2NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
TABLE OF CONTENTS
Packaging........................................ page 2
Introduction..................................... page 2
Massachusetts and New York
Requirements ................................ page 2
General Information......................... page 2
Location .......................................... page 3
Appliance Specifications.................. page 4
Clearances ....................................... page 4
Gas Vent Rule.................................. page 4
Framing Specifications .................... page 5
Assembly Steps............................... page 5
Installation....................................... page 6
Vent System Installation.................. page 7
Field Wiring ..................................... page 7
Connecting Gas Line........................ page 8
Outside Air Kit Installation ............... page 8
Log and Rockwool Installation ........ page 9
Appliance Operation ........................ page 10
Manual Limit Switch........................ page 10
Millivolt Appliance Checkout............ page 11
Electronic Appliance Checkout......... page 11
Adjustments .................................... page 11
Finishing Requirements................... page 12
Cold Climate Insulation.................... page 12
Installation Accessories................... page 12
Gas Conversion Kits.................. page 14
GENERAL INFORMATION
Note: Installation and repair should be per-
formedbyaqualifiedserviceperson.Theappli-
ance should be inspected annually by a quali-
fied professional service technician. More fre-
quent inspections and cleanings may be re-
quired due to excessive lint from carpeting,
bedding material, etc. It is imperative that the
control compartment, burners and circulating
airpassagewaysoftheappliancebekeptclean.
S'assurerquelebrùleuretlecompartimentdes
commandes sont propres. Voir les instruc-
tions d'installation et d'utilisation qui
accompagnent l'apareil.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
DO NOT ATTEMPT TO ALTER OR MODIFY
THECONSTRUCTIONOFTHEAPPLIANCEOR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATIONANDLISTINGSOFTHISUNIT.
These appliances are designed to operate on
naturalorpropanegasonly.Theuseofotherfuels
or combination of fuels will degrade the perfor-
mance of this system and may be dangerous.
Inputof appliance are45,000 BTU/HR forPro-
panemodelsand50,00BTU/HRforNaturalGas
models.
INTRODUCTION
The millivolt appliances are designed to oper-
ateoneithernaturalorpropanegas.Amillivolt
gas control valve with piezo ignition system
provides safe, efficient operation.
The electronic appliances are designed to op-
erate on either natural or propane gas. An
electronic intermittent pilot system provides
safe, efficient operation. External electrical
power is required to operate these units.
Theseappliancescomplywith NationalSafety
Standards and are tested and listed by Omni-
Test Laboratories (Report No. 116-F-45-5) to
ANSI Z21.50b (in Canada, CSA-2.22b), and
CAN/CGA-2.17-M91inboth USAand Canada,
as vented gas fireplaces.
Installation must conform to local codes. In
the absence of local codes, installation must
comply with the current National Fuel Gas
Code,ANSIZ223.1(NFPA54).(InCanada,the
currentCAN/CGAB149installationcode.)Elec-
tricalwiringmust complywithlocalcodes. In
the absence of local codes, installation must
be in accordance with the National Electrical
Code, NFPA 70 - (latest edition). (In Canada,
thecurrentCSAC22.1CanadianElectricCode.)
These Crestline series appliances have been
designed,testedand listedforusewithSecurity
Chimney's10"B-vent system. Refertopage12
for a complete listing of the 10" B-vent compo-
nents available for use with these models.
3 - one envelope containing the literature
packagewhichconsistsofthehomeowner's
manual, installation instructions, and war-
ranty;envelopeislocatedinthecontrolarea.
WARNING: THESE FIREPLACES ARE
VENTEDDECORATIVEGASAPPLIANCES.
DO NOT BURN WOOD OR OTHER MATE-
RIAL IN THESE APPLIANCES.
WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
ORPROPERTYDAMAGE. REFERTOTHIS
MANUAL. FOR ASSISTANCE OR ADDI-
TIONAL INFORMATION CONSULT A
QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.
PACKAGING
The assembled vented gas fireplace is pack-
aged with:
1 - onefoam packagedlog set located infire-
box area.
2 - one bag of glowing embers (rockwool)
located in the bottom compartment.
Massachusetts:
Installation of these fireplaces are approved
for installation in the US state of Massachu-
setts if the following additional requirements
are met-
• Installation and repair must be done by a
plumberorgasfitterlicensedintheCommon-
wealth of Massachusetts.
•Theflexiblegaslineconnectorusedshallnot
exceed 36 inches (92 centimeters) in length.
• The individual manual shut-off must be a T-
handle type valve.
New York City, NY:
Installation of these fireplaces are approved
forinstallationinNewYorkCityintheUSstate
of New York, if the following additional re-
quirements are met-
• An outside air kit (FOAK-4 or FOAK-4LD)
must be installed.
Massachusetts And New York City, NY
Requirements
Theseappliancesareapprovedforinstallation
in the following USA locations listed in the
following:
Gas Orifice Size
Type Elevation
0 - 4500'
(0 - 1370 m)
0 - 4500'
(0 - 1370 m)
Natural Propane
#26 #45
#45
LSBV-3628
LSBV-4228
#26
Thismanualispartofasetoftwosupporting
thisproduct. Refer to manual 875,035M for
Care & Operations.
Please read and understand these
instructions before beginning your
installation.