LED IT REDA SOLAR User manual

Subject to change without notice.
REDA SOLAR User Manual
LED IT COMPANY LIMITED
Room A, 21/F, Gaylord Commercial building,
114 -118 Lochkart Road, Wanchai, Hong Kong
REDA SOLAR User Manual

Subject to change without notice.
REDA SOLAR User Manual
LED IT COMPANY LIMITED
Room A, 21/F, Gaylord Commercial building,
114 -118 Lochkart Road, Wanchai, Hong Kong
REDA SOLAR User Manual
20CM
1
Fix the two metal clips into position and attach to surface. It is recommended that each
clip is positioned approximately 20cm from each end of the REDA SOLAR.
Caution: Ensure correct anchor sleeves are used for surface material.
Please see package contents before installation.
Insert Tensioning Bolt and attach the
REDA SOLAR to the metal clips
Connect the MC4 Connectors to the Solar panel.
Note : A matching pair of MC4 connectors
are included in the contents of this
package. If the Solar Panel does
NOT have an identical pair of MC4 connectors,
replace them with the ones provided to
guarantee a weather tight connection.
Using a screw driver, secure each clip onto the
REDA SOLAR with the Tensioning bolt.
Note : This is only to secure the REDA SOLAR, so it cannot
be removed - Do not stress it tightening it too much.
Power ON the REDA SOLAR. A RED signal light
can be seen at the sensor end of the REDA SOLAR.
Program the light to best suit your installation.
Please refer to setup guide of manual properly.
Light will work at 50% power when nobody
there and 100% power for 60 seconds when
sensor is triggered by someone passing by.

Subject to change without notice.
REDA SOLAR User Manual
LED IT COMPANY LIMITED
Room A, 21/F, Gaylord Commercial building,
114 -118 Lochkart Road, Wanchai, Hong Kong
REDA SOLAR User Manual
This is to fix to solar panel
M6෪16 Screws Can fix in different holes for different mounting angle
M6෪16 Screws
M8෪16 Screws
*Please note the brackets for left and right sides are different, make sure it is assembled properly.

Subject to change without notice.
REDA SOLAR User Manual
LED IT COMPANY LIMITED
Room A, 21/F, Gaylord Commercial building,
114 -118 Lochkart Road, Wanchai, Hong Kong
REDA SOLAR User Manual
Finished assembly

Subject to change without notice.
REDA SOLAR User Manual
LED IT COMPANY LIMITED
Room A, 21/F, Gaylord Commercial building,
114 -118 Lochkart Road, Wanchai, Hong Kong
REDA SOLAR User Manual
Magic Remote Control Manual
Time Zone
Modes Zone
ON/OFF override button. 100% Light Output
Auto Function (Not Used). By Default Auto Function is programmed ON. (Auto OFF During Day, Auto ON During Night)
Test Function. Light will operate for 20 seconds.
- The red indicator light will operate inside the end-cap if the battery is low / over-discharged.
Light Output 0%. When sensor triggered - Light Output 100% for 1 minute.
5-6-7-8-9 are similar time function as 1-2-3-4....
Light Output 30%. When sensor triggered - Light Output 100% for 1 minute
Light Output 50%. When sensor triggered - Light Output 100% for 1 minute.
Light Output 100% (First 6 hrs). Light Output 50% (Second 6 hrs) - When sensor is triggered - Light Output 100% for 1 minute.
* Helpful Hint. Press “D” and a Time Setting (e.g.7H) = 100% for 3.5 hours then 50% for next 3.5 hours + 100% with sensor.
- Amount of Light output depends on the percentage selection.
- By default the light will operate for 12 Hours.
* Helpful Hint.
Select a Time Setting (e.g. 4H) within 5 seconds
to modify the default operating time.
Constant light mode
- By default the light will operate for 12 Hours.
* Helpful Hint. Select a Time Setting (e.g. 9H)
within 5 seconds to modify the default
operating time.
- Light Duration based on selection.
* Helpful Hint.
- Select 20% then 4H. Light will operate at 20% for 4 Hours.
- Select C then 8H. Light will operate at 50% for 8 Hours + 100% if sensor triggered.
- Select D then 3H. Operate at 100% for 1.5 Hours, 50% for 1.5 Hours + 100% with sensor.
Time Setting mode
The magic remote control is specially developed for solar luminaries. It offers a combina-
tion of many lighting modes to satisfy a wide variety of different lighting applications. In
addition to allowing users to easily set the power @ 20%, 40%, 60% or 100%, it also
changes the lighting time from 1 hour to 12 hours.
It comes with 4 different lighting modes (A, B, C and D) built-in. Users can set their own
lighting mode, and press the button of Time zone to set the time. This remote also
supports lighting during the day time while the luminaire is being charged by solar panel.
It even works for indoor lighting perfectly.
REMOTE CONTROL

Subject to change without notice.
REDA SOLAR User Manual
LED IT COMPANY LIMITED
Room A, 21/F, Gaylord Commercial building,
114 -118 Lochkart Road, Wanchai, Hong Kong
REDA SOLAR User Manual
*After turning the REDA SOLAR ON. A Red/Green/Blue status light will cycle for two seconds
then stop. This signals the REDA SOLAR system is OK and will work in the default operation of
0%+100% sensitivity power surface material. Please see package contents before installation.
*After 1 minute of being ON a BLUE light will start to ash slowly. This signal means the REDA SOLAR is in a
charge state, the solar panel is connected and operated as it should.
IMPORTANT:
If the BLUE light ashes quickly after 1 minute, check the polarity connection between the solar panel and
REDA SOLAR: positive cables together and negative cables together with a rm stable contact made.
TESTING
To simulate the REDA SOLAR operation during daylight hours Disconnect or cover the Solar Panel (This
signals no voltage present to the REDA SOLAR, and will simulate night operation) – Now turn REDA
SOLAR ON. The Red/Green/Blue status lights will cycle for two seconds then stop. After 40 seconds,
move in proximity of the microwave sensor, once detected by the microwave sensor the light will
operate with 100% light output (default setting) then will turn off automatically after 30 seconds.
PLEASE NOTE:
The default setting is Mode A with 0% power (No Light Output) and 100% Light Output when a person is in
proximity. You can press buttons B, C or D or 20%, 40%, 80% to turn light ON immediately to check light condition.
USING THE REMOTE
The remote uses microwave (IR) technology and needs to be used in the same way as a TV –You must point
the remote directly at the REDA SOLAR to send a command. After pressing a button on the remote control,
you will see a GREEN + BLUE light for two seconds. That signals a command has been received successfully.
Note: Refer to manual for remote control functions and programming.
HOW TO FIX COMMON PROBLEMS
BLUE LIGHT NOT VISIBLE
Once you have followed the steps under General Operation, if the Blue light is not
ashing at all, please double check that there is a solid and stable connection between
the REDA SOLAR and the Solar Panel, and that the polarity is correct.
• Meter the voltage from the solar panel to the MC4 connectors. Ensure the voltage
is no less than 15Vdc and that the connectors inside MC4 are not loose.
GREEN SIGNAL LIGHT FLASHING FAST
• If the GREEN light is ashing-fast, this signals an over-discharged battery state. In this situation,
carry out a full charge using the solar panel sized for the installed REDA SOLAR.
This can take up to 6 hours for a full charge depending on panel size.
RED/GREEN/BLUE STATUS LIGHT
Table of contents
Popular Solar Panel manuals by other brands

HeimVision
HeimVision HMS1 quick start guide

Phono Solar
Phono Solar F Type module installation manual

Viessmann
Viessmann Vitosol 222-T Operating Instructions for the System User

Conrad
Conrad Multi 300 operating instructions

COMFORTPOOL
COMFORTPOOL CP-80021 Installation & operation manual

Beretta
Beretta SCF-V25 installation manual