Artnet-DMX converter is the Ethernet Control System based on the Artnet protocol, used to convert the Artnet network data
package into DMX512 data, adopting high-speed ARM processor, stable and reliable working. Following Artnet standard
protocol, it supports RJ45 network interface and standard DMX512 output interface.
Artnet-DMX-8 use standard 1U(19" ) chassis architecture, convenient installation in professional cabinet, easily operation
setting with LCD display.
Artnet-DMX-8 provides 8 standard DMX512 data output port, total output 8×512 data.
It is compatible with all the effects lighting control software which support Art-net protocol, widely used in the LED dot matrix
and the stage lighting control network in needing lots of DMX-512 data, especially for TV station recorded scene, stage
performances, entertainment and so on.
44mm
1. Based on Artnet protocol network data communication, accept network DMX data.
2. Two different IP address for each controller
3. Send packets to the network by broadcast mode
4. Manage Artnet on broadcast mode or unicast mode
5. Standard 1U(19" ) chassis architecture, convenient installation in the standard cabinet.
6. With LCD screen display, convenient operation intuitive settings
7. Provides 8 standard DMX512 data output port,output 8×512 data in total.
8. Set different network segments to avoid multiple sets Artnet data interference.
9. Compatible with the light software based on Artnet Protocol, control stage lighting and LED lighting simultaneously.
Artnet-DMX-8
DMX512
AC100-240V (with a power adaptor)
L482.6×W200×H44mm
L550×W265×H100mm
2200g
-20 ~65℃ ℃
Artnet
8 512 × channels
440mm
200mm
482.6mm
1
23
PUSH
DMX 8 Ethernet DC12V
1
23
PUSH
DMX 7
1
23
PUSH
DMX 6
1
23
PUSH
DMX 5
1
23
PUSH
DMX 4
1
23
PUSH
DMX 3
1
23
PUSH
DMX 2
1
23
PUSH
DMX 1
Artnet-DMX-8
WELCOME
DMX output1-8 Artnet input Power input
OFF/ON
Menu button
(Exit button)
Set button
(Save button)
LCD Monitor -Button
+Button
Status lamp
(there will be flicker when data transfer)
Back
Front
One IP manage 1 Subnet and 4 Universe addresses, that is one IP manage 4 output ports
(see the below table)
The calculation method of DMX group address: Group address=Subnet*16 + Universe
:
For example: Subnet for Node 1 is 2, Outlet: Univ for 2 is 8, then Outlet: the group address of 2 is Address=2*16+8=40
IP Subnet(0~15) Universe(0~15)
remark: Two IP address can not be set to the same value to avoid the controller is not working properly caused by IP conflict.
No de 1 I P
2 . 0 . 0 . 2
No de 1 I P
2 . 0 . 0 . 3
No de 1
Subnet: 0
No de 2
Subnet: 0
Ou tl et : 1
Univ: 0
Ou tl et : 5
Univ: 4
Ou tl et : 2
Univ: 1
Ou tl et : 6
Univ: 5
Ou tl et : 3
Univ: 2
Ou tl et : 7
Univ: 6
Ou tl et : 4
Univ: 3
Ou tl et : 8
Univ: 7
Other Functions of Button:
Main
interface
Press the menu button in the main interface to enter the menu interface(see the below table).
Press the +/- button / to move up and down the menu and set the relative parameter through press the setting
button . Press the +/- button / can increase or decrease the parameter. Press the setting button to
save the setting when finished and press the menu button to quit the setting status.
Button Operating Instructions:
1. Technical Specs
2. Performance Features
Output signal
Power input
Working temperature
Dimension
Package Size
Weight (G.W)
Input signal
DMX channels
3. Product dimension
4. Interface instruction
In the main interface, long press the setting button to enter test mode (send the dark, light and
highlighting skipping data changing effect to the 8 ports). Press the menu button or setting button to quit the
test mode.In the main interface, long press the +/- button / at the same time to restore factory settings.
Test Mode
warranty
5 years
Контроллер LT-Artnet-DMX-8
(220V, 4096CH)
3 4
1
23
PUSH
DMX 8 Ethernet DC12V
1
23
PUSH
DMX 7
1
23
PUSH
DMX 6
1
23
PUSH
DMX 5
1
23
PUSH
DMX 4
1
23
PUSH
DMX 3
1
23
PUSH
DMX 2
1
23
PUSH
DMX 1
CAT5 Ethernet Switch
1
23
PUSH
DMX 8 Ethernet DC12V
1
23
PUSH
DMX 7
1
23
PUSH
DMX 6
1
23
PUSH
DMX 5
1
23
PUSH
DMX 4
1
23
PUSH
DMX 3
1
23
PUSH
DMX 2
1
23
PUSH
DMX 1
1
23
PUSH
DMX 8 Ethernet DC12V
1
23
PUSH
DMX 7
1
23
PUSH
DMX 6
1
23
PUSH
DMX 5
1
23
PUSH
DMX 4
1
23
PUSH
DMX 3
1
23
PUSH
DMX 2
1
23
PUSH
DMX 1
1
23
PUSH
DMX 8 Ethernet DC12V
1
23
PUSH
DMX 7
1
23
PUSH
DMX 6
1
23
PUSH
DMX 5
1
23
PUSH
DMX 4
1
23
PUSH
DMX 3
1
23
PUSH
DMX 2
1
23
PUSH
DMX 1
100-240V AC
CAT5
CAT5
CAT5
Artnet-DMX-8
Artnet-DMX-8
Artnet-DMX-8
Artnet-DMX-8
CAT5
100-240V AC
100-240V AC
100-240V AC
Moving head light
Par light
LED light
Spot light
1
23
PUSH
DMX 8 Ethernet DC12V
1
23
PUSH
DMX 7
1
23
PUSH
DMX 6
1
23
PUSH
DMX 5
1
23
PUSH
DMX 4
1
23
PUSH
DMX 3
1
23
PUSH
DMX 2
1
23
PUSH
DMX 1
1
23
PUSH
DMX 8 Ethernet DC12V
1
23
PUSH
DMX 7
1
23
PUSH
DMX 6
1
23
PUSH
DMX 5
1
23
PUSH
DMX 4
1
23
PUSH
DMX 3
1
23
PUSH
DMX 2
1
23
PUSH
DMX 1
1
23
PUSH
DMX 8 Ethernet DC12V
1
23
PUSH
DMX 7
1
23
PUSH
DMX 6
1
23
PUSH
DMX 5
1
23
PUSH
DMX 4
1
23
PUSH
DMX 3
1
23
PUSH
DMX 2
1
23
PUSH
DMX 1
100-240V AC
CAT5
CAT5
Artnet-DMX-8
Artnet-DMX-8
Artnet-DMX-8
100-240V AC
100-240V AC
Wall Washer
Tube
CAT5
CAT5
8x512
8x512
8x512
8x512
8x512
8x512
8x512
Moving head light Moving head light
Par light Par light
LED light LED light
Spot light Spot light
Wall Washer Wall Washer
Tube Tube
Spot light Spot light Spot light
6. Attention
7. Warranty Agreement
★ This manual only applies to this model. Ltech reserves the right to make changes without prior notice.
1. We provide lifelong technical assistance with this product:
● A 3 year warranty is given from the date of purchase. The warranty is for free repair or replacement and covers manufacturing faults only.
● For faults beyond the 3 year warranty we reserve the right to charge for time and parts.
2. Warranty exclusions below:
● Any man-made damages caused from improper operation, or connecting to excess voltage and overloading.
● The product appears to have excessive physical damage.
● Damage due to natural disasters and force majeure.
● Warranty label, fragile label and unique barcode label have been damaged.
● The product has been replaced by a brand new product.
3. Repair or replacement as provided under this warranty is the exclusive remedy to the customer. Ltech shall not be liable for any incidental
or consequential damages for breach of any stipulation in this warranty.
4. Any amendment or adjustment to this warranty must be approved in writing by Ltech only.
1. The product shall be installed and serviced by a qualified person.
2. This product is non-waterproof. Please avoid the sun and rain. When installed outdoors please ensure it is mounted in a water proof
enclosure.
3. Good heat dissipation will prolong the working life of the controller. Please ensure good ventilation.
4. Please check if the output voltage of any LED power supplies used comply with the working voltage of the product.
5. Please ensure that adequate sized cable is used from the controller to the LED lights to carry the current. Please also ensure that the
cable is secured tightly in the connector to avoid the accidents due to overheat and poor contact on the wire.
6. Ensure all wire connections and polarities are correct before applying power to avoid any damages to the LED lights.
7. If a fault occurs please return the product to your supplier. Do not attempt to fix this product by yourself.
5. Conjunction diagram

Popular Controllers manuals by other brands

Johnson Controls PENN P28 installation instructions

Johnson Controls

Johnson Controls PENN P28 installation instructions

Carrier CCU Control manual

Carrier

Carrier CCU Control manual

HKC ET Series Installation, operation & maintenance manual

HKC

HKC ET Series Installation, operation & maintenance manual

Mitsubishi Electric PAC-YT51CRB Operation manual

Mitsubishi Electric

Mitsubishi Electric PAC-YT51CRB Operation manual

EWM M1.83-B-1 operating instructions

EWM

EWM M1.83-B-1 operating instructions

Generac Power Systems Digital Controller R-200A Technical manual

Generac Power Systems

Generac Power Systems Digital Controller R-200A Technical manual

Sealey SUPERSTART300.V5 instructions

Sealey

Sealey SUPERSTART300.V5 instructions

Siemens SIMATIC S7 manual

Siemens

Siemens SIMATIC S7 manual

DKM Motor Co., Ltd. FX3000 manual

DKM Motor Co., Ltd.

DKM Motor Co., Ltd. FX3000 manual

THORLABS LD2000 operating manual

THORLABS

THORLABS LD2000 operating manual

Russound ALTX SC instruction manual

Russound

Russound ALTX SC instruction manual

Leb Electronics CTR50 instruction manual

Leb Electronics

Leb Electronics CTR50 instruction manual

AUMA SV 05.1 Operation instructions

AUMA

AUMA SV 05.1 Operation instructions

Eaton Cutler-Hammer ELC Series Basic training manual

Eaton

Eaton Cutler-Hammer ELC Series Basic training manual

ABB 650 series Engineering manual

ABB

ABB 650 series Engineering manual

Leviton miniZ mZn20-102 user guide

Leviton

Leviton miniZ mZn20-102 user guide

NEC PF5820 installation guide

NEC

NEC PF5820 installation guide

bentrup TC 707 operating instructions

bentrup

bentrup TC 707 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.