Leitch FR-6004 User manual

For Service, please contact your local representative or:
Leitch Europe Leitch Inc. Leitch Asia
Holland Park House 111 Galway Place Unit 306B
Oldbury Teaneck, NJ 07666 HK Industrial Technology Centre
Bracknell, Berkshire USA 72 Tat Chee Avenue
ENGLAND Kowloon Tong
RG12 8TQ HONG KONG
Tel: +44 (0) 1344 446 000 +1 201 833 8083 +852 2776 0628
Fax: +44 (0) 1344 446 100 +1 201 833 8089 +852 2776 0227
All efforts have been made to ensure the accuracy of this manual. Should any errors be
noticed, please notify the above.
© Leitch Technology International Inc. 1999
The copyright in this document is the property of Leitch Technology International Inc and it may
not be copied, reproduced, used for manufacture, nor the contents divulged without the express
permission in writing of Leitch Technology International Inc.
All Rights Reserved.
FR-6004 USER MANUAL
4U RACK AND POWER SUPPLY

Warranty
This Leitch product is warranted against defects in materials and workmanship for a period of
one year from the date of invoice. During the warranty period, Leitch will, at its option, either
repair or replace products which prove to be defective.
The warranty shall not apply to defects resulting from improper or inadequate maintenance by
Buyer, Buyer-supplied software or interfacing, unauthorised modification or misuse, operation
outside of the environmental specifications for the product, or improper site preparation or
maintenance.
Safety Considerations
General
This product and related documentation must be reviewed for familiarisation with safety
markings and instructions before operation. This product has been designed and tested in
accordance with international standards.
Safety Symbols
Indicates hazardous voltages
Indicates earth (ground) terminal
The WARNING sign denotes a hazard. It calls attention
to a procedure, practice, or the like, which, if not performed or
adhered to, could result in personal injury. Do not proceed
beyond a WARNING sign until the indicated conditions are
fully understood and met.
The CAUTION sign denotes a hazard. It calls attention to
an operating procedure, practice, or the like, which if not
correctly performed or adhered to, could result in damage to
or destruction of part or all of the product. Do not proceed
beyond a CAUTION sign until the indicated conditions are
fully understood and met.
Safety Earth Ground
This is a Safety Class 1 product (provided with a protective earthing terminal). An
uninterruptible safety earth ground must be provided from the main power source to the product
input wiring terminals, power, cord, or supplied power cord set. Whenever it is likely that the
protection has been impaired, the product must be made inoperative and secured against any
unintended operation.

Before Applying Power
Verify that the product is configured to match the available main power source per the input
power configuration instructions provided in this manual.
Servicing
These servicing instructions are for use by qualified personnel only. To reduce the risk of
electric shock, do not perform any servicing other than that contained in the Operating
Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.
Adjustments described in this manual may be performed with power supplied to the product
while protective covers are removed. Energy available at many points may, if contacted, result
in personal injury.
Capacitors inside this product may still be charged even when disconnected from their power
source. To avoid a fire hazard, only fuses with the required current rating and of the specified
type (normal blow, time delay, etc.) are to be used for replacement.

CONTENTS
1. GENERAL DESCRIPTION ........................................................................................... 6
2. INSTALLATION............................................................................................................ 7
3. SPECIFICATION .......................................................................................................... 8

Document Number: 6004ÚM.doc Issue 10
15th November 2000
6
1. General Description
The 6004T/C 4U chassis is designed to house up to sixteen vertically mounted Genesis cards.
The unit is designed to be as versatile and comprehensive as possible. This encompasses the
need for a modular platform to easily accommodate a wide variety of card and connector types
and to be quickly configurable. The unit has backup power supplies, remote alarms,
temperature sensing and forced air cooling.

Document Number: 6004ÚM.doc Issue 10
15th November 2000
7
2. Installation
To install the 6004T/C the following items are needed:-
6004T/C 4U rack
6094C Power Supply Module
IEC mains cable (10A 250Vac)
a) Remove all packing material.
b) Check that the correctly rated fuse is installed (6.3A slow blow 240Vac) in each IEC
mains inlet. The fuse can be found inside the IEC mains inlet on the rear of the unit.
c) Plug in the auto voltage sensing (115-230VAC) 6094C PSUs ensuring that they are
fully pushed home.
d) To connect up the PSU alarm. This is located on the right hand side of the rack
(Marked as Monitor). The pin out is as follows:
Pin 3
closure on fail - PSU 1
Pin 4
Pin 1
closure on fail - PSU 2
Pin 2
e) Close the front door.
f) Ensure that the front and rear vents have sufficient clearance to allow air to flow from
the front to the rear of the unit. The front and rear vents must never be covered when
the rack is powered up. For optimum performance ensure at all times that filters are
kept clean.
g) Connect up the supplied IEC mains leads and apply power and check that the LED’s
on the front of the 6094C PSU’s have illuminated green.

Document Number: 6004ÚM.doc Issue 10
15th November 2000
8
3. Specification
Mechanical
Height 178.00mm
Width 440.00mm
Depth 355.00mm
Weight (6004T) 12.55Kg’s
(6094C) 1.50Kg
Operating Temp 0°C to 40°C
Storage Temp -10°C to 60°C
Electrical
Fuse 6.3A Slow Blow 240Vac
Power Cord Straight 3 Pin Female IEC 320
250Vac 10A
125Vac 10A
Power Supply (6094C)
Input Voltage 90Vac -260Vac
Input Frequency 45 - 65 Hz
Power Factor >0.9
Earth Leakage <3mA
Output Voltage +6.5Vdc and -7.5Vdc
Output Current 1-34A (+6.5Vdc), 1-18A (-7.5Vdc)
Operating Temp 0°C to 40°C
Power 364W
Ripple & Noise <50mV (20MHz bandwidth)
MTBF >200000 Hrs (300W load at 40C)

Document Number: 6004ÚM.doc Issue 10
15th November 2000
9
Top View of 6094C Power Supply Module
Rear View of 6094C Power Supply Module
6094C PSU Rearconnector Pin Out
Row d Pin Function Row z Pin Function
6Power Fail 4+6.5Vdc
10 Gnd 8Gnd
14 I2C Data 12 -7.5Vdc
18 I2C Clock 16 +6.5Vdc
22 +6.5Vdc 20 Gnd
26 24 -7.5Vdc
30 Live 28 Neutral
32 Earth
Fuse
Fan
Led:
Green = Power Good
Red = Over Temp
Table of contents
Other Leitch Power Supply manuals
Popular Power Supply manuals by other brands

Xtralis
Xtralis VESDA VPS-VEA-115UL installation instructions

Antec
Antec HCP-1200 user manual

ABB
ABB NES4812-23-AC1-PS4-DC1E-LVBD quick start guide

Altronix
Altronix AL400ULPD8CB installation guide

Brähler Systems
Brähler Systems CDSVAN PSU04 operating instructions

Crystal Pressure
Crystal Pressure 24VC Loop Operation manual