Leica FLEXACAM C1 User manual

FLEXACAM C1
12 MP Stand-Alone
Microscope Camera
User Manual

FLEXACAM C1 User Manual 2
Contents
General Notes
General Notes 5
Important Safety Notes 6
Symbols Used 7
Safety Instructions 8
End User License Agreement (EULA) 11
Introduction
Congratulations! 13
Standard Delivery and Optional Accessories 14
Optional Accessories 15
Overview of the Instrument 16
Assembly
Assembling the Camera 18
Stand-Alone Operation Installation / Setup / Application
Cables and Terminals in HD Mode (Stand-Alone) 20
Switching on the FLEXACAM C1 21
Information About Thumb Drive/ USB Stick 22
Using the USB Thumb Drive as a Memory Device 23
Configuring the USB Wireless Mouse 24
Configuring the Footswitch 25
Capturing Images Without a Computer 26
Capturing Movies Without a Computer 27
White Balance 28
Menu of GALLERY View 29
PC Operation Installation / Setup / Application
Connecting a Computer, Installing Software, Activating PC Mode 31
Switching on the FLEXACAM C1 32
Additional Parallel Use of an HD/ 4K Monitor 33
User Menu – On-Screen Display (OSD)
On-Screen Display (OSD) 35
Calling up and Closing the User Menu / OSD 36
CONTROL Menu 38
SETTINGS Menu 40
Menu of GALLERY View 42
Settings Network 43
Care and Maintenance
Care, Maintenance, Contact Persons 46
Spare Parts 49

FLEXACAM C1 User Manual General Notes 4
General Notes

FLEXACAM C1 User Manual General Notes 5
General Notes
Safety concept
Before using your Leica microscope camera for
the first time, please read the "Safety Concept"
booklet included with your instrument. It
contains additional information on handling
and care.
Cleaning
ODo not use any unsuitable cleaning agents,
chemicals or techniques for cleaning.
ONever use chemicals to clean colored
surfaces or accessories with rubberized
parts. This could damage the surfaces,
and specimens could be contaminated by
abraded particles.
OFollow the notes regarding cleaning the
filter glass in the service section.
OIn most cases it is OK to use a wipe damp-
ened with 70 % ethanol in distilled water.
Servicing
ORepairs may only be carried out by Leica
Microsystems-trained service technicians.
Only original Leica Microsystems spare
parts may be used.
Responsibilities of person in charge of
instrument
OEnsure that the Leica microscope camera
is operated, maintained and repaired by
authorized and trained personnel only.

FLEXACAM C1 User Manual General Notes 6
Important Safety Notes
User manual
The FLEXACAM C1 microscope camera can be
configured in a variety of ways in the Leica
product range. You can find information on
individual system components on the inter-
active CD-ROM together with all relevant user
manuals in additional languages. Keep this
CD-ROM in a safe place, where it is available
to the user. User manuals and updates are also
available for you to download and print from
our web site at www.leica-microsystems.com.
This user manual describes the special functions
of the FLEXACAM C1 and contains important
instructions for operating safety, maintenance
and the accessory parts.
The "Safety Concept" booklet contains addi-
tional safety information regarding the service
work, requirements and the handling of the
microscope camera, accessories and electrical
accessories as well as general safety instruc-
tions.
You can combine individual system articles
with articles from external suppliers (e.g. cold
light sources, etc.). Please read the User Manual
and the safety instructions from the supplier.
Before installing, operating or using the instru-
ments, read the user manuals listed above. In
particular, please follow all safety instructions.
To maintain the unit in its original condition
and to ensure safe operation, the user must
follow the instructions and warnings contained
in these user manuals.

FLEXACAM C1 User Manual General Notes 7
Symbols Used
Read and understand this user
manual before using this device.
Warning! Safety hazard!
This symbol indicates especially impor-
tant information that is mandatory to
read and observe. Failure to comply can cause
the following:
OPersonal injury!
OInstrument malfunctions and damage.
Warning of hazardous electrical voltage
This symbol indicates especially impor-
tant information. Failure to comply can
cause the following:
OPersonal injury!
OInstrument malfunctions and damage.
Instrument malfunctions and damage
This symbol warns against touching hot
surfaces, such as light bulbs.
Important information
This symbol indicates additional infor-
mation or explanations that are intended
to provide clarity.

FLEXACAM C1 User Manual General Notes 8
Safety Instructions
Description
OThe individual modules fulfill the high
requirements for observation and docu-
mentation of the FLEXACAM C1 microscope
camera.
Intended use
ORefer to "Safety Concept" booklet
Non-intended use
ORefer to "Safety Concept" booklet
Never use the FLEXACAM C1 or its components
for diagnostic procedures if it is not expressly
intended for such use.
The instruments and accessories described in
this User Manual have been tested for safety
and potential hazards.
The responsible Leica affiliate must be consul-
ted whenever the instrument is altered, modi-
fied or used in conjunction with non-Leica
components that are outside of the scope of
this manual!
Unauthorized alterations to the instrument or
noncompliant use shall void all rights to any
warranty claims.
Place of use
ORefer to "Safety Concept" booklet
OElectrical components must be placed at
least 10 cm away from the wall and from
flammable substances.
OAvoid large temperature fluctuations, direct
sunlight and vibrations. These conditions
can distort the functionality of the camera.
OIn warm and damp climates, the individual
components require special care in order to
prevent the build-up of fungus.
Responsibilities of person in charge of
instrument
ORefer to "Safety Concept" booklet
Ensure that:
OThe FLEXACAM C1 and accessories are
operated, maintained and repaired by
authorized and trained personnel only.
OAll operators have read, understood and
observe this User Manual, and particularly
the safety regulations.

FLEXACAM C1 User Manual General Notes 9
Safety Instructions (Continued)
Repairs, service work
ORefer to "Safety Concept" booklet
OOnly original Leica Microsystems spare
parts may be used.
OBefore opening the instruments, switch off
the power and unplug the power cable.
OAvoid contact with powered electrical
circuits, which can lead to injury.
Transport
OBefore shipping the camera, please reset
the device to the factory default, so that no
personal data like access details to E-Mail or
network remain stored on the device.
OUse the original packaging for shipping or
transporting the individual modules of the
FLEXACAM C1 and the accessory compo-
nents.
OIn order to prevent damage from vibrations,
disassemble all moving parts that (accord-
ing to the user manual) can be assembled
and disassembled by the customer and
pack them separately.
Integration in third-party products
ORefer to "Safety Concept" booklet
Disposal
ORefer to "Safety Concept" booklet
Legal regulations
ORefer to "Safety Concept" booklet
EC Declaration of Conformity
ORefer to "Safety Concept" booklet
Health risks
Workplaces with microscopes facilitate and
improve the viewing task, but they also impose
high demands on the eyes and muscles of the
user. Depending on the duration of uninter-
rupted work, asthenopia and musculoskeletal
problems may occur. For this reason, appro-
priate measures for reduction of the workload
must be taken:
OOptimal arrangement of workplace, work
assignments and work flow (changing tasks
frequently).
OThorough training of the personnel, giving
consideration to ergonomic and organiza-
tional aspects.
The ergonomic optical design and construction
of Leica microscopes are intended to reduce the
exertion of the user to a minimum.

FLEXACAM C1 User Manual General Notes 10
Safety Instructions (Continued)
Instrument safety and EMC
Our device has been designed, produced and
tested in compliance with
OEN 60950-1: Information technology equip-
ment – Safety – Part one: general require-
ments
ORadio interference suppression in compli-
ance with EN 55011 class B
OEN 61326-1, Electrical equipment for
measurement, control and laboratory use –
EMC requirements
The device meets the requirements of EU
directives
O2014/35/EU Low voltage directive
O2014/30/EU EMC directive
O2011/65/EU RoHS directive
O2009/125/EC + VO EU 1194/2012
Ecodesign requirements for energy-related
products
and carries the CE mark.
The device must be disposed of in
accordance with 2012/19/EU WEEE
directive.
Intended for indoor use only in all EU member
states, EFTA states and Switzerland.

FLEXACAM C1 User Manual General Notes 11
End User License Agreement (EULA)
This End User License Agreement is entered
into by and between Leica Microsystems
("Leica") and you, the end user, as the context
requires, either individually or as an authorized
representative of the company or organization
acquiring and/ or using this device ("User").
This device can be used in a network and offers
functionality such as automated submission of
images to an E-Mail recipient defined by the
User, or copying of images to a SMB file server
selected by the User. Therefore, passwords will
need to be chosen by the User which passwords
will be stored on the device in a separate pass-
word file. Direct access to the password file is
denied; passwords are stored with an encryp-
tion which follows the Advanced Encryption
Standard (AES), with a block and key size of
128 bits.
During any firmware update this password file
will be deleted and the User will need to reenter
the passwords.
When sending or forwarding the device to third
parties for any reason, or when returning the
device to Leica for service or maintenance, the
User should always reset the device to factory
settings.
Use of network and/ or other connectivity func-
tionality provided by or with this device are at
the User´s discretion and risk; specifically, the
User assumes full responsibility for network
operation and safety. Leica does not guaran-
tee any particular network safety standard and
declines all responsibility, without limitation,
for unauthorized access, security breach, data
loss or corruption, or any financial or legal
consequences thereof.

FLEXACAM C1 User Manual Introduction 12
Introduction

FLEXACAM C1 User Manual Introduction 13
We congratulate you on purchasing the
FLEXACAM C1 microscope camera from Leica
Microsystems.
Real 4K display
The integrated HDMI output allows the camera
image to be displayed on a high-definition
(HD-capable) monitor, where the following
resolutions are possible:
O3,840 × 2,160 (4K UHD). To be used on 4K
monitors.
O1,920 × 1,080 (Full-HD). This resolution
provides the characteristic imaging perfor-
mance for a Full-HD-capable monitor.
Leica Application Suite X (LAS X)
Your FLEXACAM C1 includes a quickstart guide
with a download link to the latest "Leica Appli-
cation Suite X" software.
User-friendly even in the smallest detail
Like every digital camera, the FLEXACAM C1
reacts differently to different light sources.
However, the white balance is set with Leica
LED illumination at the factory.
Therefore, we recommend to use Leica LED
illumination.
Congratulations!

FLEXACAM C1 User Manual Introduction 14
Standard delivery
Standard delivery of the FLEXACAM C1 includes:
1. FLEXACAM C1 microscope camera
2. USB C cable, for connecting to a computer or
to a power supply unit
Optional "stand-alone kit"
3. 4K HDMI cable, for connecting to an HD / 4K
monitor
4. USB power supply
5. USB thumb drive as storage device
6. Wireless USB mouse
Standard Delivery and Optional Accessories
Additional information about working
on the computer and with Leica Applica-
tion Suite X is provided in the software's online
help.
2
4
5
3
6
1

FLEXACAM C1 User Manual Introduction 15
Optional Accessories
Hand/ footswitch
Various functions can be assigned to the
optional hand / footswitch (such as taking indi-
vidual pictures, white balance, video recording).
For information on additional accessories, such
as objectives and adapters, illumination or the
dust cover for the microscope, please contact
your Leica Microsystems authorized dealer.
You can find detailed descriptions of
different accessories in their correspond-
ing user manual.
Wi-Fi dongle
The Wi-Fi dongle enables you to work under
wireless condition with the FLEXACAM C1.
Due to different country restrictions, there are
different versions of Wi-Fi dongles available.
To get the latest information about the
availability of Wi-Fi dongles in your specific
country, please contact your local sales repre-
sentative.

FLEXACAM C1 User Manual Introduction 16
Overview of the Instrument
1. Ethernet connection
2. USB mouse connection,
keyboard connection, or Wi-Fi dongle
3. ON / OFF switch
4. PC /power supply connection
5. Connection for footswitch
6. Monitor (stand-alone)
7. For stand-alone operation, insert USB stick
for data storage here
7
6
1
54
2
3
2

FLEXACAM C1 User Manual Assembly 17
Assembly

FLEXACAM C1 User Manual Assembly 18
The FLEXACAM C1 is mounted on a
tube or on a microscope's photo port
using a C-mount adapter.
The FLEXACAM C1 is compatible with
most stereo, macro and light micro-
scopes from Leica Microsystems.
Assembly
1. Screw the camera onto a C-mount adapter.
2. Place the camera on the microscope's
photo port or the tube using the previously
mounted C-mount adapter.
Assembling the Camera
1
2 2

FLEXACAM C1 User Manual Stand-Alone Operation Installation / Setup / Application 19
Stand-Alone Operation
Installation / Setup / Application
Note: The screenshots of the on-screen display shown in this user manual are in English, but during operation the display will be shown
in the language selected by the user.

FLEXACAM C1 User Manual Stand-Alone Operation Installation / Setup / Application 20
General notes
The FLEXACAM C1 is designed for the
use of 4K and HD-capable (high defini-
tion) monitors. We recommend connecting the
HD / 4K monitor using an HDMI connector and
not using any adapters (e.g. DVI), as otherwise
proper function can no longer be guaranteed!
Please only connect the provided
5 V power supply unit. Using an incor-
rect voltage can substantially damage the
FLEXACAM C1.
The color of the LED indicates that the power
supply is not sufficient: it's red when the supply
doesn't provide enough current and it automa-
tically turns off the 3 USB ports.
Power supply and HD / 4K monitor
1. Connect the FLEXACAM C1 to a suitable
power socket using the supplied power
supply.
2. Connect the FLEXACAM C1 to the HD / 4K
monitor using the HDMI cable. The camera
detects automatically the monitor and
displays a live image.
3. To acquire images a USB Stick with suffi-
cient free memory must be inserted into
the FLEXACAM C1. To reach the highest
possible data transfer please use the USB
connection marked with "SPEED".
4. Make sure that a USB mouse is connected
to the FLEXACAM C1 in order to operate the
on-screen display.
Cables and Terminals in HD Mode (Stand-Alone)
1 2
3
4
Table of contents
Other Leica Digital Camera manuals