mm
2"/51mm -
2.5"/63.5mm
12/24
12vdc = 20 amp
24vdc = 10 amp
12vdc = 30 amp
24vdc = 20 amp
.1 amp
SETR-60
Gray
Up to 6 (Use 1 SR
Cable per SETR for
2 or more stations)
3.94"/
100mm
3.38"/
86mm
2"/51mm -
2.5"/63.5mm
12/24
12vdc = 20 amp
24vdc = 10 amp
12vdc = 30 amp
24vdc = 20 amp
.1 amp
SETR-61 Oval Control
Linear Devices Corporation
8790 Park Central Drive, Richmond, VA 23772
www.lectrotab.com, Ph 804-261-3888, Fax 804-264-3070
January 2011
OVAL (SETR) PROGRAMMING
Enter, Adjust and Exit Program Mode:
•Before entering program mode, 12vdc or 24vdc must be applied to Oval main power
•Power to AUX terminal must be OFF (Aux is typically connected to ignition key switch or aux switch)
•Press and hold button noted in Oval Programming chart under column “Enter” for more than 2 seconds
while switching the Aux terminal switch to ON at the same time
•Release the “Enter” button and press “STBD BOW UP or DOWN” button to change the value
•Press and hold “PORT BOW UP” for more than 2 seconds to exit program mode
Program Mode Sequence
Function
Enter
Adjust
Exit
Range
Default
Program Details
Timing
PORT BOW DOWN
STBD BOW
DOWN/UP
PORT BOW UP
4 - 12sec
8sec
8 LED's = 8 second actuator
4 LED's = 4 second actuator
LED's On/Off
PORT BOW UP
STBD BOW
DOWN/UP
PORT BOW UP
On/Off
On
8 LED's = LED ON
1 LED = LED's OFF
Swap LED's
STBD BOW DOWN
STBD BOW
DOWN/UP
PORT BOW UP
LED's
Opposite of
button/same
side button
LED's
Opposite of
button press
1 LED on right and left = LED
lights opposite of button press
8 LED's on right and left = LED
lights same side as button press
OVAL (SETR) WIRING/INSTALLATION DIAGRAM
(-)
DC ground
Use 14ga. wire
Communications Port
for second station. See
Installation Manual
for details.
"OVAL " (SETR) Control Installation/Wiring Diagram
(+)12 or 24 VDC input power.
Use 14ga. wire.
12vdc = 15 or 20 amp fuse
24vdc = 10 amp fuse
This input voltage
must match the voltage rating
on the actuators being used.
Note (for S1):
"Oval" AUX terminal function:
1) Switch (S1) opens 12vdc power to initiate a
10 second tab retract and Oval control will
shut down.
2) Switch (S1) closes 12vdc power to initiate a
10 second tab retract and Oval control will
continue functioning.
3) The Aux terminal is typically connected to a
+12vdc source that is shut down after docking
to allow tabs to retract, recalibrate and prevent
damage.
(+) (-) AUX
BK
RD
GN
WH
GREEN
WHITE
BLACK
RED
BLACK
WHITE
BLACK
WHITE
Stbd Actuator
W4-** Interconnect
Cable
Port Actuator
BK
RD
GN
WH
W4-** (**=length) 4 conductor, 14 AWG
interconnect cable may be used or actuator
may be ordered with extended cable i.e.
A-BK-13 = 23 ft. (7m), A-BK-24 = 28 ft.
(8.5m) connecting to SETR.
Oval (SETR) Control
MUST CONNECT
(+)12 or 24 VDC
input power.
Use 16ga. wire min.
.1 amp Fuse
See Note
S1
OR
Use A-BK-13 or A-BK-24
extended cable from
actuator connecting
directly to SETR.
Port Actuator
Stbd Actuator
(+) (-) AUX
BK
RD
GN
WH
Oval (SETR) Control Dimensions
Port Actuator
Stbd Actuator
3.38
86mm
1.48
37.6mm
3.94
100mm
1.69
42.9mm
MUST CONNECT

Other manuals for Oval SETR-61

1

This manual suits for next models

2

Popular Remote Control manuals by other brands

RCA RCR4373N Troubleshooting

RCA

RCA RCR4373N Troubleshooting

Niles EVC-100 Specification sheet

Niles

Niles EVC-100 Specification sheet

Metroboard Mini RC instructions

Metroboard

Metroboard Mini RC instructions

Sony RMF-TX800U Quick reference guide

Sony

Sony RMF-TX800U Quick reference guide

VISA IT-9300 operating instructions

VISA

VISA IT-9300 operating instructions

LG Magic Remote AN-MR19BA quick start guide

LG

LG Magic Remote AN-MR19BA quick start guide

Panasonic EUR511510 Quick reference guide

Panasonic

Panasonic EUR511510 Quick reference guide

Long range MT4300-C instruction manual

Long range

Long range MT4300-C instruction manual

QL KeyFob manual

QL

QL KeyFob manual

Honeywell HCW 23 installation instructions

Honeywell

Honeywell HCW 23 installation instructions

RadioLink t8fb user manual

RadioLink

RadioLink t8fb user manual

Salus RR868 user manual

Salus

Salus RR868 user manual

RadioLink T4EU user manual

RadioLink

RadioLink T4EU user manual

Truth Sentry II operating instructions

Truth

Truth Sentry II operating instructions

AIRTRONICS MX-3X operating manual

AIRTRONICS

AIRTRONICS MX-3X operating manual

Viessmann Vitotrol 300-B Installation and service instructions for contractors

Viessmann

Viessmann Vitotrol 300-B Installation and service instructions for contractors

Magnavox MRU1400 - Universal Remote Control user guide

Magnavox

Magnavox MRU1400 - Universal Remote Control user guide

Mi-Light FUT087 User instruction

Mi-Light

Mi-Light FUT087 User instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.